MPD MG212DMR-15RI4 Medical approved compact minidip, 2w dc/dc converter Datasheet

MG200MRRI4
Medical Approved
Compact MiniDIP, 2W
DC/DC Converters
Key Features:
Electrical Specifications
• EN 60601 3RD Ed. Approved Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• 2W Output Power
Parameter
Conditions
Min.
Typ.
Max.
Units
• 4.0 kVrms Isolation
• Reinforced Insulation
Input Voltage Range
• 1 x MOPP & 2 x MOOP per Input Filter
EN 60601-1 3RD Edition & Output
Parameter
ANSI/AAMI ES 60601-1
Output Voltage Accuracy
• 2 µA Leakage Current Max
Output Voltage Balance
• Compact MiniDIP Case
Line Regulation
• Single & Dual Outputs
Load Regulation, See Note 2
Ripple & Noise (20 MHz)
• 2.0 MH MTBF
Temperature Coefficient
Output Short Circuit
5 VDC Input
4.5
5.0
12 VDC Input 10.8
12.0
24 VDC Input 21.6
24.0
Internal Capacitor
Conditions
Typ.
±2.0
Dual Outputs, Balanced Loads
±0.1
VIN = Min to Max
±1.2
See Model Selection Guide
See Note 3
100
±0.01
0.5 Sec. Max (Autorecovery)
5.5
13.2
26.4
VDC
Max.
±4.0
±1.0
±1.5
Units
%
%
%
150
±0.02
mV P - P
%/°C
Max.
Units
Vrms
2.0
µA
G⍀
pF
kHz
Min.
General
Parameter
Isolation Voltage, Rated
Reinforced Insulation Working Voltage
Leakage Current
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
Min.
60 Seconds 4,000
300 Vrms
500 VDC
100 kHz, 1V
Typ.
10
50
15
80
20
100
EMI Characteristics
Parameter
EMC
EMS
Standard
Criteria
Complies With EN 55011 4TH Edition
Complies With EN 60601-1-2
Level
Environmental
Parameter
Conditions
Ambient
Case
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
MicroPower Direct
Reliability Specifications
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
MTBF
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Min.
-25
Typ.
-50
Free Air Convection
RH, Non-condensing
Max.
+80
+105
+125
Units
°C
°C
°C
95
%
See Mechanical Diagram (Page 2)
Non-Conductive Black Plastic (UL94-V0)
0.18 Oz (5.1g)
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
2.0
MHours
IEC/EN 60601-1, EN 60601-1 3RD Edition, 1xMOPP & 2xMOPP
ANSI/AAMI ES 60601-1 1xMOPP & 2xMOPP Recognition (UL Certificate)
ANSI/AAMI ES 60601-1, CAN/CSA-C22.2 No.60601-1
Safety Standards
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Min.
Typ.
5 VDC Input
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec
Max.
9.0
18.0
30.0
260
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Model
Number
MG205SMR-05RI4
MG205SMR-12RI4
MG205SMR-15RI4
MG205DMR-12RI4
MG205DMR-15RI4
MG212SMR-05RI4
MG212SMR-12RI4
MG212SMR-15RI4
MG212DMR-12RI4
MG212DMR-15RI4
MG224SMR-05RI4
MG224SMR-12RI4
MG224SMR-15RI4
MG224DMR-12RI4
MG224DMR-15RI4
Input
Output
Current
Voltage (VDC)
Current (mA)
Voltage
(mA, Max)
Nominal Range Full-Load No-Load (VDC)
5
4.5 - 5.5
606
60
5.0
400.0
5
4.5 - 5.5
600
60
12.0
165.0
5
4.5 - 5.5
605
60
15.0
133.0
5
4.5 - 5.5
553
60
±12.0
±83.0
5
4.5 - 5.5
542
60
±15.0
±66.0
12
10.8 - 13.2
253
30
5.0
400.0
12
10.8 - 13.2
250
30
12.0
165.0
12
10.8 - 13.2
252
30
15.0
133.0
12
10.8 - 13.2
224
30
±12.0
±83.0
12
10.8 - 13.2
220
30
±15.0
±66.0
24
21.6 - 26.4
126
15
5.0
400.0
24
21.6 - 26.4
125
15
12.0
165.0
24
21.6 - 26.4
126
15
15.0
133.0
24
21.6 - 26.4
112
15
±12.0
±83.0
24
21.6 - 26.4
110
15
±15.0
±66.0
Notes:
1. The specified maximum capacitive load is for each output.
2. Load regulation is measured for a load change of 20% to 100%.
3. When measuring output ripple, it is recommended that an external 0.47 µF ceramic capacitor be
placed from the +VOUT pin to the -VOUT pin for single output units and from each output to common
for dual output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the
output ripple.
4. Operation at no-load will not damage these units. However, they may not meet all specifications.
5. For dual output units, the maximum capacitive load is given for each output.
6. The converter should be connected to a low ac-impedance source. An input source with
a highly inductive impedance may affect the stability of the converter. In applications
where the converter output loading is high and input power is supplied over long lines,
it may be necessary to use a capacitor on the input to insure start-up. In this case, it
is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor be mounted close
to the converter. For 5V input units a 2.2 µF is recommended, for 12V input units, a
1.0 µF; and for 24V units a 0.47 µF.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the
table above for the correct rating.
Current
(mA, Min)
Capacitive
Load
Rating
Efficiency Fuse
Slow-Blow
Load
Regulation (%, Typ)
(mA)
8.0
3.0
2.5
±1.5
±1.0
8.0
3.0
2.5
±1.5
±1.0
8.0
3.0
2.5
±1.5
±1.0
(µF, Max)
(%, Max)
330
330
330
100
100
330
330
330
100
100
330
330
330
100
100
12
10
10
10
10
12
10
10
10
10
12
10
10
10
10
66
66
66
72
73
66
66
66
74
75
66
66
66
74
75
1,200
1,200
1,200
1,200
1,200
500
500
500
500
500
250
250
250
250
250
Derating Curve
Mechanical Dimensions
Pin Co
Connections
Pin
Single
Dual
1
-Vin
-Vin
7
NC
NC
8
NC
Common
9
+Vout
+Vout
10
-Vout
-Vout
16
+Vin
+Vin
NC = No Co
Connection
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages