TRIAD F12-1000 Pc mount : split pack Datasheet

P OWE R T RAN S FO R M E R
P C M O U N T : SPLIT PACK
F12-1000
.
Description:
The F12-1000 is a single primary and dual secondary, split bobbin design which
operates with an input of 115V. The output voltage will be either 12.6V with a
center-tap under a 1.0A load with the secondaries wired in series, or 6.3V under
a 2.0A load with the secondaries wired in parallel. The split bobbin design
eliminates the need for costly electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 12.0VA
2. Primary:
115V
3. Secondary: Series: 12.6V CT@ 1.0A
Parallel: 6.3V @ 2.0A
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 25C TYP
6. Hipot tested 100% at 2500 VRMS
W
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling.
Agency File:
UL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
cUL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
Canadian Use (CSA 22.2, No.66.2-06)
E
This model is also available in Class 2, UL 5085-3 (1585) version as F12-1000-C2
Dimensions:
H
W
1.437 1.562
Weight: 0.70 lbs
L
Units in inches.
L
1.875
A
0.300
B
0.400
C
1.410
D
0.041
E
0.020
H
F
0.234
1
4
Schematic:
D
5
F
1
115V
50/60Hz
4
6
7
A
A
5
8
8
B
RoHS Compliance: As of manufacturing date February 2005, all standard products
meet the requirements of 2011/65/EU, known as the RoHS initiative.
C
As of April 7, 2008, UL standards 506 and 1585 will be migrated to UL 5085-2 and
5085-3, respectively.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’
website for the most current version.
1
4
0.06" DIAMETER
HOLE
Board Layout
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013
Similar pages