AIMTEC AM2LV-NZ 2 watt | dc-dc converter Datasheet

Series AM2LV-NZ
2 Watt | DC-DC Converter
FEATURES:
•
•
•
•
SMD package
Wide (2:1) input range
1500VDC isolation
Continuous short circuit protection
•
•
•
•
Operating temperature: -40°C to +85°C
Regulated single/dual output
MTBF>1,000,000 hours
RoHS compliant
Models
Single output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
Efficiency
(%)
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
3.3
5
9
12
15
3.3
5
9
12
15
500
400
222
167
133
500
400
222
167
133
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
70
74
76
78
79
72
76
78
80
80
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
Efficiency
(%)
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
±5
±9
±12
±15
±5
±9
±12
±15
±200
±111
±83
±67
±200
±111
±83
±67
1500
1500
1500
1500
1500
1500
1500
1500
74
76
78
80
74
76
78
80
AM2LV-1203S-NZ
AM2LV-1205S-NZ
AM2LV-1209S-NZ
AM2LV-1212S-NZ
AM2LV-1215S-NZ
AM2LV-2403S-NZ
AM2LV-2405S-NZ
AM2LV-2409S-NZ
AM2LV-2412S-NZ
AM2LV-2415S-NZ
Models
Dual output
Model
AM2LV-1205D-NZ
AM2LV-1209D-NZ
AM2LV-1212D-NZ
AM2LV-1215D-NZ
AM2LV-2405D-NZ
AM2LV-2409D-NZ
AM2LV-2412D-NZ
AM2LV-2415D-NZ
NOTE: Unless otherwise specified, all specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input
voltage and at rated output load.
Input Specifications
Parameters
Voltage range
Absolute Maximum Rating
Nominal
Typical
12
24
12
24
9-18
18-36
Maximum
VDC
22
40
100
Peak Input Voltage time
Units
VDC
ms
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
www.aimtec.com
F 051e R8.C
Conditions
60 sec
At 500 Vdc
Input to Output
Typical
1000
85
Tel: +1 514 620 2722
1 of 4
Rated
Units
1500
VDC
MOhm
pF
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2LV-NZ
2 Watt | DC-DC Converter
Output Specifications
Parameters
Conditions
Voltage accuracy
Short Circuit protection
Short circuit restart
Line voltage regulation (Single)
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise *
Minimum Load Current**
Typical
Maximum
±5
Continuous
Auto-Recovery
±0.5
±1
From Low in to High In
From 10% to 100% load
From 10% to 100% load
Each output loaded within 5% of each other
20MHz Bandwidth with 10% load
Units
%
%
%
±5
%
±0.03
75
10
%/oC
mV p-p
% of Max
* Test Ripple & Noise by “Parallel Cable Method” as described in Application Note “Ripple and Noise Measurement of Brick & POL DC-DC Converters”
available on Aimtec’s website www.aimtec.com. Converters are designed to operate with a minimum load of 10%. If converter is operated with a load less
than 10% the ripple will increase.
** Operation under 10% load will not damage the converter; However, not all specifications will be met.
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum Soldering Temperature
Conditions
Typical
100% load
300
Maximum
KHz
o
C
o
C
o
C
%/ oC
-40 to +85
-55 to +125
Above 71º
Units
2.9
Free Air Convection
95
Plastic (UL94-V0)
5.2
0.94 x 0.54 x 0.32 inches 23.86 x 13.70 x 8.20 mm
>1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25ºC)
1.5mm from case for 10 seconds
245
% RH
g
o
C
Pin Out Specifications
Pin
1
7
8
9
10
16
Single
- Vin
NC
NC
+Vout
- Vout
+ Vin
Dual
- Vin
NC
Common
+Vout
-Vout
+ Vin
NC – not connected
www.aimtec.com
F 051e R8.C
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2LV-NZ
2 Watt | DC-DC Converter
Dimensions
Side View
Front View
23.86
(0.94)
15.00
(0.59)
7.50
(0.30)
A
A
8.20
(0.32)
0.50
(0.02)
0.50
(0.02)
5.00º angle
13.10
(0.52)
1.36
(0.05)MAX
17.50
(0.69)
Top View
1.02
(0.04)
23.86
(0.94)
16
0.80
(0.03)
0.50
(0.02)
10
Footprint
9
18.50
(0.73)
13.70
(0.54)
1
7
3.04
(0.12)
www.aimtec.com
F 051e R8.C
15.24
(0.60)
8
2.4
(0.08)
15.24
(0.60)
2.54
(0.10)
Tel: +1 514 620 2722
3 of 4
2.54
(0.10)
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2LV-NZ
2 Watt | DC-DC Converter
Recommended Filter Circuit
Single Output
Dual Output
+ Vin
Cout
Cin +
DC
DC
+
Cin +
Common
Cout
+Vout
+ Vin
+Vout
DC
DC
Cout
+
+
- Vout
-Vout
- Vin
- Vin
All the AM2LV-Z Series have been tested with the above recommended test circuit.
This series should be tested under load.
If it is necessary to further decrease the input/output ripple, the value of the filter capacitor can be increased; a capacitor with a low ESR
should be used. Excessive filter capacitance can cause start up problems with the converter.
In general, the recommended capacitance values are:
Cin: 12V input 100μF, 24V input 10μF~47μF
Cout: 10μF/100mA
Refer to table below for maximum capacitor values:
External Capacitor Value
Single Output
Vout (VDC)
3.3
5
9
12
15
Cout (uF)
2200
1000
680
470
330
Dual Output
Vout (VDC)
±5
±9
±12
±15
Cout (uF)
±680
±470
±330
±220
Derating
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R8.C
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only