Keysight E7623A Uxm wireless test set Datasheet

Keysight E7515A
UXM Wireless Test Set
Data Sheet
02 | Keysight | E7515A UXM Wireless Test Set - Data Sheet
Make a Clear Call
The team looks to you: will a new chipset or UE pass the crucial tests? Clarity comes
from accumulated insights – insights enabled by the Keysight Technologies’s UXM
wireless test set. The UXM is a highly integrated signaling test set created for functional
and RF design validation in the 4G era and beyond. It provides the capabilities you need
to test the newest designs, delivering LTE-Advanced data rates up to 1 Gbps now and
handling more complex requirements later. When the team counts on you, count on the
UXM to help you assess design readiness with greater confidence and make a clear call.
Definitions and Conditions
The specifications in this document apply to single TRX instruments with serial number
MY5520xxxx/TH5520xxxx and dual TRX instruments with serial number MY5521xxxx/
TH5521xxxx.
The test set will meet its specifications when
–– The test set is within its calibration cycle
–– The test set has been stored at an ambient temperature within the allowed operating
range for at least two hours before being turned on; if it had previously been stored
at a temperature range inside the allowed storage range, but outside the allowed
operating range
–– The test set has been turned on for at least 30 minutes
Specification
Specifications describe the performance parameters covered by the product warranty
and are valid from 20 to 35 °C unless otherwise noted.
Typical
Typical describes additional product performance information that is not covered by the
product warranty. It is performance beyond specifications that 95 percent of the units
exhibit with a 95 percent confidence level. This data, shown in italics, does not include
measurement uncertainty, and is valid only at room temperature (23 °C).
Nominal
Nominal values indicate expected performance, or describe product performance that is
useful in the application of the product, but are not covered by the product warranty.
03 | Keysight | E7515A UXM Wireless Test Set - Data Sheet
Vector Signal Analyzer Performance
Frequency and time specification
Operating frequency range
E7515A-504
E7515A-506
300 MHz to 3.8 GHz
300 MHz to 6.0 GHz
Frequency setting resolution
100 kHz
Frequency accuracy
See Timebase specifications
VSWR all RF inputs
300 MHz to 2.0 GHz
>2.0 to 5.0 GHz
>5.0 to 6.0 GHz
1.4 nominal
1.5 nominal
1.8 nominal
Amplitude and range specifications
CW level accuracy
–60 to +30 dBm for Rx1, Rx2;
–53 to +30 dBm for TxRx1, TxRx2
300 MHz to 3.5 GHz
>3.5 to 6.0 GHz
–53 to +3.5 dBm
300 MHz to 3.5 GHz
>3.5 to 6 GHz
±0.45 dB typical
±0.45 dB typical
±1.0 dB
±1.1 dB
Level flatness
±0.3 dB typical over 100 MHz bandwidth
Noise floor
For combined Tx and Rx
For separate Tx and Rx
<140 dBm/Hz nominal
<150 dBm/Hz nominal
Maximum CW input level at connectors
TxRx1 and TxRx2
+33 dBm
04 | Keysight | E7515A UXM Wireless Test Set - Data Sheet
Vector Signal Generator Performance
Frequency and time specification
Operating frequency range
E7515A-504
E7515A-506
300 MHz to 3.8 GHz
300 MHz to 6.0 GHz
Frequency setting resolution
100 kHz
Frequency accuracy
See Timebase specifications
VSWR all RF inputs
300 MHz to 2.0 GHz
>2.0 to 5.0 GHz
>5.0 to 6.0 GHz
1.4 nominal
1.5 nominal
1.8 nominal
Amplitude and range specifications
CW output power range
TxRx1, TxRx2
Tx1, Tx2
–110 to –7 dBm nominal (–110 to –10 dBm for typical and warranted)
–110 to +5 dBm nominal (–110 to 0 dBm for typical and warranted)
CW output level accuracy
TxRx1, TxRx2 and Tx1, Tx2
300 MHz to 3.5 GHz
> 3.5 to 6.0 GHz
±1.0 dB, ±0.45 dB typical
±1.0 dB, ±0.45 dB typical
Output level setting resolution
0.1 dB
Output level settling time
±1.0 dB within 25 µs nominal
Output flatness
±0.3 dB typical over 100 MHz bandwidth
Harmonics
Attenuation of 2nd harmonic TxRx1, TxRx2
300 MHz to 4.0 GHz, power <–10 dBm
>4.0 to 6.0 GHz, power <–10 dBm
>30 dB nominal
>45 dB nominal
Attenuation of 2nd harmonic Tx1, Tx2
300 MHz to 4.0 GHz, power <0 dBm
>4.0 to 6.0 GHz, power <0 dBm
>30 dB nominal
>45 dB nominal
Attenuation of 3rd harmonic TxRx1, TxRx2
300 MHz to 3.0 GHz, power <–10 dBm
>3.0 to 6.0 GHz, power <–10 dBm
>40 dB nominal
>55 dB nominal
Attenuation of 3rd harmonic Tx1, Tx2
300 MHz to 3.0 GHz, power <0 dBm
>3.0 to 6.0 GHz, power <0 dBm
>40 dB nominal
>55 dB nominal
Attenuation of non-harmonics TxRx1, TxRx2
300 MHz to 6.0 GHz, –10 dBm, power >–40 dBm
>40 dB nominal
Attenuation of non-harmonics Tx1, Tx2
300 MHz to 6.0 GHz, –10 dBm, power >–40 dBm
>40 dB nominal
Phase noise
–90 dB at 10 kHz offset nominal
Maximum reverse power
TxRx1, TxRx2
Tx1, Tx2
<±33 dBm
<±30 dBm
05 | Keysight | E7515A UXM Wireless Test Set - Data Sheet
Instrument Specifications
Input power requirements
Voltage and frequency
100/120/220/240 VAC, 50/60 Hz, nominal
Power consumption (instrument with 2 TRXs)
1100 W max
Additional specifications
Dimensions (H x W x L)
Without feet and handles
With feet and handles
305 mm x 435 mm x 445 mm
321 mm x 435 mm x 504 mm
Weight
One TRX
Two TRXs
33 kg
36 kg
Operating temperature
5 to 45 °C, 30 g/m³ absolute humidity, 5 to 85% non-condensing relative humidity
Storage temperature
–40 to +65 °C, 50 g/m³ absolute humidity, 5 to 85% non-condensing relative humidity
Altitude
Up to 2000 m
Radiated leakage due to RF generator
< 2.5 µV induced in a resonant dipole antenna one inch from any surface except the
underside and rear panel set at RF generator output frequency and output level of
–40 dBm typical
EMC
Complies with European EMC Directive 2004/108/EC
–– IEC/EN 61326-1
–– CISPR Pub 11 Group 1, class A
–– AS/NZS CISPR 11
–– ICES/NMB-001
–– This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme a la norme NMB-001 du Canada.
–– South Korean Class A EMC declaration: This equipment is Class A suitable for professional use and is for use in electromagnetic environments outside of the home.
A급 기기 (업무용 방송통신기 자재)
이기기는 업무용(A급) 전자파 적합기기로서 판매자 또 는 사용자는 이
점을 주의하시기 바라며, 가정외의 지역에서 사용하는 것을 목적으로
합니다.
Mechanical resistance
EN60068-2-6, EN60068-2-27, EN60068-2-64
Safety
Complies with European Low Voltage Directive 2006/95/EC
–– IEC/EN 61010-1, 3rd edition
–– Canada: CAN/CSA C22.2 No. 61010-1012
–– USA: UL std no. 61010-1, 3rd Edition
–– Acoustic statement (European Machinery Directive 2002/42/EC, 1.7.4.2u)
Acoustic noise emission, LpA <70 dB, Operator position, Normal operation
mode, Per ISO 7779
RF connections
Tx1, Tx2
N-type female, 50 Ω nominal
TxRx1, TxRx2
N-type female, 50 Ω nominal
Other connectors and interfaces
Display/Manual user interface
USB ports
Front panel
Rear
LAN (local area network) ports
15.4 in (391 mm) active matrix, color, 1280 x 800 pixel resolution TFT-LCD flat panel
display with touch panel controls; single-touch capacitive touch-screen; HDMI port
2 USB 2.0 ports
2 USB 2.0 ports
One external, 1 Gbps, LAN port rear panel
One external, 1 Gbps, LAN port front panel
06 | Keysight | E7515A UXM Wireless Test Set - Data Sheet
Instrument Specifications (continued)
Digital data acquisition
General memory budgets and considerations
RCB available memory
Memory allocation for digital acquisition
512 MB
256 MB
Basic acquisitions
IQ data acquisition channels
Sample rates
Maximum sample storage
2 (one per BS Rx antenna)
30.72 MSa/s, 122.88 MSa/s
32 MSa per BS Rx antenna
Fixed size buffers per channel and allocation
Single or dual channel (RF Carrier)
Single or dual channel (RF Input)
30.72 MHz: 1092 ms
122.88 MHz: 273 ms
Maximum digitalized data size
128 MB per channel
Trigger control
Immediate, event-based Ethernet
Source selection
RF Input (1 & 2)
RF Carrier (1 & 2)
100 MHz bandwidth (122.88 MSa/s)
20 MHz bandwidth (30.72 MSa/s)
Channel emulation
Antenna configuration
1x1, 1x2, 2x2, 4x2
3GPP LTE Rel 8 for RF fading profiles
Bypass
EPA 5, custom Max Doppler frequency
EVA 5, 70, 200, custom Max Doppler frequency
ETU 70, 200, 300, custom Max Doppler frequency
HST
CQI
3GPP TD-SCDMA/HSPA RF fading profiles
Bypass
Multi-path case 1 to 3
PA3
PB3
VA 30, 120
HST
Moving
Birth death
3GPP W-CDMA/HSPA+ RF fading profiles
Bypass
Multi-path case 1 to 3
PA3
PB3
VA 30, 120
HST
Moving
Birth death
07 | Keysight | E7515A UXM Wireless Test Set - Data Sheet
Instrument Specifications (continued)
PA3
PB3
2
VA 30, 120
No channel
Channel 1
Channel 2
Channel 1 and 2
HST
–189 to –81 dBm/Hz
–179 to –71 dBm/Hz
Moving
–49.6 to 49.6 MHz
Birth Death
1.08, 2.7, 4.5, 9.0, 13.5, 18.0 MHz
Continuous wave generation
Independent channels
2
Antenna output
No channel
Channel 1
Channel 2
Channel 1 and 2
Digital frequency offset
–50 to 50 MHz
Time base
Standard frequency reference
Maximum frequency drift
Short term stability
Warm-up time
±0.7 ppm/year
±0.005 ppm
1 minute to be ±0.1 ppm at 25 ºC
External clock time reference
Connector type
SMA connector SYNC IN, rear panel
Frequency
Sine wave
Square wave (greater than 40% ON duty cycle)
Input voltage range
Impedance
10 MHz
10 MHz
0.4 to 2 Vpp
50 Ω nominal
Format alignment trigger
External connector
SMA Channel 0
Trigger duration configurable according format
LTE
Where sample resolution = (1/30.72) x 10-6
0 to 30719 samples
Trigger offset delay
In terms of 1/6 of the period of the sample
Trigger period configurable according format
LTE
1 to 10240 packets
Generic trigger
External connector
SMA Channel 1, 2, 3 (Input, Output)
Arm channel for receiving trigger
Only input channels
External trigger generation
Only output channels
Warranty and calibration
Standard warranty
Three years
Recommended calibration cycle
One year
08 | Keysight | E7515A UXM Wireless Test Set - Data Sheet
LTE Measurements
Modulation and channels
Signal structure
FDD and TDD (with appropriate licenses)
Signal bandwidth
1.4, 3, 5, 10, 15, 20 MHz
LTE signal generation
Error vector magnitude (EVM)
20 MHz LTE PDSCH signal with full allocation (100 RBs)
modulation = 64QAM; power = –20 dBm
300 MHz to 3.5 GHz
>3.5 to 6 GHz
<2% RMS nominal
<2.25% RMS nominal
LTE power measurements
Level range (BW 20 MHz, OFDM, 64QAM)
–45 to +30 dBm, RMS
LTE channel power accuracy
±0.65 dB nominal
LTE adjacent channel power
Dynamic range
E-UTRA
UTRA
>45 dB nominal
>45 dB nominal
Residual EVM (5, 10, 15, 20 MHz bandwidths)
<2% RMS typical at –20 dBm input power
GSM/GPRS/EGPRS Measurements
Modulation, bands, and frequency
Modulation types
GMSK and 8PSK
Bands
GSM450, GSM480, GSM750, PGSM, EGSM, RGSM, TGSM810, GSM850, DCS, PCS
Frequency range
0.45 to 2 GHz (within bands)
GSM/GPRS/EGPRS signal generation
Modulated output power range
TxRx1, TxRx2
–110 to –10 dBm
Tx1, Tx2
–110 to 0 dBm
Output level accuracy with GMSK or 8PSK
±0.55 dB, typical
GSM/GPRS/EGPRS measurements
Level range
–25 to +30 dBm
Transmit power accuracy
±0.5 dB, typical
TD-SCDMA/HSPA Measurements
Modulation, bands, and frequency
Modulation types
QPSK and 16QAM
Bands
a, b, c, d, e, f, 41
Frequency range
1.8 to 2.7 GHz (within bands)
TD-SCDMA/HSPA signal generation
Modulated output power range
TxRx1, TxRx2
–110 to –13 dBm/1.28 MHz
Tx1, Tx2
–110 to –5 dBm/1.28 MHz
Output level accuracy with QPSK or 16QAM
±0.5 dB, typical
TD-SCDMA/HSPA measurements
Level range
–65 to +30 dBm/1.28 MHz
Channel power accuracy
±0.5 dB, typical
09 | Keysight | E7515A UXM Wireless Test Set - Data Sheet
W-CDMA/HSPA+ Measurements
Modulation, bands, and frequency
Modulation types
Downlink
QPSK, 16QAM, 64QAM
Uplink
QPSK, 16QAM
Bands
1 to 14, 19 to 21, 25, 26
Frequency range
0.7 to 2.7 GHz (within bands)
W-CDMA/HSPA+ signal generation
Modulated output power range
TxRx1, TxRx2
–110 to –13 dBm/3.84 MHz
Tx1, Tx2
–110 to –5 dBm/3.84 MHz
Output level accuracy with QPSK or 16QAM
±0.7 dB, typical
W-CDMA/HSPA+ measurements
Level ranges
Channel power, frequency error
–61 to +28 dBm/3.84 MHz
ACLR, OBW, SEM
+5 to +28 dBm/3.84 MHz
EVM
–25 to +28 dBm/3.84 MHz
Channel power accuracy
±0.7 dB, typical
Adjacent channel leakage ratio (ACLR) accuracy
±0.7 dB, nominal
Spectrum emissions mask (SEM) accuracy
±1.5 dB, nominal
Occupied bandwidth (OBW) accuracy
<100 kHz, nominal
Error vector magnitude (EVM) accuracy
<2.5% RMS, nominal
Frequency error accuracy
<10 Hz, nominal
10 | Keysight | E7515A UXM Wireless Test Set - Data Sheet
From Hewlett-Packard through Agilent to Keysight
For more than 75 years, we‘ve been helping you unlock measurement insights. Our
unique combination of hardware, software and people can help you reach your next
breakthrough. Unlocking measurement insights since 1939.
1939
THE FUTURE
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s committed to superior product quality and lower total cost
of ownership. Keysight is the only test and measurement company with
three-year warranty standard on all instruments, worldwide. And, we provide
a one-year warranty on many accessories, calibration devices, systems and
custom products.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to ten years of protection and no budgetary surprises to ensure your
instruments are operating to specification, so you can rely on accurate
measurements.
Keysight Infoline
www.keysight.com/find/service
Keysight’s insight to best in class information management. Free access to
your Keysight equipment company reports and e-library.
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
www.keysight.com/find/uxm
www.keysight.com/find/e7515a
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
55 11 3351 7010
001 800 254 2440
(800) 829 4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 11 2626
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 6375 8100
Europe & Middle East
Austria
Belgium
Finland
France
Germany
Ireland
Israel
Italy
Luxembourg
Netherlands
Russia
Spain
Sweden
Switzerland
United Kingdom
0800 001122
0800 58580
0800 523252
0805 980333
0800 6270999
1800 832700
1 809 343051
800 599100
+32 800 58580
0800 0233200
8800 5009286
800 000154
0200 882255
0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-02-10-16)
DEKRA Certified
ISO9001 Quality Management System
www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2015
Quality Management System
This information is subject to change without notice.
© Keysight Technologies, 2014 - 2016
Published in USA, July 18, 2016
5991-4634EN
www.keysight.com