AIMTEC AM3HW-NZ Input to output isolation of 1500vdc Datasheet

Series AM3HW-NZ
3 Watt | DC-DC Converter
Picture coming soon
FEATURES:
•
•
•
•
•
•
•
•
•
•
SMD Package
Ultra-wide input range 4:1
High efficiency up to 84%
Low ripple and noise
Remote On/Off Control
No load power consumption ≤0.12W
Input to Output Isolation of 1500VDC
Input under voltage lockout
Over current and Short circuit protection
Operating temperature of -40 to +85°C
Models
Single output
Model
Input
Voltage (V)
Max Input
current full
load (mA)
Output
Voltage
(V)
Output
Current max
(mA)
Isolation
(VDC)
Max
Capacitive
Load (uF)
Efficiency
(%)
AM3HW-2405S-NZ
AM3HW-2412S-NZ
AM3HW-2415S-NZ
AM3HW-2424S-NZ
AM3HW-4815S-NZ
9-36
9-36
9-36
9-36
18-75
173
173
173
173
81
5
12
15
24
15
600
250
200
125
200
1500
1500
1500
1500
1500
2200
680
470
100
470
80
82
83
82
84
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
Typical
24
48
Filter
Start up time
Absolute Maximum Rating
24
48
Units
VDC
ms
-0.7 - 50
-0.7 - 100
1
ON – open or 3.5-12VDC ; OFF – short to –Vin or 0-1.2VDC,
Idle current: 6-10mA
6
5
Peak Input Voltage time
On/Off control
No Load Input Current
Maximum
9-36
18-75
Capacitor
10
24
48
Rise time
VDC
s
mA
ms
Under voltage lockout
Input reflected ripple current
24
48
24
48
6.5
15.5
120
60
Conditions
Typical
60 sec, 1mA
500VDC Isolation
100KHz/0.1V
1500
>1000
1000
VDC
mA
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Maximum
Units
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Over current protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
www.aimtec.com
F 051e R13
Conditions
Full load, LL-HL
0% to 100% load
Typical
±1
150
Continuous, hiccup
Auto-recovery
±0.2
±0.5
Tel: +1 514 620 2722
1 of 3
Maximum
Units
±3
250
%
% of Iout
±0.5
±1
±0.03
% of Vin
%
o
%/ C
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM3HW-NZ
3 Watt | DC-DC Converter
Output Specifications (continued)
Parameters
Conditions
Ripple & Noise*
Transient recovery time
Transient recovery deviation
Typical
Maximum
Units
300
±3
120
500
±5
mV p-p
µs
%
Conditions
Typical
Maximum
Units
100% load
Derating above 71°C
350
20MHz Bandwidth, 5% to 100% load
25% load step change
25% load step change
* 0-5% load up to 5% of Vout.
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
-40 to +85
-55 to +125
105
KHz
o
C
o
C
o
C
Free air convection
95
% RH
Black flame retardant heat proof plastic (UL94-V0)
3.5
g
0.76 x 0.71 x 0.4 inches
19.20 x 18.10 x 10.16 mm
o
>1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25 C)
Look at the SMD soldering profile: http://www.aimtec.com/rohs-soldering-profiles
Environment Specification
Test
Parameters
Test mode
Acceleration
Vibration
Conditions
10-55Hz
10g, 30min, every axis tested
Safety Specifications
Parameters
Meets IEC60950-1
Meet EN 55022, Class B, with external filter & EN 55024: 2010
IEC 61000-4-2, Contact ±4KV, Criteria B
IEC 61000-4-3, 10V/m, Criteria A
IEC 61000-4-4, ±2KV, Criteria B, with external filter
IEC 61000-4-5, ±2KV, Criteria B, with external filter
IEC 61000-4-6, 3Vrms, Criteria A
IEC 61000-4-29, 0-70%, Criteria B
Standards
Derating
Free Air Convection
71º C
Output Power (%)
100
80
Safe Operating Area
60
40
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com
F 051e R13
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM3HW-NZ
3 Watt | DC-DC Converter
Pin Out Specifications
Dimensions
Top View
Pin
1
2
6
7
8
9
14
Single
-Vin
On/Off Control
NC
NC
+Vout
-Vout
+Vin
19.20
(0.76)
Side View
14
9
8
10.16
(0.40)
1.00
(0.04)
18.10
(0.71)
2.54
(0.10)
6
2
15.24
(0.60)
1.00
(0.04)
All dimensions are in mm (inch)
Pin tolerance: ±0.10 (±0.004)
Case tolerance of ±0.50 (±0.02)
7
EMC recommended circuit:
+Vin
LDM
12µH
F1
MOV
-Vin
C1
C2
C3
C5
C4
DC-DC Converter
+Vo
-Vo
CY1
1nF/2KV
Model
MOV
24 Vin
S14K35
48 Vin
S14K60
C1 & C2
330 µF /
50V
330 µF /
100V
C3 &C4
4.7 µF /
50V
4.7 µF /
100V
C3
10 µF
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4 . All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R13
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC