AIMTEC AM1G0505SH30NZ 1 watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM1G-NZ
1 Watt | DC-DC Converter
FEATURES:








I/O Isolation of 1500 and 3000VDC
Very low no load consumption
Remote On/Off Control
8 pin SIP package
Operating temperature -40 to +100oC
Continuous Short circuit protection
Wide 2:1 input range
High efficiency up to 81%
Models
Single output
Model
Input
Voltage
(V)
Output
Voltage(V)
Output
Current max
(mA)
Isolation
(VDC)
Capacitor
Load
(μF)
Efficiency
(%)
AM1G-0503S-NZ
AM1G-0505S-NZ
AM1G-0512S-NZ
AM1G-0515S-NZ
AM1G-0524S-NZ
AM1G-1203S-NZ
AM1G-1205S-NZ
AM1G-1209S-NZ
AM1G-1212S-NZ
AM1G-1215S-NZ
AM1G-2403S-NZ
AM1G-2405S-NZ
AM1G-2412S-NZ
AM1G-2415S-NZ
AM1G-2424S-NZ
AM1G-4803S-NZ
AM1G-4805S-NZ
AM1G-4812S-NZ
AM1G-4815S-NZ
AM1G-0503SH30-NZ
AM1G-0505SH30-NZ
AM1G-0512SH30-NZ
AM1G-0515SH30-NZ
AM1G-1203SH30-NZ
AM1G-1205SH30-NZ
AM1G-1209SH30-NZ
AM1G-1212SH30-NZ
AM1G-1215SH30-NZ
AM1G-2403SH30-NZ
AM1G-2405SH30-NZ
AM1G-2412SH30-NZ
AM1G-2415SH30-NZ
AM1G-2424SH30-NZ
AM1G-4803SH30-NZ
AM1G-4805SH30-NZ
AM1G-4812SH30-NZ
AM1G-4815SH30-NZ
4.5-9
4.5-9
4.5-9
4.5-9
4.5-9
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
4.5-9
4.5-9
4.5-9
4.5-9
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
3.3
5
12
15
24
3.3
5
9
12
15
3.3
5
12
15
24
3.3
5
12
15
3.3
5
12
15
3.3
5
9
12
15
3.3
5
12
15
24
3.3
5
12
15
303
200
83
67
42
303
200
111
83
67
303
200
83
67
42
303
200
83
67
303
200
83
67
303
200
111
83
67
303
200
83
67
42
303
200
83
67
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
2700
2200
1000
680
470
2700
2200
1800
1000
680
2700
2200
1000
680
470
2700
2200
1000
680
2700
2200
1000
680
2700
2200
1800
1000
680
2700
2200
1000
680
470
2700
2200
1000
680
72
72
76
75
74
75
77
79
80
80
75
77
81
79
77
75
76
81
80
72
72
76
75
75
77
79
80
80
75
77
81
79
77
75
76
81
80
www.aimtec.com
F 051e R8
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1G-NZ
1 Watt | DC-DC Converter
Models
Dual output
Model
Input
Voltage (V)
Output
Voltage(V)
Output
Current max
(mA)
Isolation
(VDC)
Capacitor Load
(μF)
Efficiency
(%)
AM1G-0505D-NZ
AM1G-0512D-NZ
AM1G-0515D-NZ
AM1G-1205D-NZ
AM1G-1212D-NZ
AM1G-1215D-NZ
AM1G-2405D-NZ
AM1G-2409D-NZ
AM1G-2412D-NZ
AM1G-2415D-NZ
AM1G-4805D-NZ
AM1G-4812D-NZ
AM1G-4815D-NZ
AM1G-0505DH30-NZ
AM1G-0512DH30-NZ
AM1G-0515DH30-NZ
AM1G-1205DH30-NZ
AM1G-1212DH30-NZ
AM1G-1215DH30-NZ
AM1G-2405DH30-NZ
AM1G-2412DH30-NZ
AM1G-2415DH30-NZ
AM1G-4805DH30-NZ
AM1G-4812DH30-NZ
AM1G-4815DH30-NZ
4.5-9
4.5-9
4.5-9
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-75
36-75
36-75
4.5-9
4.5-9
4.5-9
9-18
9-18
9-18
18-36
18-36
18-36
36-75
36-75
36-75
±5
±12
±15
±5
±12
±15
±5
±9
±12
±15
±5
±12
±15
±5
±12
±15
±5
±12
±15
±5
±12
±15
±5
±12
±15
±100
±42
±33
±100
±42
±33
±100
±56
±42
±33
±100
±42
±33
±100
±42
±33
±100
±42
±33
±100
±42
±33
±100
±42
±33
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
±1000
±470
±330
±1000
±470
±330
±1000
±680
±470
±330
±1000
±470
±330
±1000
±470
±330
±1000
±470
±330
±1000
±470
±330
±1000
±470
±330
73
76
75
78
81
80
80
80
80
80
76
80
80
73
76
75
78
81
80
80
80
80
76
80
80
Input Specifications
Parameters
Voltage range
Nominal
Typical
5
12
24
48
4.5-9
9-18
18-36
36-75
Peak Input Voltage time
Filter
Maximum
Units
VDC
1
sec
Capacitor
5 Vin
12 Vin
24 Vin
48 Vin
5 Vin
12 Vin
24 Vin
48 Vin
5 Vin
12 Vin
24 Vin
48 Vin
Maximum Rating
No load input current
Input Reflected Ripple Current
On/Off Control*
12
25
50
100
25
12
6
4
30
40
55
70
ON – open or Isolated; OFF – high voltage level (current 5-10mA)
VDC
mA
mA
*Note: Exceeding 20mA of control current will permanently damage the converter.
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
www.aimtec.com
F 051e R8
Conditions
Typical
60sec, <1mA
> 1000
30
120
3000VDC Isolation,100kHz, 0.1V
1500VDC Isolation,100kHz, 0.1V
Tel: +1 514 620 2722
2 of 5
Rated
Units
1500, 3000
VDC
MOhm
pF
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1G-NZ
1 Watt | DC-DC Converter
Output Specifications
Parameters
Voltage accuracy
No Load Voltage accuracy
Voltage balance
Short Circuit Protection
Short Circuit Restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Transient Recovery Time
Transient Response Deviation
Ripple
Noise
Conditions
Typical
5 to 100% load
±2
±5
±0.5
Continuous
Automatic restart
±0.5
±0.6
±0.02
2
±5
50
90
Dual Output balanced load
LL~HL
load 5~100%
25% load step
25% load step
At 20MHz Bandwidth
At 20MHz Bandwidth
Maximum
Units
%
%
%
%
%/oC
msec
%
mV p-p
mV p-p
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
100% load
200
KHz
oC
Operating temperature
With derating above 85oC
-40 to +100
oC
Storage temperature
-55 to +125
oC
Case Temperature
105
oC
Lead Temperature
1.5mm from case for 10 Seconds
300
Cooling
Free air convection
Humidity
95
%
Case material
Plastic (UL94V-0 rated)
Weight
4.9
g
Dimensions (L x Wx H)
0.87 x 0.37 x 0.47 inch, 22 x 9.5 x 12 mm
MTBF
>1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Pin Out Specifications
Dimensions
Pin
Single
Dual
1
2
3
5
6
7
8
- V Input
+ V Input
On/Off Control
N.C.
+ V Output
- V Output
CS
- V Input
+ V Input
On/Off Control
N.C.
+ V Output
Common
- V Output
22.00
(0.87)
PRINTED
FACE
12.00
(0.47)
12.00
(0.47)
0.50
(0.02)
4.10
(0.16)
2.54
(0.10)
2.50
(0.98)
www.aimtec.com
F 051e R8
9.50
(0.37)
0.50
(0.02)
1
2
3
2.10
(0.08)
Tel: +1 514 620 2722
3 of 5
5
6
7
8
0.300
(0.012)
9.50
(0.37)
0.50
(0.02)
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1G-NZ
1 Watt | DC-DC Converter
Derating
Free Air Convection
85º C
Output Power (%)
100
80
Safe Operating Area
60
40
20
0
- 20
- 40
0
20
40
60
80
85
105
100
Ambient Temperature º C
Load
Recommended EMC Circuit
Model
C1
C2
C4
LDM
MOV
TVS
5 Vin
4.7µF / 50V
4.7µF / 50V
1nF /3KV
12 µH
-
SMCJ13A
12 Vin
4.7µF / 50V
4.7µF / 50V
1nF /3KV
12 µH
-
SMCJ28A
24 Vin
4.7µF / 100V
4.7µF / 50V
1nF /3KV
12 µH
S14K35
SMCJ48A
48 Vin
4.7µF / 100V
4.7µF / 100V
1nF /3KV
12 µH
S14K60
SMCJ90A
C3
680µF /
16V
680µF /
25V
330µF /
50V
330µF /
100V
LDM2
56µH
56µH
Cd
47nF
/100V
47nF
/100V
47nF
/100V
47nF
/100V
D1
RB160M60/1A
RB160M60/1A
RB160M60/1A
RB160M60/1A
R1
See
Formula
See
Formula
See
Formula
See
Formula
Note: Fuse is user selectable
R1 = ((Vcd – Vd1 – 1.0) / Icntl)‐ 300
www.aimtec.com
F 051e R8
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1G-NZ
1 Watt | DC-DC Converter
Recommended Circuits
Single Output
+Vout
LDM
+ Vin
6
2
C1
C2
CNTL
Cout
3
D1 R1
C3
‐ Vin
DC
8
DC
1
Cs
7
‐ Vout
Dual Output
+ Vin
6
2
C1
+Vout
LDM1
LDM
C2
CNTL
3
D1 R1
C3
‐ Vin
DC
DC
Cout
GND
7
Cout
LDM1
1
8
‐ Vout
Model
5 Vin
12 Vin
24 Vin
48 Vin
C1
100µF
100µF
10µF
10µF
C2
47µF
47µF
1µF
1µF
LDM
4.7 - 12 µH
4.7 - 12 µH
4.7 - 12 µH
4.7 - 12 µH
C3
47µF / 100V
47µF / 100V
47µF / 100V
47µF / 100V
D1
RB160M-60/1A
RB160M-60/1A
RB160M-60/1A
RB160M-60/1A
R1
See Formula
See Formula
See Formula
See Formula
LDM1
2.2 - 10 µH
2.2 - 10 µH
2.2 – 10 µH
2.2 - 10 µH
CS
10 - 22µF
10 - 22µF
10 - 22µF
10 - 22µF
Cout
100µF
100µF
100µF
100µF
R1 = ((Vcd – Vd1 – 1.0) / Icntl)‐ 300
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R8
Tel: +1 514 620 2722
5 of 5