VIMARLOW NL1025T-02AC Single-stage thermoelectric cooler Datasheet

TECHNICAL DATA SHEET
NL1025T
Single-Stage Thermoelectric Cooler
RoHS EU Compliant
TYPICAL PERFORMANCE VALUES
Hot Side Temperature (°C)
Δ Tmax (°C-dry N2):
Qmax (watts):
Imax (amps):
Vmax (vdc):
AC Resistance (ohms):
27°C
64
5.2
1.8
4.4
2.1
50°C
73
5.8
1.8
4.9
--
MECHANICAL CHARACTERISTICS
-05 ONLY: RED LEADWIRES, SOLID
-07 ONLY: WHITE LEADWIRES, STRANDED
POSITIVE LEAD (+)
LEADS: 28AWG
UN-INSULATED SOLID TINNED COPPER
-05, -07 ONLY: TEFLON INSULATED, SILVER PLATED COPPER
.346
[8.79]
NEGATIVE LEAD (-)
.432
[10.97]
-05 ONLY: BLACK LEADWIRES, SOLID
-07 ONLY: BLACK LEADWIRES, STRANDED
2.00±.25
[50.8±6.4]
-05 ONLY: 7.00±.25
[177.8±6.4]
-07 ONLY: 5.00±.25
[127.8±6.4]
COLD SIDE, Tc
.004 [0.10] A
.001 [0.03]
.001 [0.03]
.085±.005
[2.16±0.13]
CERAMIC MATERIAL: ALUMINA (AC)
MILLIMETERS ARE IN [ ]
ORDERING OPTIONS
PRODUCT FEATURES
Model Number
Description
NL1025T-01AC
NL1025T-02AC
NL1025T-03AC
NL1025T-05AC
NL1025T-06AC
NL1025T-07AC
Both Surfaces are Metallized
Hot Side Exterior is Metallized
No Metallization
No Metallization, Insulated 7 Inch Leadwire
No Metallization, RTV Sealed
No Metallization, Insulated 5 Inch Leadwire
•
•
•
Pretinned Metallized Ceramic Surface(s) with 117°C solder.
Thermistor mounted on edge of cold side ceramic.
(Calibration available.)
Elevated temperature burn-in with test data provided.
For customer support or general questions please contact a local office or visit our website at www.marlow.com.
DOC # 102-0298 REV L - PAGE 1 OF 2
ENVIRONMENT: ONE ATMOSPHERE DRY NITROGEN
40.0
20.0
0.0
80.0
60.0
T (C)
60.0
T (C)
Hot Side Temperature 50°C
HEAT
LOAD
(WATTS)
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
5.00
80.0
0.0
HEAT
LOAD
(WATTS)
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
5.00
5.50
Q=0
T=0
2.0
1.0
VOLTAGE (VDC)
5.0
3.0
0.0
0.0
40.0
20.0
4.0
VOLTAGE (VDC)
TYPICAL PERFORMANCE CURVES
Hot Side Temperature 27°C
4.0
3.0
Q=0
T=0
2.0
1.0
0.4
0.8
1.2
CURRENT (AMPS)
1.6
2.0
0.0
0.0
0.4
0.8
1.2
CURRENT (AMPS)
1.6
2.0
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, contact one of our Applications Engineers at
877-627-5691.
Installation
Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional information,
please refer to our TEC Installation Guide.
Operation Cautions
For maximum reliability, storage and operation below 85°C in a non-condensing environment is recommended. To minimize thermal
stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method.
CONTACT US:
For customer support or general questions please contact a local office below or visit our website at www.marlow.com.
Marlow Industries, Inc.
10451 Vista Park Road
Dallas Texas 75238-1645
214-340-4900 (tel)
214-341-5212 (fax)
877-627-5691 (tech support)
www.marlow.com
Marlow Industries Europe GmbH
Brunnenweg 19-21
64331 Weiterstadt
Germany
Tel.: +49 (0) 6150 5439 - 403
Fax: +49 (0) 6150 5439 - 400
[email protected]
II-VI Japan Inc.
WBG Marive East 17F
2-6 Nakase, Mihama-ku
Chiba-Shi, Chiba 261-7117
Japan
81 43 297 2693 (tel)
81 43 297 3003 (fax)
[email protected]
www.ii-vi.co.jp
II-VI Singapore Pte., Ltd.
Blk. 5012, Techplace II
#04-07 & 05-07/12, Ang Mo Kio Ave. 5
Singapore 569876
(65) 6481 8215 (tel)
(65) 6481 8702 (fax)
[email protected]
www.ii-vi.com.sg
Marlow Industries China, II-VI
Technologies Beijing
A subsidiary of II-VI Incorporated
Rm 202, 1# Lize 2nd Middle Road
Wangjing, Chaoyang District
Beijing 100102 China
010-64398226 ext 105 (tel)
010-64399315 (fax)
[email protected]
DOC # 102-0298 REV L - PAGE 2 OF 2