ADPOW APT60D40LCT Ultrafast soft recovery rectifier diode Datasheet

400V 2x60A
APT60D40LCT
APT60D40LCTG*
®
*G Denotes RoHS Compliant, Pb Free Terminal Finish.
ULTRAFAST SOFT RECOVERY RECTIFIER DIODE
PRODUCT APPLICATIONS
PRODUCT FEATURES
PRODUCT BENEFITS
• Anti-Parallel Diode
-Switchmode Power Supply
-Inverters
• Free Wheeling Diode
-Motor Controllers
-Converters
-Inverters
• Snubber Diode
• Ultrafast Recovery Times
• Low Losses
• Soft Recovery Characteristics
• Low Noise Switching
• Popular TO-264 Package
• Cooler Operation
• Low Forward Voltage
• Higher Reliability Systems
• Low Leakage Current
• Increased System Power
Density
• PFC
TO
-
26
1
2
4
3
1
3
2
1 - Anode 1
2 - Common Cathode
Back of Case - Cathode
3 - Anode 2
MAXIMUM RATINGS
Symbol
VR
All Ratings Per Leg: TC = 25°C unless otherwise specified.
Characteristic / Test Conditions
Maximum Peak Repetitive Reverse Voltage
VRWM
Maximum Working Peak Reverse Voltage
IF(AV)
Maximum Average Forward Current (TC = 140°C, Duty Cycle = 0.5)
IFSM
TJ,TSTG
TL
UNIT
400
Volts
Maximum D.C. Reverse Voltage
VRRM
IF(RMS)
APT60D40LCT(G)
60
RMS Forward Current (Square wave, 50% duty)
146
Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms)
600
Amps
-55 to 175
Operating and StorageTemperature Range
°C
300
Lead Temperature for 10 Sec.
STATIC ELECTRICAL CHARACTERISTICS
Forward Voltage
IRM
Maximum Reverse Leakage Current
CT
Junction Capacitance, VR = 200V
MIN
TYP
MAX
IF = 60A
1.3
1.5
IF = 120A
1.6
IF = 60A, TJ = 125°C
1.2
Volts
VR = VR Rated
250
VR = VR Rated, TJ = 125°C
500
APT Website - http://www.advancedpower.com
120
UNIT
µA
4-2005
VF
Characteristic / Test Conditions
pF
053-4016 Rev B
Symbol
APT60D40LCT(G)
DYNAMIC CHARACTERISTICS
Symbol
Characteristic
Test Conditions
trr
Reverse Recovery Time
trr
Reverse Recovery Time
Qrr
Reverse Recovery Charge
IRRM
IF = 1A, diF/dt = -100A/µs, VR = 30V, TJ = 25°C
Reverse Recovery Time
Qrr
Reverse Recovery Charge
IF = 60A, diF/dt = -200A/µs
VR = 266V, TC = 125°C
Maximum Reverse Recovery Current
trr
Reverse Recovery Time
Qrr
Reverse Recovery Charge
IRRM
VR = 266V, TC = 25°C
Maximum Reverse Recovery Current
trr
IRRM
IF = 60A, diF/dt = -200A/µs
IF = 60A, diF/dt = -800A/µs
VR = 266V, TC = 125°C
Maximum Reverse Recovery Current
MIN
TYP
MAX
UNIT
-
30
-
37
-
80
-
4
-
110
ns
-
540
nC
-
10
-
65
ns
-
1050
nC
-
27
Amps
MIN
TYP
ns
nC
-
-
Amps
Amps
THERMAL AND MECHANICAL CHARACTERISTICS
Symbol
Characteristic / Test Conditions
MAX
RθJC
Junction-to-Case Thermal Resistance
.34
RθJA
Junction-to-Ambient Thermal Resistance
40
WT
Torque
Package Weight
oz
5.9
g
10
lb•in
1.1
N•m
APT Reserves the right to change, without notice, the specifications and information contained herein.
0.9
0.7
0.20
0.5
Note:
0.15
0.3
0.10
t2
0.1
SINGLE PULSE
0.05
10
-5
Duty Factor D = 1/t2
Peak TJ = PDM x ZθJC + TC
10
10-3
10-2
10-1
1.0
RECTANGULAR PULSE DURATION (seconds)
FIGURE 1a. MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs. PULSE DURATION
-4
RC MODEL
4-2005
Junction
temp (°C)
053-4016 Rev B
t1
t
0.05
0
PDM
Z JC, THERMAL IMPEDANCE (°C/W)
θ
0.35
0.25
0.129 °C/W
0.0107 J/°C
0.211 °C/W
0.120 J/°C
Power
(watts)
Case temperature (°C)
FIGURE 1b, TRANSIENT THERMAL IMPEDANCE MODEL
°C/W
0.22
Maximum Mounting Torque
0.30
UNIT
TYPICAL PERFORMANCE CURVES
180
120
100
80
TJ = 125°C
40
TJ = 150°C
20
0
TJ = 25°C
0
Qrr, REVERSE RECOVERY CHARGE
(nC)
1400
T = 125°C
J
V = 266V
R
1200
120A
1000
60A
800
600
30A
400
200
0
0
200
400
600
800
1000
-diF /dt, CURRENT RATE OF CHANGE (A/µs)
Figure 4. Reverse Recovery Charge vs. Current Rate of Change
1.2
trr
1.0
120A
R
120
60A
100
30A
80
60
40
0
0
200
400
600
800
1000
-diF /dt, CURRENT RATE OF CHANGE(A/µs)
Figure 3. Reverse Recovery Time vs. Current Rate of Change
30
T = 125°C
J
V = 266V
R
25
120A
20
60A
15
30A
10
5
0
0
200
400
600
800
1000
-diF /dt, CURRENT RATE OF CHANGE (A/µs)
Figure 5. Reverse Recovery Current vs. Current Rate of Change
180
Qrr
Duty cycle = 0.5
T = 175°C
160
J
140
IRRM
0.8
IF(AV) (A)
120
trr
0.6
0.4
100
80
60
Qrr
0.2
0.0
T = 125°C
J
V = 266V
20
TJ = -55°C
0.5
1
1.5
2
VF, ANODE-TO-CATHODE VOLTAGE (V)
Figure 2. Forward Current vs. Forward Voltage
Kf, DYNAMIC PARAMETERS
(Normalized to 800A/µs)
trr, REVERSE RECOVERY TIME
(ns)
140
IRRM, REVERSE RECOVERY CURRENT
(A)
IF, FORWARD CURRENT
(A)
160
60
APT60D40LCT(G)
140
40
20
0
25
50
75
100
125
150
TJ, JUNCTION TEMPERATURE (°C)
Figure 6. Dynamic Parameters vs. Junction Temperature
0
25
50
75
100
125
150
175
Case Temperature (°C)
Figure 7. Maximum Average Forward Current vs. CaseTemperature
700
600
500
400
4-2005
300
200
100
0
1
10
100 200
VR, REVERSE VOLTAGE (V)
Figure 8. Junction Capacitance vs. Reverse Voltage
053-4016 Rev B
CJ, JUNCTION CAPACITANCE
(pF)
800
APT60D40LCT(G)
Vr
diF /dt Adjust
+18V
APT30M30LLL
0V
D.U.T.
30µH
trr/Qrr
Waveform
PEARSON 2878
CURRENT
TRANSFORMER
Figure 9. Diode Test Circuit
1
IF - Forward Conduction Current
2
diF /dt - Rate of Diode Current Change Through Zero Crossing.
3
IRRM - Maximum Reverse Recovery Current.
4
trr - Reverse Recovery Time, measured from zero crossing where diode
current goes from positive to negative, to the point at which the straight
line through IRRM and 0.25 IRRM passes through zero.
5
1
4
Zero
5
3
2
Qrr - Area Under the Curve Defined by IRRM and trr.
Figure 10, Diode Reverse Recovery Waveform and Definitions
TO-264 (LCT) Package Outline
e1 SAC: Tin, Silver, Copper
4.60 (.181)
5.21 (.205)
1.80 (.071)
2.01 (.079)
19.51 (.768)
20.50 (.807)
3.10 (.122)
3.48 (.137)
Common Cathode
5.79 (.228)
6.20 (.244)
25.48 (1.003)
26.49 (1.043)
2.29 (.090)
2.69 (.106)
053-4016 Rev B
4-2005
19.81 (.780)
21.39 (.842)
2.29 (.090)
2.69 (.106)
Anode 1
Common Cathode
Anode 2
0.48 (.019)
0.84 (.033)
2.59 (.102)
3.00 (.118)
0.76 (.030)
1.30 (.051)
2.79 (.110)
3.18 (.125)
5.45 (.215) BSC
2-Plcs.
Dimensions in Millimeters and (Inches)
APT’s products are covered by one or more of U.S.patents 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522