AIMTEC AMEL20-3.3SMAZ 20 watt | ac-dc / dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AMEL20-MAZ
20 Watt | AC-DC / DC-DC Converter
FEATURES:
 I/O Isolation 4000VAC
 Operating Temp: -40oC to +70oC
 Over load, Over Voltage, Short Circuit Protection
 Up to 83% efficiency


Energy Star compliant
Ultra small package
CB
Models
Single output
Model
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Max Output
wattage (W)
Output
Voltage(V)
Output
Current max
(A)
Efficiency
(%)
Maximum
capacitive
load
(µF)
AMEL20-3.3SMAZ
90-264/47-440
130-370
13.2
3.3
4
5600
AMEL20-5SMAZ
90-264/47-440
130-370
20
5
4
4700
AMEL20-12SMAZ
90-264/47-440
130-370
20
12
1.66
3300
AMEL20-15SMAZ
90-264/47-440
130-370
20
15
1.33
2200
AMEL20-24SMAZ
90-264/47-440
130-370
20
24
0.84
1000
Note: Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL20-5SMAZ-ST)
115
230
VAC
VAC
75
79
81
83
83
73
78
81
81
82
Models
Asymmetric Dual output
Model
AMEL20-3.35DMAZ
AMEL20-3.312DMAZ
AMEL20-3.315DMAZ
AMEL20-3.324DMAZ
AMEL20-512DMAZ
AMEL20-515DMAZ
AMEL20-524DMAZ
AMEL20-1215DMAZ
AMEL20-1224DMAZ
AMEL20-1524DMAZ
Input Voltage
(VAC/Hz)
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
Input
Voltage
(VDC)
Max Output
wattage (W)
130-370
130-370
130-370
130-370
130-370
130-370
130-370
130-370
130-370
130-370
17.5
18
18
18
18
18
18
18
18
18
Output
Voltage
(V)
3.3/5
3.3/12
3.3/15
3.3/24
5/12
5/15
5/24
12/15
12/24
15/24
Rated
Output
Current (A)
Efficiency
(%)
Maximum
capacitive
load
(µF)
1.4/2.5
1.4/1.1
1.4/0.89
1.4/0.55
1.6/0. 83
1.6/0.66
1.6/0.46
0.66/0.66
0.58/0. 42
0.54/0. 42
1000
1000
1000
1000
680
680
680
560
560
560
AMEL20-3.3N5DMAZ
90-264/47-440
130-370
14.8
-3.3/5
-0.7/2.5
680
AMEL20-3.3N12DMAZ
90-264/47-440
130-370
18
-3.3/12
-1.4/1.1
680
AMEL20-3.3N15DMAZ
90-264/47-440
130-370
18
-3.3/15
-1.4/0.89
680
AMEL20-5N5DMAZ
90-264/47-440
130-370
14
-5/5
-0.8/2
680
AMEL20-5N12DMAZ
90-264/47-440
130-370
18
-5/12
-1.6/0. 83
470
AMEL20-5N15DMAZ
90-264/47-440
130-370
18
-5/15
-1.6/0.66
470
AMEL20-12N12DMAZ
90-264/47-440
130-370
18
-12/12
-0.66/0.83
470
AMEL20-12N15DMAZ
90-264/47-440
130-370
18
-12/15
-0.66/0.66
330
Note: Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL20-5SMAZ-ST)
115
230
VAC
VAC
75
78
77
76
76
78
76
77
79
80
76
78
77
76
77
79
77
78
80
81
75
76
76
75
75
75
77
76
76
77
77
76
76
76
78
77
*Output power must not exceed the listed values
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
www.aimtec.com
F 052e R8.V
Conditions
Typical
115VAC
230VAC
115VAC
230VAC


Tel: +1 514 620 2722
1 of 6
Maximum
500
350
30
50
Units
mA
mA
A
A
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-MAZ
20 Watt | AC-DC / DC-DC Converter
Input Specifications (continued)
Parameters
Leakage current
External fuse
Input dissipation
Start up time
Conditions
Typical
Recommended slow blow type
110/230Vac

1.5
൑0.4
50
Conditions
Typical
Maximum
0.25
Units
mA
A
W
ms
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Load regulation (dual output)
Transient recovery time
Transient response deviation
Ripple & Noise*
Hold-up time
Maximum
±2
±1
±2
±3
500
±2
75
100
10
25
0-100% load
Unbalanced (0-100%) load
25% load step
3.3 & 5V models
12, 15 & 24V models
110VAC
230VAC
Units
%
%
%
%
µs
% of Vout
mV p-p
ms
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) and 47µF (E/C) parallel capacitor.
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Conditions
Typical
60 sec
Rated
Units
4000
VAC
MΩ
Maximum
Units
>1000
General Specifications
Parameters
Switching frequency
Over load protection
Over voltage protection
Short circuit protection
Protection class
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Conditions
Typical
65
150
Zener Diode Clamp
Auto recovery
Class II
-40 to +70
Foldback
See derating table
KHz
%
oC
100
oC
oC
-45 to +95
±0.02
% / oC
Free air convection
Non condensing
20 ~ 95
% RH
Plastic (flammability to UL 94V-0)
70
g
2.22 x 1.21 x 0.99 inches
56.48 x 30.86 x 25.10mm
> 400 000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
> 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load
Environment Approval
Test
Shock
Vibration
Parameters
Wave form
Acceleration amplitude
Bump duration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
Conditions
Half sine wave
5gn
30 ms
before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine
1mm
3g
10-100Hz, speed 0.05Hz/s
Converter operation
www.aimtec.com
F 052e R8.V
Tel: +1 514 620 2722
2 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-MAZ
20 Watt | AC-DC / DC-DC Converter
Safety Specifications
Parameters
Agency approvals
cULus, CE, CB
Medical Electrical Equipment
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Information Technology Equipment
Information Technology Equipment
Standards
IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No.
601.1-M90
EN 60950-1:2006+A11:2009
EN55011, class B
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 2
IEC 61000-4-4 Level 2
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 2
IEC 61000-4-8
IEC 61000-4-11
UL 60950-1:2007
CAN/CSA-C22.2 No.60950-1-07
Additional Surge Protective Circuitry
The AMEL20-MAZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However
greater protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal
Oxide Varistor) device example TVR10471KSY to the N / L input lines 2KV surge protection or greater, can be achieved.
MOV PN
Vrms
V
Vdc
V
Wmax (2ms)
J
Pmax
W
TVR10471KSY
300
385
70
0.4
Pin Out Specifications
Pin
Single
Dual positive
Dual negative/positive
1
2
3
4
5
AC Input (N)
AC Input (L)
+V Output
-V Output
No pin
AC Input (N)
AC Input (L)
+V1 Output
Common
+V2 Output
AC Input (N)
AC Input (L)
+V1 Output
Common
-V2 Output
www.aimtec.com
F 052e R8.V
Tel: +1 514 620 2722
3 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-MAZ
20 Watt | AC-DC / DC-DC Converter
Dimensions
56.46
(2.22)
45.72
(1.80)
3
1
4
3
1
4
2
5
5.37
(0.21)
2
5.37
(0.21)
5
DIV: 10.00 (0.40)
5Ø 1.0 (Ø 0.04)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter 1.0 ± 0.05 (0.04 ± 0.002)
Pin Pitch Tolerance ±0.35 (±0.014)
1.05
(0.04)
Output Power (%)
Derating
www.aimtec.com
F 052e R8.V
Tel: +1 514 620 2722
4 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-MAZ
20 Watt | AC-DC / DC-DC Converter
Output Power (%)
Derating (Dual Output Models)
www.aimtec.com
F 052e R8.V
Tel: +1 514 620 2722
5 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL20-MAZ
20 Watt | AC-DC / DC-DC Converter
Dimensions of Optional ST Mounting Plate Version
38.00
25.00
Pin Out Specification ST Version
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary
based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C,
humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all
internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for
release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications
which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available
at www.aimtec.com.
www.aimtec.com
F 052e R8.V
Tel: +1 514 620 2722
6 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages