Infineon BAS16 Silicon switching diode Datasheet

BAS16...
Silicon Switching Diode
• For high-speed switching applications
BAS16
BAS16W
BAS16-02L
BAS16-02V
BAS16-02W
BAS16-03W
BAS16S
BAS16U
6
3
4
5
D 1
1
1
4
D 2
3
D 3
D 1
2
1
2
Type
BAS16
BAS16-02L*
BAS16-02V
BAS16-02W
BAS16-03W
BAS16-07L4*
BAS16S
BAS16U
BAS16W
BAS16-07L4
2
3
1
Package
SOT23
TSLP-2-1
SC79
SCD80
SOD323
TSLP-4-4
SOT363
SC74
SOT323
D 2
2
Configuration
single
single, leadless
single
single
single
parallel pair, leadless
parallel triple
parallel triple
single
Marking
A6s
A6
6
A6
B
6A
A6s
A6s
A6s
* Preliminary Data
1
Dec-04-2003
BAS16...
Maximum Ratings at TA = 25°C, unless otherwise specified
Parameter
Symbol
Diode reverse voltage
VR
80
Peak reverse voltage
VRM
85
Forward current
IF
Value
250
BAS16-02L, -07L4
200
BAS16-02V, -02W
200
BAS16-03W
250
BAS16S
200
BAS16U
200
BAS16W
250
A
IFSM
t = 1 µs, BAS16/ S/ U/ W/ -03W
4.5
t = 1 µs, BAS16-02L/ -02V/ -02W/ -07L4
2.5
t=1s
0.5
Total power dissipation
V
mA
BAS16
Non-repetitive peak surge forward current
Unit
mW
Ptot
BAS16, TS ≤ 54 °C
370
BAS16-02L, -07L4, TS ≤ 130 °C
250
BAS16-02V, -02W, TS ≤ 120 °C
250
BAS16-03W, TS ≤ 116 °C
BAS16S, TS ≤ 85 °C
250
BAS16U, TS ≤ 113 °C
250
BAS16W, TS ≤ 119 °C
250
250
Junction temperature
Tj
Storage temperature
Tstg
2
150
°C
-65 ... 150
Dec-04-2003
BAS16...
Thermal Resistance
Parameter
Symbol
Junction - soldering point 1)
RthJS
Value
Unit
K/W
BAS16, BAS16S
≤ 260
BAS16-02L, -07L4
≤ 80
BAS16-02V, -02W
≤ 120
BAS16-03W
≤ 135
BAS16U
≤ 150
BAS16W
≤ 125
Electrical Characteristics at TA = 25°C, unless otherwise specified
Symbol
Values
Parameter
min.
typ. max.
DC Characteristics
85
Breakdown voltage
V(BR)
Unit
V
I(BR) = 100 µA
Reverse current
IR
µA
VR = 75 V
-
-
0.1
VR = 25 V, TA = 150 °C
-
-
30
VR = 75 V, TA = 150 °C
-
-
50
Forward voltage
mV
VF
IF = 1 mA
-
-
715
IF = 10 mA
-
-
855
IF = 50 mA
-
-
1000
IF = 100 mA
-
-
1200
IF = 150 mA
-
-
1250
-
-
1.75
Forward recovery voltage
Vfr
V
IF = 10 mA, tP = 20 ns
1For
calculation of RthJA please refer to Application Note Thermal Resistance
3
Dec-04-2003
BAS16...
Electrical Characteristics at TA = 25°C, unless otherwise specified
Symbol
Values
Unit
Parameter
min.
typ. max.
AC Characteristics
2
pF
Diode capacitance
CT
VR = 0 V, f = 1 MHz
Reverse recovery time
trr
-
-
4
ns
IF = 10 mA, IR = 10 mA, measured at IR = 1mA ,
RL = 100 Ω
Test circuit for reverse recovery time
Pulse generator: tp = 100ns, D = 0.05, tr = 0.6ns,
R i = 50Ω
D.U.T.
ΙF
Oscillograph
Oscillograph: R = 50Ω, tr = 0.35ns, C = 0.05pF
EHN00017
4
Dec-04-2003
BAS16...
Reverse current IR = ƒ (TA)
Forward Voltage VF = ƒ (TA)
IF = Parameter
VR = Parameter
10 5
1.0
BAS 16
EHB00025
nA
V
VF
Ι F = 100 mA
10 4
IR
10 mA
10 3
1 mA
0.5
0.1 mA
70 V
25 V
10 2
10 1
0
25
50
75
100
°C
0
150
0
TA
50
100
Forward current IF = ƒ (VF)
Forward current IF = ƒ (T S)
TA = 25°C
BAS16
150
BAS 16
C
TA
150
300
EHB00023
Ι F mA
mA
200
IF
100
typ
150
max
100
50
50
0
0
0.5
1.0
V
0
0
1.5
15
30
45
60
75
90 105 120 °C
150
TS
VF
5
Dec-04-2003
BAS16...
Forward current IF = ƒ (T S)
Forward current IF = ƒ (T S)
BAS16-02L, -07L4
BAS16-02V, -02W
250
250
mA
IF
IF
mA
150
150
100
100
50
50
0
0
15
30
45
60
75
90 105 120 °C
0
0
150
15
30
45
60
75
90 105 120 °C
TS
150
TS
Forward current IF = ƒ (T S)
Forward current IF = ƒ (T S)
BAS16-03W
BAS16S
250
300
mA
mA
IF
IF
200
150
150
100
100
50
50
0
0
15
30
45
60
75
90 105 120 °C
0
0
150
15
30
45
60
75
90 105 120 °C
150
TS
TS
6
Dec-04-2003
BAS16...
Forward current IF = ƒ (T S)
Forward current IF = ƒ (T S)
BAS16U
BAS16W
250
300
mA
mA
IF
IF
200
150
150
100
100
50
0
0
50
15
30
45
60
90 105 120 °C
75
0
0
150
15
30
45
60
90 105 120 °C
75
TS
150
TS
Permissible Puls Load R thJS = ƒ (tp)
BAS16
Permissible Pulse Load
IFmax / I FDC = ƒ (t p)
BAS16
10 3
10 2
IFmax/IFDC
K/W
RthJS
10 2
0.5
0.2
0.1
0.05
0.02
0.01
0.005
D=0
10 1
10 0
10 -1 -7
10
10
-6
10
-5
10
-4
10
D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5
10 1
-3
10
-2
s
10
10 0 -7
10
0
tp
10
-6
10
-5
10
-4
10
-3
10
-2
s
10
0
tp
7
Dec-04-2003
BAS16...
Permissible Puls Load R thJS = ƒ (tp)
BAS16-02L, -07L4
Permissible Pulse Load
IFmax / I FDC = ƒ (t p)
BAS16-02L, -07L4
10 2
I Fmax/ I FDC
10
2
R thJS
K/W
0.5
0.2
0.1
0.05
0.02
0.01
0.005
D=0
10 1
10 0 -6
10
10
-5
10
-4
10
-3
-
D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5
10 1
10
-2
10
-1
s
10
10 0 -6
10
1
10
-5
10
-4
10
-3
10
-2
s
tp
10
0
-3
10
-2
s
10
0
tp
Permissible Puls Load R thJS = ƒ (tp)
BAS16-02V, -02W
Permissible Pulse Load
IFmax / I FDC = ƒ (t p)
BAS16-02V, -02W
10 2
10 3
IFmax/ IFDC
RthJS
K/W
10 2
D=0.5
0.2
0.1
0.05
0.02
0.01
0.005
0
10 1
10 0 -6
10
10
-5
10
-4
10
-3
10
-2
D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5
10 1
s
10
10 0 -6
10
0
tp
10
-5
10
-4
10
tp
8
Dec-04-2003
BAS16...
Permissible Puls Load R thJS = ƒ (tp)
BAS16-03W
Permissible Pulse Load
IFmax / I FDC = ƒ (t p)
BAS16-03W
10
10 2
3
I Fmax/ I FDC
R thJS
K/W
10 2
D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5
10 1
D=0.5
0.2
0.1
0.05
0.02
0.01
0.005
0
10 1
10 0 -6
10
10
-5
10
-4
10
-3
10
-2
s
10
10 0 -6
10
0
10
-5
10
-4
10
-3
10
-2
tp
s
10
0
10
0
tp
Permissible Puls Load R thJS = ƒ (tp)
BAS16S
Permissible Pulse Load
IFmax / I FDC = ƒ (t p)
BAS16S
10 2
10 3
IFmax/ IFDC
RthJS
K/W
10 2
10 0 -6
10
10
-5
10
-4
10
-3
10
D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5
10 1
D=0.5
0.2
0.1
0.05
0.02
0.01
0.005
0
10 1
-
-2
s
10
10 0 -6
10
0
tp
10
-5
10
-4
10
-3
10
-2
s
tp
9
Dec-04-2003
BAS16...
Permissible Puls Load R thJS = ƒ (tp)
BAS16U
Permissible Pulse Load
IFmax / I FDC = ƒ (t p)
BAS16U
10
10 2
3
I Fmax/ I FDC
R thJS
K/W
10 2
D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5
10 1
D=0.5
0.2
0.1
0.05
0.02
0.01
0.005
0
10 1
10 0 -6
10
10
-5
10
-4
10
-3
10
-2
s
10
10 0 -6
10
0
10
-5
10
-4
10
-3
10
-2
tp
s
10
0
10
0
tp
Permissible Puls Load R thJS = ƒ (tp)
BAS16W
Permissible Pulse Load
IFmax / I FDC = ƒ (t p)
BAS16W
10 2
10 3
IFmax/ IFDC
RthJS
K/W
10 2
-
D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5
10 1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
D=0
10 1
10 0 -6
10
10
-5
10
-4
10
-3
10
-2
s
10
10 0 -6
10
0
tp
10
-5
10
-4
10
-3
10
-2
s
tp
10
Dec-04-2003
Similar pages