Advantech ADAM-4168 Robust 8-ch thermocouple input module with modbus Datasheet

ADAM-4118
ADAM-4150
ADAM-4168
ADAM-4118
Robust 8-ch Thermocouple Input Module
with Modbus
Robust 15-ch Digital I/O Module with
Modbus
Robust 8-ch Relay Output Module with
Modbus
ADAM-4150
RoHS
COMPLIANT
2002/95/EC
Specifications
RoHS
COMPLIANT
2002/95/EC
Specifications
ADAM-4168
RoHS
COMPLIANT
2002/95/EC
Specifications
General
General
General
ƒƒ Power Consumption 0.5W @ 24 VDC
ƒƒ Power Consumption 0.7 W @ 24 VDC
ƒƒ Power Consumption 1.8 W @ 24 VDC
Analog Input
ƒƒ Channels
ƒƒ Input Impedance
ƒƒ Input Type
ƒƒ Input Range
Thermocouple
Digital Input
8 differential and
independent configuration
channels
Voltage: 20 MΩ
Current: 120 Ω
T/C, mV, V, mA
J
0 ~ 760°C
R
500 ~ 1,750°C
K
0 ~ 1,370°C
S
500 ~ 1,750°C
T
-100 ~ 400°C
B
500 ~ 1,800°C
E
0 ~ 1,000°C
Voltage mode
ƒƒ
ƒƒ
ƒƒ
ƒƒ
ƒƒ
ƒƒ
ƒƒ
ƒƒ
ƒƒ
ƒƒ
ƒƒ
±15 mV, ±50 mV,
±100 mV, ±500 mV,
±1 V, ±2.5 V
Current mode
±20 mA, 4 ~ 20 mA
Accuracy
Voltage mode: ±0.1% or
better
Current mode: ±0.2% or
better
Resolution
16-bit
Sampling Rate
10/100 samples/sec
(selected by Utility)
CMR @ 50/60 Hz
92 dB
NMR @ 50/60 Hz
60 dB
Overvoltage Protection
±60 VDC
High Common Mode 200 VDC
Span Drift
±25 ppm/°C
Zero Drift
±6μV/°C
Built-in TVS/ESD Protection
Burn-out Detection
ƒƒ Channels
ƒƒ Input Level
Dry contact:
ƒƒ
ƒƒ
ƒƒ
ƒƒ
Relay Output
ƒƒ Output Channels
ƒƒ Contact Rating
7
Logic level 0: Close to GND
Logic level 1: Open
Wet contact:
Logic level 0: 3 V max
Logic level 1: 10 ~ 30 V
(Note: The Digital Input Level 0 and 1 status can be
inverted)
Supports 3 kHz Counter Input (32-bit + 1-bit
overflow)
Supports 3 kHz Frequency Input
Supports Invert DI Status
Over Voltage Protection
40 VDC
Digital Output
ƒƒ Power Input
ƒƒ Watchdog Timer
ƒƒ
ƒƒ
ƒƒ
ƒƒ
ƒƒ
8, open collector to 40 V
(0.8A max. load)
Power Dissipation 1W load max
RON Maximum
150 mΩ
Supports 1 kHz Pulse Output
Supports High-to-Low Delay Output
Supports Low-to-High Delay Output
ƒƒ Connector
ƒƒ Isolation Voltage
Ordering Information
ƒƒ Supported Protocols
Unregulated 10 ~ 48 VDC
System (1.6 second) &
Communication
2 x plug-in terminal
blocks (#14 ~ 22 AWG)
3,000 VDC
ƒƒ Breakdown Voltage
ƒƒ Initial Insulation
Resistance
ƒƒ Relay Response
On: 3ms
Time (Typical)
Off: 1ms
ƒƒ Total Switching Time 10 ms
ƒƒ Supports 100 Hz pulse output
ƒƒ Maximum Operating 50 operations/min
Speed
(at related load)
ƒƒ Channels
Common Specifications
General
8 Form A
0.5 A @ 120 VAC (Resistive)
0.25 A @ 240 VAC
1 A @ 30 VDC
0.3 A @ 110 VDC
750 VAC (50/60 Hz)
1 G Ω min. @ 500 VDC
ASCII Command and
Modbus/RTU
Environment
ƒƒ Operating Humidity
5 ~ 95% RH
ƒƒ Operating Temperature -40 ~ 85°C
(-40 ~ 185°F)
ƒƒ Storage Temperature -40 ~ 85°C
(-40 ~ 185°F)
ƒƒ ADAM-4118
ƒƒ ADAM-4150
ƒƒ ADAM-4168
Robust 8-ch
Thermocouple Input
Module w/ Modbus
Robust 15-ch Digital I/O
Module with Modbus
Robust 8-ch Relay
Output Module with
Modbus
RS-485 I/O Modules: ADAM-4000
All product specifications are subject to change without notice
Last updated : 5-May-2015