AD AD590MF 2-terminal ic temperature transducer Datasheet

2-Terminal IC
Temperature Transducer
AD590
FEATURES
PIN CONFIGURATIONS
Linear current output: 1 μA/K
Wide temperature range: −55°C to +150°C
Probe-compatible ceramic sensor package
2-terminal device: voltage in/current out
Laser trimmed to ±0.5°C calibration accuracy (AD590M)
Excellent linearity: ±0.3°C over full range (AD590M)
Wide power supply range: 4 V to 30 V
Sensor isolation from case
Low cost
NC 1
NC
–
00533-024
+
NC 4
5
NC
NC = NO CONNECT
00533-001
7 NC
TOP VIEW
V– 3 (Not to Scale) 6 NC
Figure 1. 2-Lead FLATPACK
Figure 2. 8-Lead SOIC
–
GENERAL DESCRIPTION
The AD590 is a 2-terminal integrated circuit temperature transducer that produces an output current proportional to absolute
temperature. For supply voltages between 4 V and 30 V, the device
acts as a high impedance, constant current regulator passing
1 μA/K. Laser trimming of the chip’s thin-film resistors is used
to calibrate the device to 298.2 μA output at 298.2 K (25°C).
00533-025
+
Figure 3. 3-Pin TO-52
The AD590 should be used in any temperature-sensing
application below 150°C in which conventional electrical
temperature sensors are currently employed. The inherent
low cost of a monolithic integrated circuit combined with the
elimination of support circuitry makes the AD590 an attractive
alternative for many temperature measurement situations.
Linearization circuitry, precision voltage amplifiers, resistance
measuring circuitry, and cold junction compensation are not
needed in applying the AD590.
PRODUCT HIGHLIGHTS
In addition to temperature measurement, applications include
temperature compensation or correction of discrete components,
biasing proportional to absolute temperature, flow rate measurement, level detection of fluids and anemometry. The AD590 is
available in chip form, making it suitable for hybrid circuits and
fast temperature measurements in protected environments.
The AD590 is particularly useful in remote sensing applications.
The device is insensitive to voltage drops over long lines due to
its high impedance current output. Any well-insulated twisted
pair is sufficient for operation at hundreds of feet from the
receiving circuitry. The output characteristics also make the
AD590 easy to multiplex: the current can be switched by a
CMOS multiplexer, or the supply voltage can be switched by a
logic gate output.
8
V+ 2
1.
The AD590 is a calibrated, 2-terminal temperature sensor
requiring only a dc voltage supply (4 V to 30 V). Costly
transmitters, filters, lead wire compensation, and linearization circuits are all unnecessary in applying the device.
2.
State-of-the-art laser trimming at the wafer level in
conjunction with extensive final testing ensures that
AD590 units are easily interchangeable.
3.
Superior interface rejection occurs because the output is a
current rather than a voltage. In addition, power
requirements are low (1.5 mW @ 5 V @ 25°C). These
features make the AD590 easy to apply as a remote sensor.
4.
The high output impedance (>10 MΩ) provides excellent
rejection of supply voltage drift and ripple. For instance,
changing the power supply from 5 V to 10 V results in only
a 1 μA maximum current change, or 1°C equivalent error.
5.
The AD590 is electrically durable: it withstands a forward
voltage of up to 44 V and a reverse voltage of 20 V.
Therefore, supply irregularities or pin reversal does not
damage the device.
Rev. E
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113 ©2006–2009 Analog Devices, Inc. All rights reserved.
AD590
TABLE OF CONTENTS
Features .............................................................................................. 1
Product Description ..........................................................................6
General Description ......................................................................... 1
Explanation of Temperature Sensor Specifications ..................7
Pin Configurations ........................................................................... 1
Calibration Error ...........................................................................7
Product Highlights ........................................................................... 1
Error vs. Temperature: Calibration Error Trimmed Out .........7
Revision History ............................................................................... 2
Error vs. Temperature: No User Trims .......................................7
Specifications..................................................................................... 3
Nonlinearity ...................................................................................7
AD590J and AD590K Specifications ......................................... 3
Voltage and Thermal Environment Effects ...............................8
AD590L and AD590M Specifications ....................................... 4
General Applications...................................................................... 10
Absolute Maximum Ratings............................................................ 5
Outline Dimensions ....................................................................... 13
ESD Caution .................................................................................. 5
Ordering Guide .......................................................................... 14
REVISION HISTORY
9/09—Rev. D to Rev. E
Changes to Product Description Section ...................................... 6
Updated Outline Dimensions ....................................................... 13
Changes to Ordering Guide .......................................................... 14
1/06—Rev. C to Rev. D
Updated Format .................................................................. Universal
Changes to Figure 4 Equation ......................................................... 4
9/03—Rev. B to Rev. C
Added SOIC-8 Package...................................................... Universal
Change to Figure 1 ........................................................................... 1
Updated Outline Dimensions ....................................................... 13
Added Ordering Guide .................................................................. 14
Rev. E | Page 2 of 16
AD590
SPECIFICATIONS
AD590J AND AD590K SPECIFICATIONS
25°C and VS = 5 V, unless otherwise noted.1
Table 1.
Parameter
POWER SUPPLY
Operating Voltage Range
OUTPUT
Nominal Current Output @ 25°C (298.2K)
Nominal Temperature Coefficient
Calibration Error @ 25°C
Absolute Error (Over Rated Performance Temperature Range)
Without External Calibration Adjustment
With 25°C Calibration Error Set to Zero
Nonlinearity
For TO-52 and FLATPACK Packages
For 8-Lead SOIC Package
Repeatability2
Long-Term Drift3
Current Noise
Power Supply Rejection
4 V ≤ VS ≤ 5 V
5 V ≤ VS ≤ 15 V
15 V ≤ VS ≤ 30 V
Case Isolation to Either Lead
Effective Shunt Capacitance
Electrical Turn-On Time
Reverse Bias Leakage Current (Reverse Voltage = 10 V)4
Min
AD590J
Typ
Max
30
4
1
Min
AD590K
Typ
Max
Unit
30
V
±5.0
±2.5
μA
μA/K
°C
±10
±3.0
±5.5
±2.0
°C
°C
±1.5
±1.5
±0.1
±0.1
±0.8
±1.0
±0.1
±0.1
298.2
1
4
298.2
1
40
40
°C
°C
°C
°C
pA/√Hz
0.5
0.2
0.1
1010
100
20
10
0.5
0.2
0.1
1010
100
20
10
μA/V
μV/V
μA/V
Ω
pF
μs
pA
Specifications shown in boldface are tested on all production units at final electrical test. Results from those tests are used to calculate outgoing quality levels. All
minimum and maximum specifications are guaranteed, although only those shown in boldface are tested on all production units.
2
Maximum deviation between +25°C readings after temperature cycling between −55°C and +150°C; guaranteed, not tested.
3
Conditions: constant 5 V, constant 125°C; guaranteed, not tested.
4
Leakage current doubles every 10°C.
Rev. E | Page 3 of 16
AD590
AD590L AND AD590M SPECIFICATIONS
25°C and VS = 5 V, unless otherwise noted.1
Table 2.
Parameter
POWER SUPPLY
Operating Voltage Range
OUTPUT
Nominal Current Output @ 25°C (298.2K)
Nominal Temperature Coefficient
Calibration Error @ 25°C
Absolute Error (Over Rated Performance Temperature Range)
Without External Calibration Adjustment
With ± 25°C Calibration Error Set to Zero
Nonlinearity
Repeatability2
Long-Term Drift3
Current Noise
Power Supply Rejection
4 V ≤ VS ≤ 5 V
5 V ≤ VS ≤ 15 V
15 V ≤ VS ≤ 30 V
Case Isolation to Either Lead
Effective Shunt Capacitance
Electrical Turn-On Time
Reverse Bias Leakage Current (Reverse Voltage = 10 V)4
Min
AD590L
Typ
Max
Min
30
4
AD590M
Typ
Max
30
4
298.2
1
298.2
1
Unit
V
40
40
μA
μA/K
°C
°C
°C
°C
°C
°C
°C
pA/√Hz
0.5
0.2
0.1
1010
100
20
10
0.5
0.2
0.1
1010
100
20
10
μA/V
μA/V
μA/V
Ω
pF
μs
pA
±1.0
±0.5
±3.0
±1.6
±0.4
±0.1
±0.1
±1.7
±1.0
±0.3
±0.1
±0.1
1
Specifications shown in boldface are tested on all production units at final electrical test. Results from those tests are used to calculate outgoing quality levels. All
minimum and maximum specifications are guaranteed, although only those shown in boldface are tested on all production units.
Maximum deviation between +25°C readings after temperature cycling between −55°C and +150°C; guaranteed, not tested.
3
Conditions: constant 5 V, constant 125°C; guaranteed, not tested.
4
Leakage current doubles every 10°C.
°K
+223°
°C
–50°
°F –100°
+273° +298° +323°
0°
+25°
0°
+32°
o
o
C=
+50°
+100°
+70°
+373°
+423°
+100°
+150°
+200°
+212°
5 o
( F − 32) K = oC + 273.15
9
9
F = ⎛⎜ oC + 32 ⎞⎟ oR = o F + 459.7
⎝5
⎠
Figure 4. Temperature Scale Conversion Equations
Rev. E | Page 4 of 16
+300°
00533-002
2
AD590
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter
Forward Voltage ( E+ or E−)
Reverse Voltage (E+ to E−)
Breakdown Voltage (Case E+ or E−)
Rated Performance Temperature Range 1
Storage Temperature Range1
Lead Temperature (Soldering, 10 sec)
1
Rating
44 V
−20 V
±200 V
−55°C to +150°C
−65°C to +155°C
300°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only and functional operation of the device at these or
any other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
The AD590 was used at −100°C and +200°C for short periods of
measurement with no physical damage to the device. However, the absolute
errors specified apply to only the rated performance temperature range.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
Rev. E | Page 5 of 16
AD590
PRODUCT DESCRIPTION
The AD590 is a 2-terminal temperature-to-voltage transducer. It
is available in a variety of accuracy grades and packages. When
using the AD590 in die form, the chip substrate must be kept
electrically isolated (floating) for correct circuit operation.
Figure 7 shows the typical V–I characteristic of the circuit at
25°C and the temperature extremes.
+
66MILS
Q2
Q1
R1
260Ω
R2
1040Ω
Q5
Q3
V+
Q4
C1
26pF
Q6
Q12
Q7
Q8
42MILS
V–
Q9
8
R4
11kΩ
Q10
R5
146Ω
R6
820Ω
00533-003
THE AD590 IS AVAILABLE IN LASER-TRIMMED CHIP FORM;
CONSULT THE CHIP CATALOG FOR DETAILS
R3
5kΩ
Q11
1
1
00533-004
CHIP
SUBSTRATE
–
Figure 6. Schematic Diagram
Figure 5. Metallization Diagram
The AD590 uses a fundamental property of the silicon
transistors from which it is made to realize its temperature
proportional characteristic: if two identical transistors are
operated at a constant ratio of collector current densities, r,
then the difference in their base-emitter voltage is (kT/q)(In r).
Because both k (Boltzman’s constant) and q (the charge of an
electron) are constant, the resulting voltage is directly
proportional to absolute temperature (PTAT). 1
+150°C
IOUT (µA)
423
–55°C
218
00533-005
In the AD590, this PTAT voltage is converted to a PTAT current
by low temperature coefficient thin-film resistors. The total
current of the device is then forced to be a multiple of this
PTAT current. Figure 6 is the schematic diagram of the AD590.
In this figure, Q8 and Q11 are the transistors that produce the
PTAT voltage. R5 and R6 convert the voltage to current. Q10,
whose collector current tracks the collector currents in Q9 and
Q11, supplies all the bias and substrate leakage current for the
rest of the circuit, forcing the total current to be PTAT. R5 and
R6 are laser-trimmed on the wafer to calibrate the device at 25°C.
+25°C
298
0
1
2
3
4
5
SUPPLY VOLTAGE (V)
6
30
Figure 7. V–I Plot
1
For a more detailed description, see M.P. Timko, “A Two-Terminal IC
Temperature Transducer,” IEEE J. Solid State Circuits, Vol. SC-11, p. 784-788,
Dec. 1976. Understanding the Specifications–AD590.
Rev. E | Page 6 of 16
AD590
5V +
EXPLANATION OF TEMPERATURE SENSOR
SPECIFICATIONS
+
AD590
The way in which the AD590 is specified makes it easy to apply
it in a wide variety of applications. It is important to understand
the meaning of the various specifications and the effects of the
supply voltage and thermal environment on accuracy.
R
100Ω
+
VT = 1mV/K
950Ω
–
–
00533-007
–
Figure 9. One Temperature Trim
At final factory test, the difference between the indicated
temperature and the actual temperature is called the calibration
error. Since this is a scale factory error, its contribution to the
total error of the device is PTAT. For example, the effect of the
1°C specified maximum error of the AD590L varies from 0.73°C
at −55°C to 1.42°C at 150°C. Figure 8 shows how an exaggerated
calibration error would vary from the ideal over temperature.
Each AD590 is tested for error over the temperature range with
the calibration error trimmed out. This specification could also
be called the variance from PTAT, because it is the maximum
difference between the actual current over temperature and a
PTAT multiplication of the actual current at 25°C. This error
consists of a slope error and some curvature, mostly at the
temperature extremes. Figure 10 shows a typical AD590K
temperature curve before and after calibration error trimming.
2
IOUT (µA)
ACTUAL
TRANSFER
FUNCTION
IACTUAL
CALIBRATION
ERROR
298.2
IDEAL
TRANSFER
FUNCTION
BEFORE
CALIBRATION
TRIM
CALIBRATION
ERROR
0
AFTER
CALIBRATION
TRIM
–2
00533-008
CALIBRATION ERROR
ERROR VS. TEMPERATURE: CALIBRATION ERROR
TRIMMED OUT
ABSOLUTE ERROR (°C)
The AD590 is a PTAT 1 current regulator. That is, the output
current is equal to a scale factor times the temperature of the
sensor in degrees Kelvin. This scale factor is trimmed to 1 μA/K
at the factory, by adjusting the indicated temperature (that is,
the output current) to agree with the actual temperature. This is
done with 5 V across the device at a temperature within a few
degrees of 25°C (298.2K). The device is then packaged and
tested for accuracy over temperature.
–55
150
TEMPERATURE (°C)
00533-006
Figure 10. Effect to Scale Factor Trim on Accuracy
298.2
TEMPERATURE (°K)
Figure 8. Calibration Error vs. Temperature
The calibration error is a primary contributor to the maximum
total error in all AD590 grades. However, because it is a scale
factor error, it is particularly easy to trim. Figure 9 shows the
most elementary way of accomplishing this. To trim this circuit,
the temperature of the AD590 is measured by a reference
temperature sensor and R is trimmed so that VT = 1 mV/K at
that temperature. Note that when this error is trimmed out at
one temperature, its effect is zero over the entire temperature
range. In most applications, there is a current-to-voltage
conversion resistor (or, as with a current input ADC, a
reference) that can be trimmed for scale factor adjustment.
ERROR VS. TEMPERATURE: NO USER TRIMS
Using the AD590 by simply measuring the current, the total
error is the variance from PTAT, described above, plus the effect
of the calibration error over temperature. For example, the
AD590L maximum total error varies from 2.33°C at −55°C to
3.02°C at 150°C. For simplicity, only the large figure is shown
on the specification page.
NONLINEARITY
Nonlinearity as it applies to the AD590 is the maximum
deviation of current over temperature from a best-fit straight
line. The nonlinearity of the AD590 over the −55°C to +150°C
range is superior to all conventional electrical temperature
sensors such as thermocouples, RTDs, and thermistors. Figure 11
shows the nonlinearity of the typical AD590K from Figure 10.
1
T(°C) = T(K) − 273.2. Zero on the Kelvin scale is absolute zero; there is no
lower temperature.
Rev. E | Page 7 of 16
AD590
VOLTAGE AND THERMAL ENVIRONMENT EFFECTS
The power supply rejection specifications show the maximum
expected change in output current vs. input voltage changes.
The insensitivity of the output to input voltage allows the use of
unregulated supplies. It also means that hundreds of ohms of
resistance (such as a CMOS multiplexer) can be tolerated in
series with the device.
0.8
0.8°C MAX
0
0.8°C
MAX
0.8°C
MAX
It is important to note that using a supply voltage other than 5 V
does not change the PTAT nature of the AD590. In other words,
this change is equivalent to a calibration error and can be
removed by the scale factor trim (see Figure 10).
00533-009
–0.8
–1.6
–55
150
TEMPERATURE (°C)
Figure 11. Nonlinearity
Figure 12 shows a circuit in which the nonlinearity is the major
contributor to error over temperature. The circuit is trimmed
by adjusting R1 for a 0 V output with the AD590 at 0°C. R2 is
then adjusted for 10 V output with the sensor at 100°C. Other
pairs of temperatures can be used with this procedure as long as
they are measured accurately by a reference sensor. Note that
for 15 V output (150°C), the V+ of the op amp must be greater
than 17 V. Also, note that V− should be at least −4 V; if V− is
ground, there is no voltage applied across the device.
The AD590 specifications are guaranteed for use in a low
thermal resistance environment with 5 V across the sensor.
Large changes in the thermal resistance of the sensor’s environment
change the amount of self-heating and result in changes in the
output, which are predictable but not necessarily desirable.
The thermal environment in which the AD590 is used
determines two important characteristics: the effect of selfheating and the response of the sensor with time. Figure 14 is a
model of the AD590 that demonstrates these characteristics.
TJ
TC
θCA
+
15V
P
35.7kΩ
AD581
θJC
R1
2kΩ
97.6kΩ
CCH
R2
5kΩ
CC
–
TA
00533-012
ABSOLUTE ERROR (°C)
1.6
Figure 14. Thermal Circuit Model
30pF
27kΩ
As an example, for the TO-52 package, θJC is the thermal
resistance between the chip and the case, about 26°C/W. θCA is
the thermal resistance between the case and the surroundings
and is determined by the characteristics of the thermal
connection. Power source P represents the power dissipated
on the chip. The rise of the junction temperature, TJ, above the
ambient temperature, TA, is
100mV/°C
VT = 100mV/°C
AD707A
00533-010
AD590
V–
Figure 12. 2-Temperature Trim
TJ − TA = P(θJC + θCA)
0
–2
00533-011
TEMPERATURE (°C)
2
–55
0
100
TEMPERATURE (°C)
150
(1)
Table 4 gives the sum of θJC and θCA for several common
thermal media for both the H and F packages. The heat sink
used was a common clip-on. Using Equation 1, the temperature
rise of an AD590 H package in a stirred bath at 25°C, when
driven with a 5 V supply, is 0.06°C. However, for the same
conditions in still air, the temperature rise is 0.72°C. For a given
supply voltage, the temperature rise varies with the current and
is PTAT. Therefore, if an application circuit is trimmed with the
sensor in the same thermal environment in which it is used, the
scale factor trim compensates for this effect over the entire
temperature range.
Figure 13. Typical 2-Trim Accuracy
Rev. E | Page 8 of 16
AD590
Table 4. Thermal Resistance
45
115
–
190
5.0
13.5
–
10.0
191
480
–
650
108
60
–
30
TFINAL
T(t) = TINITIAL + (TFINAL – TINITIAL) × (1 – e–t/τ)
00533-013
τ (sec)1
H
F
0.6
0.1
1.4
0.6
SENSED TEMPERATURE
Medium
Aluminum Block
Stirred Oil2
Moving Air3
With Heat Sink
Without Heat Sink
Still Air
With Heat Sink
Without Heat Sink
θJC + θCA
(°C/Watt)
H
F
30
10
42
60
1
τ is dependent upon velocity of oil; average of several velocities listed above.
Air velocity @ 9 ft/sec.
3
The time constant is defined as the time required to reach 63.2% of an
instantaneous temperature change.
2
The time response of the AD590 to a step change in
temperature is determined by the thermal resistances and the
thermal capacities of the chip, CCH, and the case, CC. CCH is
about 0.04 Ws/°C for the AD590. CC varies with the measured
medium, because it includes anything that is in direct thermal
contact with the case. The single time constant exponential
curve of Figure 15 is usually sufficient to describe the time
response, T (t). Table 4 shows the effective time constant, τ, for
several media.
Rev. E | Page 9 of 16
TINITIAL
τ
4τ
TIME
Figure 15. Time Response Curve
AD590
GENERAL APPLICATIONS
V+
Figure 16 demonstrates the use of a low cost digital panel meter
for the display of temperature on either the Kelvin, Celsius, or
Fahrenheit scales. For Kelvin temperature, Pin 9, Pin 4, and
Pin 2 are grounded; for Fahrenheit temperature, Pin 4 and Pin 2
are left open.
R3
10kΩ
+
AD590L
#2
–
–
+
8
9
OFFSET
CALIBRATION
AD2040
4
GAIN
SCALING
6
AD590
–
5
GND
Figure 16. Variable Scale Display
The above configuration yields a 3-digit display with 1°C or 1°F
resolution, in addition to an absolute accuracy of ±2.0°C over
the −55°C to +125°C temperature range, if a one-temperature
calibration is performed on an AD590K, AD590L, or AD590M.
Connecting several AD590 units in series, as shown in Figure 17,
allows the minimum of all the sensed temperatures to be
indicated. In contrast, using the sensors in parallel yields the
average of the sensed temperatures.
Figure 19 is an example of a cold junction compensation circuit
for a Type J thermocouple using the AD590 to monitor the
reference junction temperature. This circuit replaces an ice-bath
as the thermocouple reference for ambient temperatures
between 15°C and 35°C. The circuit is calibrated by adjusting RT
for a proper meter reading with the measuring junction at a
known reference temperature and the circuit near 25°C. Using
components with the TCs as specified in Figure 19, compensation
accuracy is within ±0.5°C for circuit temperatures between
15°C and 35°C. Other thermocouple types can be accommodated
with different resistor values. Note that the TCs of the voltage
reference and the resistors are the primary contributors to error.
7.5V
15V
+
5V
–
+
+
+
+
+
–
+
–
–
–
–
AD590
+
AD590
–
+ AD580
333.3Ω
(0.1%)
+
VT AVG
–
–
00533-015
+
VT MIN
CONSTANTAN
AD590
AD590
–
IRON
REFERENCE
JUNCTION
52.3Ω
VOUT
8.66kΩ
RT
1kΩ
Figure 17. Series and Parallel Connection
The circuit in Figure 18 demonstrates one method by which
differential temperature measurements can be made. R1 and R2
can be used to trim the output of the op amp to indicate a
desired temperature difference. For example, the inherent offset
between the two devices can be trimmed in. If V+ and V− are
radically different, then the difference in internal dissipation
causes a differential internal temperature rise. This effect can be
used to measure the ambient thermal resistance seen by the
sensors in applications such as fluid-level detectors or anemometry.
–
CU
+
–
MEASURING
JUNCTION
METER
RESISTORS ARE 1%, 50ppm/°C
00533-017
AD590
10kΩ
(0.1%)
(T1 – T2) × (10mV/°C)
+
R4
10kΩ
V–
OFFSET
SCALING
2
3
R2
50kΩ
Figure 18. Differential Measurements
00533-014
+
AD707A
R1
5MΩ
00533-016
AD590L
#1
–
5V
Figure 19. Cold Junction Compensation Circuit for Type J Thermocouple
Rev. E | Page 10 of 16
AD590
20pF
Figure 20 is an example of a current transmitter designed to be
used with 40 V, 1 kΩ systems; it uses its full current range of 4
to 20 mA for a narrow span of measured temperatures. In this
example, the 1 μA/K output of the AD590 is amplified to
1 mA/°C and offset so that 4 mA is equivalent to 17°C and
20 mA is equivalent to 33°C. RT is trimmed for proper reading
at an intermediate reference temperature. With a suitable choice
of resistors, any temperature range within the operating limits
of the AD590 can be chosen.
1.25kΩ
AD581
–
VOUT
AD590
30pF
BIT 2
BIT 7
200Ω, 15T
+5V
BIT 3
BIT 6
+2.5V
BIT 4
BIT 5
+
–
AD590
–
AD707A
–
+
12.7kΩ
+5V
10kΩ
AD580
200Ω
+5V
1kΩ
3
8
LM311
2
1
4
–15V
5kΩ
7
OUTPUT HIGHTEMPERATURE ABOVE SETPOINT
OUTPUT LOWTEMPERATURE BELOW SETPOINT
5.1MΩ
–15V
500Ω
6.8kΩ
10Ω
Figure 22. DAC Setpoint
00533-018
0.01µF
BIT 8
1kΩ, 15T
RT
5kΩ
+
1.15kΩ
BIT 1
6.98kΩ
35.7kΩ
+5V
00533-020
+
MC
1408/1508
DAC OUT
V+
4mA = 17°C
12mA = 25°C
20mA = 33°C
REF
–15V
V–
Figure 20. 4 to 20 mA Current Transmitter
Figure 21 is an example of a variable temperature control circuit
(thermostat) using the AD590. RH and RL are selected to set the
high and low limits for RSET. RSET could be a simple pot, a
calibrated multiturn pot, or a switched resistive divider. Powering
the AD590 from the 10 V reference isolates the AD590 from
supply variations while maintaining a reasonable voltage (~7 V)
across it. Capacitor C1 is often needed to filter extraneous noise
from remote sensors. RB is determined by the β of the power
transistor and the current requirements of the load.
The voltage compliance and the reverse blocking characteristic
of the AD590 allow it to be powered directly from 5 V CMOS
logic. This permits easy multiplexing, switching, or pulsing for
minimum internal heat dissipation. In Figure 23, any AD590
connected to a logic high passes a signal current through the
current measuring circuitry, while those connected to a logic
zero pass insignificant current. The outputs used to drive the
AD590s can be employed for other purposes, but the additional
capacitance due to the AD590 should be taken into account.
5V
V+
V+
AD581
OUT
+
10V
V–
RH
AD590
+
–
RSET
RB
2
HEATING
ELEMENTS
+
+
1
–
AD590
–
–
–
4
1kΩ (0.1%)
GND
00533-021
10kΩ
00533-019
3 +
C1
+
7
–
LM311
RL
CMOS
GATES
Figure 21. Simple Temperature Control Circuit
Figure 23. AD590 Driven from CMOS Logic
Figure 22 shows that the AD590 can be configured with an 8-bit
DAC to produce a digitally controlled setpoint. This particular
circuit operates from 0°C (all inputs high) to 51.0°C (all inputs
low) in 0.2°C steps. The comparator is shown with 1.0°C
hysteresis, which is usually necessary to guard-band for extraneous
noise. Omitting the 5.1 MΩ resistor results in no hysteresis.
Rev. E | Page 11 of 16
AD590
CMOS analog multiplexers can also be used to switch AD590
current. Due to the AD590’s current mode, the resistance of
such switches is unimportant as long as 4 V is maintained
across the transducer. Figure 24 shows a circuit that combines
the principle demonstrated in Figure 23 with an 8-channel
CMOS multiplexer. The resulting circuit can select 1 to 80
sensors over only 18 wires with a 7-bit binary word.
The inhibit input on the multiplexer turns all sensors off for
minimum dissipation while idling.
Figure 25 demonstrates a method of multiplexing the AD590 in
the 2-trim mode (see Figure 12 and Figure 13). Additional AD590s
and their associated resistors can be added to multiplex up to
eight channels of ±0.5°C absolute accuracy over the temperature
range of −55°C to +125°C. The high temperature restriction of
125°C is due to the output range of the op amps; output to 150°C
can be achieved by using a 20 V supply for the op amp.
10V
16
4028
CMOS
BCD-TODECIMAL
11 DECODER
12
13
10
8
ROW
SELECT
0
1
2
3
14
2
+
+
+
+
–
–
22
02 +
–
12
16
9
10
11
6
INHIBIT
+
–
11
01 +
2
1
0
15
14
13
–
21
–
10V
COLUMN
SELECT
+
+
–
–
20
LOGIC
LEVEL
INTERFACE
–
10
AD590
00
4051 CMOS ANALOG
MULTIPLEXER
BINARY TO 1-OF-8 DECODER
7
8
00533-022
10kΩ 10mV/°C
Figure 24. Matrix Multiplexer
+15V
35.7kΩ
+
35.7kΩ
–
5kΩ
2kΩ
5kΩ
97.6kΩ
97.6kΩ
VOUT
V+
S1
AD707A
S2
DECODER/
DRIVER
27kΩ
10mV/°C
–15V
S8
+15V
AD7501
–15V
AD590L
+
+
–
–
TTL/DTL TO CMOS
INTERFACE
EN
AD590L
BINARY
CHANNEL
SELECT
–5V TO –15V
Figure 25. 8-Channel Multiplexer
Rev. E | Page 12 of 16
00533-023
AD581
2kΩ
AD590
OUTLINE DIMENSIONS
0.030 (0.76)
TYP
POSITIVE LEAD
INDICATOR
0.019 (0.48)
0.017 (0.43)
0.015 (0.38)
0.093 (2.36)
0.081 (2.06)
0.055 (1.40)
0.050 (1.27)
0.045 (1.14)
0.500 (12.69)
MIN
0.240 (6.10)
0.230 (5.84)
0.220 (5.59)
0.0065 (0.17)
0.0050 (0.13)
0.0045 (0.12)
0.210 (5.34)
0.200 (5.08)
0.190 (4.83)
0.050 (1.27)
0.041 (1.04)
0.015 (0.38)
TYP
Figure 26. 2-Lead Ceramic Flat Package [FLATPACK]
(F-2)
Dimensions shown in inches and (millimeters)
0.150 (3.81)
0.115 (2.92)
0.500 (12.70)
MIN
0.250 (6.35) MIN
0.050 (1.27) T.P.
0.100
(2.54)
T.P.
0.019 (0.48)
0.016 (0.41)
0.030 (0.76) MAX
0.048 (1.22)
0.028 (0.71)
3
0.195 (4.95)
0.178 (4.52)
0.021 (0.53) MAX
2
0.050
(1.27)
T.P.
0.046 (1.17)
0.036 (0.91)
1
45° T.P.
BASE & SEATING PLANE
CONTROLLING DIMENSIONS ARE IN INCHES; MILLIMETER DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF INCH EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN.
Figure 27. 3-Pin Metal Header Package [TO-52]
(H-03-1)
Dimensions shown in inches and (millimeters)
Rev. E | Page 13 of 16
022306-A
0.230 (5.84)
0.209 (5.31)
0.050 (1.27) MAX
AD590
5.00 (0.1968)
4.80 (0.1890)
8
1
5
4
1.27 (0.0500)
BSC
0.25 (0.0098)
0.10 (0.0040)
COPLANARITY
0.10
SEATING
PLANE
6.20 (0.2441)
5.80 (0.2284)
1.75 (0.0688)
1.35 (0.0532)
0.51 (0.0201)
0.31 (0.0122)
0.50 (0.0196)
0.25 (0.0099)
45°
8°
0°
0.25 (0.0098)
0.17 (0.0067)
1.27 (0.0500)
0.40 (0.0157)
COMPLIANT TO JEDEC STANDARDS MS-012-A A
CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN.
012407-A
4.00 (0.1574)
3.80 (0.1497)
Figure 28. 8-Lead Standard Small Outline Package [SOIC_N]
Narrow Body
(R-8)
Dimensions shown in millimeters and (inches)
ORDERING GUIDE
Model
AD590JF 1
AD590JH1
AD590JR
AD590JRZ 2
AD590JRZ-RL2
AD590KF1
AD590KH1
AD590KR
AD590KR-REEL
AD590KRZ2
AD590KRZ-RL2
AD590LF1
AD590LH1
AD590MF1
AD590MH1
AD590JCHIPS
1
2
Temperature Range
−55°C to +150°C
−55°C to +150°C
−55°C to +150°C
−55°C to +150°C
−55°C to +150°C
−55°C to +150°C
−55°C to +150°C
−55°C to +150°C
−55°C to +150°C
−55°C to +150°C
−55°C to +150°C
−55°C to +150°C
−55°C to +150°C
−55°C to +150°C
−55°C to +150°C
−55°C to +150°C
Package Description
2-Lead FLATPACK
3-Pin TO-52
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
2-Lead FLATPACK
3-Pin TO-52
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
2-Lead FLATPACK
3-Pin TO-52
2-Lead FLATPACK
3-Pin TO-52
3-Pin TO-52
Available in 883B; consult sales for data sheet.
Z = RoHS Compliant Part.
Rev. E | Page 14 of 16
Package Option
F-2
H-03-1
R-8
R-8
R-8
F-2
H-03-1
R-8
R-8
R-8
R-8
F-2
H-03-1
F-2
H-03-1
H-03-1
AD590
NOTES
Rev. E | Page 15 of 16
AD590
NOTES
©2006–2009 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D00533-0-9/09(E)
Rev. E | Page 16 of 16
Similar pages