Specifications
Rated voltage
1.5 Vo-p
Operating voltage
Mean current
1.0 - 3.0 Vo-p
20 mA max.
Coil resistance
Coil impedance
Sound output
30 ±4.5 Ω
105 Ω
Min. 80 (Typical 88) dBA
Rated frequency
Operating temperature
Storage temperature
Dimensions
Weight
Material
Terminal
RoHS
2,048 Hz
-20 ~ +60° C
-30 ~ +70° C
ø16.0 x H14.0 mm
4.6 g
PPO (Black)
Pin type (Au Plating)
yes
Applying rated voltage, 2048 Hz
square wave, ½ duty
See impedance measurements graph
Distance at 10cm (A-weight free air).
Applying rated voltage of 2048 Hz, square
wave, ½ duty.
See attached drawing
See attached drawing
Frequency Response Curve
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Part No: CEM-1601
Date: 9/08/2006
Unit: mm
Description: magnetic buzzer
Page No: 2 of 5
Appearance Drawing
Tolerance: ±0.5
Measurement Method
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Date: 9/08/2006
Part No: CEM-1601
Unit: mm
Description: magnetic buzzer
Page No: 3 of 5
Mechanical Characteristics
Item
Solderability
Soldering Heat Resistance
Terminal Mechanical Strength
Vibration
Drop Test
Test Condition
Lead terminals are immersed in rosin for 5
seconds and then immersed in solder bath
of 270 ±5°C for 3 ±1 seconds.
Lead terminals are immersed up to 1.5 mm
from the buzzer’s body in solder bath of
260 ±5°C for 3 ±1 seconds.
Apply a force of 9.8 N (1.0 kg) to each terminal
in each axial direction.
The buzzer will be measured after applying
a vibration amplitude of 1.52 mm with 10 to
55 Hz band of vibration frequency to each of
the 3 perpendicular directions for 2 hours.
The part is to be dropped from a height of
75 cm onto a 40 mm thick wooden board 3
times in 3 axis (X, Y, Z) for a total of 9 drops.
Evaluation Standard
90% min. lead terminals should
be wet with solder.
(Except the edge of the terminal.)
Test Condition
The part will be subjected to +70°C for
96 hours.
The part will be subjected to -30°C for
96 hours
The part will be subjected to 10 cycles. One
cycle will consist of:
Evaluation Standard
No in interference in operation.
No damage or cutting off.
After the test, the part should
meet specifications without any
damage to the appearance and
the SPL should be within
±10 dBA of the initial
measurement.
Environment Test
Item
High temp. test
Low temp. test
Thermal shock
Temp./Humidity cycle
Phone: 800.275.4899
The part shall be subjected to 10 cycles. One
cycle will be 24 hours and consist of:
Fax: 503.612.2381
www.cui.com
After the test, the part should
meet specifications without any
damage to the appearance or
performance except SPL. After 4
hours at 25°C, the SPL should be
within ±10 dBA of the initial
measurement.
20050 SW 112th Ave.
Tualatin, OR 97062
Date: 9/08/2006
Part No: CEM-1601
Unit: mm
Description: magnetic buzzer
Page No: 4 of 5
Reliability Tests
Item
Operating (Life Test)
Test Condition
1. Continuous life test:
The part will be subjected to 72 hours at 45°C
with 1.5 V, 2048 Hz applied.
Evaluation Standard
2. Intermittent life test:
A duty cycle of 1 minute on, 1 minute off, a
minimum of 10,000 times at room temp.
(+25 ±10°C) with 1.5 V, 2048 Hz applied.
After the test, the part shall meet
specifications without any
damage to the appearance. After
4 hours at +25°C, the SPL
should be within ±10 dBA of the
initial SPL.
Test Conditions
Standard Test Condition
Judgement Test Condition
Phone: 800.275.4899
a) Tempurature: +5 ~ +35°C
a) Tempurature: +25±2°C
Fax: 503.612.2381
b) Humidity: 45 - 85%
b) Humidity: 60 - 70%
www.cui.com
c) Pressure: 860 - 1060 mbar