Battery BP13-6FRH Vrla rechargeable battery Datasheet

VRLA Rechargeable Battery
Measures
BP13-6 H (BP13-6FR H)
FEATURES
Technology
Values
Innovation
APPLICATION
Maintenance free(no water topping-up required).
No free acid(Non-spillable battery).
Low self-discharge rate, lower than 3% capacity
loss per month.
Can be used in any orientation(excluding used inverted).
UPS
Electronic Toy-Cars
Emergency Lights
Rechargeable Flash Lights
Fans
SPECIFICATIONS
Nominal Voltage
Nominal Capacity
Approx. Weight
6V
Terminals
Internal Resistance
Max. Discharge Current
Type H
ISO 9001
13.0Ah @ 20 hour rate F.V.(1.75V/cell)
2500g(5.51lbs.)
9m
ISO14001
(Fully Charged )
UL
30 A (5 sec.)
Max. Charge Current
3.9 A
Charge 0oC~40oC(32oF~104oF)
Discharge -20oC~50oC(-4oF~122oF)
Storage. -20oC~40oC(-4oF~104oF)
Operating Temperature Range
Container Material
IEC61056
JIS C 8702
GB/T 19639
ABS(UL94-HB, UL94-V0 is optional)
DIMENSION(mm/inch)
OUTER DIMENSIONS
TERMINAL TYPE
Length
Terminal H
108±1.5 (4.25±0.06)
Width
31.4(0.84)
Container Height
140±1.5 (5.51±0.06)
Total Height
140±1.5 (5.51±0.06)
o
o
Constant power discharge characteristics at 25 C/77 F
15.6(0.61)
9.5(0.37)
71±1.5 (2.80±0.06)
Discharge
Time
CE
Unit: W
15 Min
30 Min
1 Hr
3 Hr
5 Hr
10 Hr
20 Hr
1.80V
138.6
82.5
47.3
18.9
13.06
7.30
3.84
1.75V
145.0
85.6
48.7
19.3
13.26
7.41
3.90
1.70V
149.5
87.6
49.6
19.5
13.33
7.45
3.92
1.65V
152.9
88.8
50.2
19.6
13.38
7.47
3.93
1.60V
156.0
89.7
50.7
19.8
13.42
7.47
3.93
F.V.
(V/cell)
o
o
Constant current discharge characteristics at 25 C/77 F
Discharge
Time
Unit: A
15 Min
30 Min
1 Hr
3 Hr
5 Hr
10 Hr
20 Hr
1.80V
24.1
14.0
7.95
3.16
2.177
1.217
0.640
1.75V
25.2
14.5
8.19
3.22
2.210
1.235
0.650
1.70V
26.0
14.8
8.34
3.25
2.222
1.241
0.653
1.65V
26.6
15.1
8.44
3.27
2.230
1.245
0.655
1.60V
27.1
15.2
8.52
3.29
2.237
1.245
0.655
F.V.
(V/cell)
All data shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto.
A/0
REV. Jul. 2009
Powered by