12W Me d i c a l Gr ade Wall m ount S w i t c hi ng Po we r Ad a p te rs AMP1201 series Wide Universal 80-275VAC Input UL/EN/IEC60601-1 3rd Edition Approvals; 2MOPP Over Voltage & Over Load Protection 4000VAC Isolation Class II, 2 Prong U.S. Input Efficiency Level V 2.56” x 2.17” x 1.40” RoHS2 2011/65/EU Model Number Output Watts Output Voltage Output Amps Total Regulation (Note 2) Efficiency AMP1201-02 AMP1201-03 AMP1201-04 AMP1201-05 AMP1201-06 AMP1201-07 AMP1201-08 10 12 12 12 12 12 12 5VDC 6VDC 9VDC 12VDC 15VDC 18VDC 24VDC 2.0 2.0 1.33 1.0 0.8 0.66 0.5 ± 5% ± 5% ± 5% ± 5% ± 5% ± 3% ± 3% 74% 76% 79% 79% 81% 81% 81% WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 12W Me d i c a l Gr ade Wall m ount S w i t c hi ng Po we r Ad a p te rs 80-275 VAC (100-240V Nominal) 47-63 Hz Low Line (100VAC) 0.29A max. High Line (240VAC) 0.16A max. Low Line (100VAC) 50A max. High Line (230VAC) 100A max. <100 uA Double Insulated, Class II 0.3W OUTPUT SPECIFICATIONS Voltage and Current Output Power Range Line Regulation (FL) (Note 1) Over Voltage Protection Over Load Protection Transient Response Temperature Coefficient Ripple/Noise (Note 3) Short Circuit Protection Start Up / Hold Up Time See Selection Chart 0 to FL Rating ± 1%, max. 112-132% 110-150% Auto-Recovery 110Vin, FL 4mS ±0.04%/°C, typ FL, 90Vin 1% Pk-Pk max. Continuous, self-recovering * 100Vin, FL 2S max. / 16mS min. GENERAL SPECIFICATIONS Input-Out Isolation Efficiency (FL, Nom. Vin) Safety series PHYSICAL SPECIFICATIONS INPUT SPECIFICATIONS Input Voltage Range Frequency Range Input Current Inrush Current, typ (Cold Start) Leakage Current Protection Class No Load Power Consumption AMP1201 4000 VAC See Selection Chart ANSI/AAMI ES 60601-1:2005 (UL/cUL/EN/IEC 3rd Edition) All specifications are typical at nominal input, full load, and 25°C unless otherwise noted WWW.ASTRODYNETDI.COM Size Construction Weight 2.56” x 2.17” x 1.40” (65x55x35.6mm) Wallmount Style 5.64oz (160g) ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Cooling Flammability Rating Storage Temperature Operating/Storage Humidity EMC MTBF (MIL-HDBK-217F, 25 °C) Efficiency Level Surge Voltage ESD Air: Contact: Operating Altitude Vibration -10 to +50°C (FL) * 50% Load @ 70°C (See Derate Curve Next Page) Free Air Convection UL94V-1 -40 to +85°C (10-95% RH) * 0% to 95%, non-cond * Compliance to EN55011 (CISPR11), EN61000-3-2,-3 Class B 100,000 Hrs min. V 2kV min. IEC61000-4-2, 8kV min. IEC61000-4-2, 6kV min. 3000M max. 10 ~ 500Hz, 10min./1cycle, 60min. each along X, Y, Z axes, 5G min NOTES 1. Line Regulation defined as changing the input voltage ±10% from nominal line at rated load. 2. Total Regulation is defined by as changing the load ±40% from 60% rated load. 3. Ripple & Noise is measured by using a 20MHz bandwidth limited oscilloscope and terminating the output with a 0.47uF capacitor at rated load and nominal line. * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 oscilloscope and terminated each output with a 0.47uF capacitor at rated load and nominal line. 6. Hold up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at rated load and nominal line. 7. Efficiency is measured at rated load, and nominal line. 8. The specifics for testing the energy efficiency of this Series are outlined in a separate document titled "Test Method for Calculating the Energy Efficiency of Single-Voltage Interchangeable AC-DC and AC-AC Power Supplies (August 11, 2004)," which is available on the ENERGY STAR Website. 50 80 100 120 140 160 180 200 220 INPUT VOLTAGE (VAC) (FIG.1) INPUT VOLTAGE DERATING CURVE 240 260 280 110 100 90 80 70 60 AMP1201 50 40 12W Me d i c a l Gr ade Wall m ount S w i t c hi ng Po we r Ad a p te rs 30 20 series 10 MECHANICAL DIMENSIONS 0 -10 0 20 30 40 50 TEMPERATURE (°C) (FIG.2) TEMPERATURE DERATING CURVE 10 Dimensions Are In mm. MECHANICAL DIMENSIONS: ( UNIT: mm ) 60 70 80 OUTPUT CABLE RECOMMEND : 1. Selected output connectors and wire, please refer to Appendix. 2. MPU12A-102~103 are required to use AWG#18/6FT output cable. 3. MPU12A-104~108 are required to use AWG#20/6FT output cable. 4. The regulation and efficiency will be changed by modified output cable. PACKING : 1. Net weight: 130g approx. 2. Optional output connectors available contact sales for details. DC OUTPUT CONNECTIONS -Vout Coaxial Plug: +Vout 5.5mm outer diameter 2.1mm inner diameter, female 11mm length, center “+” Rating Chart: Ripple & Noise Total Regulation Typ. Efficiency No Load Consumption Hold-Up Time (VDC) (A) (A) (W) (mVp-p) (%) (%) (W) (ms) 5.0 5.99 1.66 2.00 10 50 ±5 74 0.3 12 OLP MPU12A-103 6.0 8.0 1.50 2.00 12 60 ±5 76 0.3 12 OLP 8.0 11.0 1.09 1.50 12 80 ±5 79 0.3 12 OLP 80 MPU12A-105 11.0 13.0 0.92 1.09 12 100 ±5 79 0.3 12 OLP MPU12A-106 70 13.0 16.0 0.75 0.92 12 100 ±5 81 0.3 12 OLP MPU12A-107 16.0 21.0 0.57 0.75 12 100 ±3 81 0.3 12 OLP 21.0 27.0 0.44 0.57 12 100 ±3 81 0.3 12 OLP Output Current (Based on the output volt.) MODEL NO. DERATE CURVES 12W External Medical Grade Supply min max Powermin 110 90 LOAD (%) MPU12A-104 60 MPU12A-108 max Protection Mode Maximum Output Power (VDC) MPU12A-102 100 Voltage Range 50 80 100 -10 0 120 140 160 180 200 220 INPUT VOLTAGE (VAC) (FIG.1) INPUT VOLTAGE DERATING CURVE 240 260 280 110 100 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 TEMPERATURE (°C) (FIG.2) TEMPERATURE DERATING CURVE 60 70 80 OUTPUT CABLE RECOMMEND : 1. Selected output connectors and wire, please refer to Appendix. 2. MPU12A-102~103 are required to use AWG#18/6FT output cable. 3. MPU12A-104~108 are required to use AWG#20/6FT output cable. 4. The regulation and efficiency will be changed by modified output cable. WWW.ASTRODYNETDI.COM PACKING : 1. Net weight: 130g approx. 5214 ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458