Series AM15C-Z 15Watt | DC-DC Converter FEATURES: • • • • • • • • • • Ultra compact footprint 1”x1” Wide Input Range 2:1 1600 VDC Isolation Remote ON/OFF Function No Minimum Load Required Adjustable Output Voltage Operating Temperature -40ºC to +85ºC Over Current and Over Voltage Protection Efficiency up to 89% RoHS Compliant Models Single output Model Input Voltage (V) AM15C-1203SZ AM15C-1205SZ AM15C-1212SZ AM15C-1215SZ AM15C-2403SZ AM15C-2405SZ AM15C-2412SZ AM15C-2415SZ AM15C-4803SZ AM15C-4805SZ AM15C-4812SZ AM15C-4815SZ 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 Output Voltage (V) 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 Output Current max (A) 4 3 1.3 1 4 3 1.3 1 4 3 1.3 1 Isolation (VDC) Max Capacitive Load (uF) Efficiency (%) 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 1000 1000 330 220 1000 1000 330 220 1000 1000 330 220 84 86 85 87 86 87 88 89 84 86 87 88 Isolation (VDC) Max Capacitive Load (uF) Efficiency (%) Models Dual output Model Input Voltage (V) Output Voltage (V) Output Current max (A) AM15C-1205DZ 9-18 ±5 ±1.5 1600 ±470 85 AM15C-1212DZ 9-18 ±12 ±0.625 1600 ±220 87 AM15C-1215DZ 9-18 ±15 ±0.5 1600 ±100 88 AM15C-2405DZ 18-36 ±5 ±1.5 1600 ±470 85 AM15C-2412DZ 18-36 ±12 ±0.625 1600 ±220 88 AM15C-2415DZ 18-36 ±15 ±0.5 1600 ±100 89 AM15C-4805DZ 36-75 ±5 ±1.5 1600 ±470 84 AM15C-4812DZ 36-75 ±12 ±0.625 1600 ±220 87 AM15C-4815DZ 36-75 ±15 ±0.5 1600 ±100 88 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Filter Start up time Absolute Maximum Rating Nominal Typical 12 24 48 9-18 18-36 36-75 www.aimtec.com F 051e R11.C Units VDC π Nominal Vin with constant resistive load 12 Vin 24 Vin 48 Vin Peak Input Voltage time On/Off control Maximum 20 ms 36 50 100 100 VDC ms ON –3 to 12VDC (or open) OFF – 0 to 1.2VDC or short pin 2 to pin 3; OFF idle current – 5mA Tel: +1 514 620 2722 1 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM15C-Z 15Watt | DC-DC Converter Input Specifications (continued) Parameters Nominal Typical No load current Under voltage lockout 12 Vin ON/OFF 24 Vin ON/OFF 48 Vin ON/OFF Maximum Units 15 mA 8.5 /7 17/15 34/35 20 Input reflected ripple current VDC mA p-p Isolation Specifications Parameters Tested I/O voltage Case to Input Case to Output Resistance Capacitance Conditions Typical 3 sec 3 sec 3 sec Rated Units 1600 VDC VDC VDC MOhm pF Maximum Units 1600 1600 >1000 1200 Output Specifications Parameters Conditions Typical Voltage accuracy Cross Regulation (Dual Output Models) Over voltage protection Over current protection Short Circuit protection Short circuit restart Line voltage regulation Load voltage regulation (Single) Load voltage regulation (Dual) Temperature coefficient Ripple & Noise Voltage adjustment range 25% load on one output - 100% load on second load Zener Diode Clamp Full Load HL-LL 0% to 100% load 0% to 100% balanced load 20MHz Bandwidth Trim - Single output models only ±1 % ±5 % 120 170 Continuous Auto-Recovery ±0.2 ±0.5 ±1 ±0.02 100 ±10 % % % % % o %/ C mV p-p % General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Derating Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Transient recovery time Transient recovery deviation www.aimtec.com F 051e R11.C Conditions Typical 100% load With derating above +65°C -40 to +125 Maximum 375 -40 to +85 105 2.6 Free air convection 95 Nickel-coated copper 18 1.00 x 1.00 x 0.40 inches 25.40 x 25.40 x 10.16 mm o > 560,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25 C) 1.5mm from case for 10 sec 260 Load step change 75% to 50% to 25% 250 Load step change 75% to 50% to 25% ±3 Tel: +1 514 620 2722 2 of 4 Units KHz o C o C o C o %/ C % RH g o C µS % Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM15C-Z 15Watt | DC-DC Converter Safety Specifications Parameters Agency Approvals Standards CE EN 55022 Class A EN 61000-4-2 Perf. Criteria A EN 61000-4-3 Perf. Criteria A EN 61000-4-4 Perf. Criteria A (external 220uF/100V cap required) EN 61000-4-5 Perf. Criteria A (external 220uF/100V cap required) EN 61000-4-6 Perf. Criteria A EN 61000-4-8 Perf. Criteria A NOTE: also designed to meet IEC 60950-1:2001 Test Circuits Notes 1. Input filter (C1, C2, L) are needed to meet conducted emission (EN 55022 Class A) and should be mounted as close as possible to the converter. L 12uH +V input +V output + C1 2.2uF/100V C2 2.2uF/100V DC/DC Converter - V input Load -V output Pin Out Specifications Pin 1 2 3 4 5 6 Single + V input - V input On/Off Control + V output Trim - V output www.aimtec.com F 051e R11.C Dual + V input - V input On/Off Control + V output Common - V output Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM15C-Z 15Watt | DC-DC Converter Dimensions Bottom View 2.54 (0.10) Top View 25.40 (1.00) 10.16 2.54 (0.40) (0.10) 10.16 (0.40) 5 4 6 20.32 (0.80) 25.40 (1.00) +V Output Trim -V Output +V -V Input Input CTRL 2.54 (0.10) 1 Side View 10.16 (0.40) 2 3 5.08 7.62 (0.20) (0.30) 9.90 (0.39) Printed Face 2.54 (0.10) 1.00 (0.39) Derating Trimming Free Air Convection 65 ºC Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R11.C Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only