Mean Well CEN-75-30 75w single output led power supply Datasheet

CEN-75
75W Single Output LED Power Supply
series
½ Features :
Universal AC input / Full range (up to 295VAC)
Protections: Short circuit / Over current / Over voltage / Over temperature
Output voltage and constant current level adjustable
Built-in active PFC function
IP66 design for indoor or outdoor installations
Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
110
F
M
M
IP66
SELV
SPECIFICATION
MODEL
DC VOLTAGE
CEN-75-15
CEN-75-20
CEN-75-24
CEN-75-30
CEN-75-36
CEN-75-42
CEN-75-48
CEN-75-54
15V
20V
24V
30V
36V
42V
48V
54V
15 ~ 20V
18 ~ 24V
22.5 ~ 30V
27 ~ 36V
31.5 ~ 42V
36 ~ 48V
40.5 ~ 54V
RATED CURRENT
5A
3.75A
3.15A
2.5A
2.1A
1.8A
1.57A
1.4A
CURRENT RANGE
0 ~ 5A
0 ~ 3.75A
0 ~ 3.15A
0 ~ 2.5A
0 ~ 2.1A
0 ~ 1.8A
0 ~ 1.57A
0 ~ 1.4A
RATED POWER
75W
75W
75.6W
75W
75.6W
75.6W
75.36W
75.6W
RIPPLE & NOISE (max.) Note.2 2.7Vp-p
2Vp-p
2.7Vp-p
3Vp-p
3.6Vp-p
4Vp-p
4.6Vp-p
5Vp-p
VOLTAGE ADJ. RANGE (SVR1) 13.5 ~ 17V
17 ~ 22V
22 ~ 27V
27 ~ 33V
33 ~ 40V
37 ~ 46V
43 ~ 53V
49 ~ 58V
CURRENT ADJ. RANGE(SVR2) 3.75 ~ 5A
2.81 ~ 3.75A
2.36 ~ 3.15A
1.88 ~ 2.5A
1.58 ~ 2.1A
1.35 ~ 1.8A
1.18 ~ 1.57A
1.05 ~ 1.4A
CONSTANT CURRENT OPERATION VOLTAGE Note.5 11.25 ~ 15V
OUTPUT
VOLTAGE TOLERANCE Note.3
10%
LINE REGULATION
3.0%
5.0%
LOAD REGULATION
1400ms / 230VAC 2800ms / 115VAC at full load
SETUP TIME
VOLTAGE RANGE
INPUT
Note.4 90 ~ 295VAC
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
87%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.1A/115VAC
45A/230VAC
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY &
EMC
NOTE
88%
89%
0.55A/230VAC
90%
90%
90%
91%
91%
54 ~ 60V
59 ~ 65V
0.4A/277VAC
<0.75mA / 240VAC
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
17.5 ~ 21V
22.8 ~ 26V
28 ~ 34V
34 ~ 38V
41 ~ 46V
47 ~ 52V
Protection type : Shut down o/p voltage, re-power on to recover
85
10
(RTH1)
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +70
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 50
)
SAFETY STANDARDS
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL879, UL8750, CSA C22.2 No.207-M89, CSA C22.2 No.250.0-08, TUV EN61347-1, EN61347-2-13, IP66, J61347-1, J61347-2-13 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
EMC EMISSION
Compliance to EN55015, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
EMC IMMUNITY
MTBF
OTHERS
127 ~ 417VDC
FREQUENCY RANGE
DIMENSION
PACKING
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), criteria A
522.2Khrs min. MIL-HDBK-217F (25 )
185*62.5*40.5mm (L*W*H)
0.56Kg;24pcs/14.4Kg/1.11CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 75% ~ 100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:CEN-75-SPEC 2012-03-20
CEN-75
75W Single Output LED Power Supply
Mechanical Specification
Case No.993B
series
Unit:mm
185
10.5
164
7.6
300 20
T case
300 20
Vo
Io
ADJ. ADJ.
81
31.25
30.6
45
62.5
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
SJTW 18AWG 3C
+V(Red)
-V(Black)
SVT 18AWG 2C
4.6 4PL
40.5
T case: Max. Case Temperature.
Block Diagram
fosc : 50KHz(115VAC)
75KHz(230VAC)
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
FG
+V
-V
DETECTION
CIRCUIT
O.L.P.
PWM & PFC
CONTROL
O.C.P.
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-30
-25
-5
0
15
30
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
295
INPUT VOLTAGE (V) 60Hz
File Name:CEN-75-SPEC 2012-03-20
CEN-75
75W Single Output LED Power Supply
series
Power Factor Characteristic
PF
Constant Current Mode
1 .0 0
0 .9 8
0 .9 6
0 .9 4
0 .9 2
0 .9 0
0 .8 8
0 .8 6
0 .8 4
0 .8 2
0 .8 0
0 .7 8
277V ac
230V ac
115V ac
50%
60%
70%
80%
90%
100%
(75W)
LOAD
EFFICIENCY vs LOAD (48V Model)
CEN-75 series possess superior working efficiency that up to 91% can be reached in field applications.
94
90
EFFICIENCY (%)
86
82
78
277Vac
74
230Vac
70
115Vac
66
62
58
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DRIVING METHODS OF LED MODULE
This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.
100
Vo(%)
Constant
Current area
75
(max.)
Hiccup
Protection
50
100
Io (%)
Typical LED power supply I-V curve
File Name:CEN-75-SPEC 2012-03-20
Similar pages