Ferroxcube E14-3C90 Planar e cores and accessory Datasheet

FERROXCUBE
DATA SHEET
E14/3.5/5
Planar E cores and accessories
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
Planar E cores and accessories
E14/3.5/5
CORES
Effective core parameters of a set of E cores
SYMBOL
PARAMETER
VALUE
UNIT
Σ(I/A)
core factor (C1)
1.43
mm −1
Ve
effective volume
300
mm 3
Ie
effective length
20.7
mm
Ae
effective area
14.3
mm 2
Amin
minimum area
14.3
mm 2
m
mass of core half
≈ 0.6
g
14 ± 0.3
handbook, halfpage
11 ± 0.25
3
± 0.05
2 ± 0.1
3.5 ± 0.1
5 ± 0.1
MBE644
R 0.8 (12x)
Dimensions in mm.
Fig.1 E14/3.5/5 core.
Effective core parameters of an E/PLT combination
SYMBOL
PARAMETER
VALUE
UNIT
Σ(I/A)
core factor (C1)
1.16
mm −1
Ve
effective volume
240
mm 3
Ie
effective length
16.7
mm
Ae
effective area
14.5
mm 2
Amin
minimum area
14.5
mm 2
m
mass of plate
≈ 0.5
g
handbook, halfpage
14 ± 0.3
1.5 ± 0.05
Ordering information for plates
GRADE
TYPE NUMBER
3C90
PLT14/5/1.5-3C90
3C92
PLT14/5/1.5-3C92
3C93
PLT14/5/1.5-3C93
3C94
PLT14/5/1.5-3C94
3C95
PLT14/5/1.5-3C95
3C96
PLT14/5/1.5-3C96
3F3
PLT14/5/1.5-3F3
3F35
PLT14/5/1.5-3F35
3F4
PLT14/5/1.5-3F4
3F45
PLT14/5/1.5-3F45
3E6
PLT14/5/1.5-3E6
2008 Sep 01
5 ± 0.1
R 0.8
MBE652
Dimensions in mm.
Fig.2 PLT14/5/1.5.
2
Ferroxcube
Planar E cores and accessories
E14/3.5/5
Core halves for use in combination with an ungapped E core
AL measured in combination with a non-gapped core half, clamping force for AL measurements, 10 ±5 N, using a PCB
coil containing 4 layers of 8 tracks each, total height 1.6 mm.
GRADE
3C90
AL
(nH)
µe
63 ±3%
≈ 72
≈ 530
E14/3.5/5-3C90-A63-E
100 ±5%
≈ 114
≈ 270
E14/3.5/5-3C90-A100-E
E14/3.5/5-3C90-A160-E
160 ±8%
AIR GAP
(µm)
TYPE NUMBER
≈ 182
≈ 130
1280 ±25%
≈ 1450
≈0
E14/3.5/5-3C90
3C92
960 ±25%
≈ 1090
≈0
E14/3.5/5-3C92
3C93
1100 ±25%
3C94
≈ 1250
≈0
63 ±3%
≈ 72
≈ 530
E14/3.5/5-3C94-A63-E
100 ±5%
≈ 114
≈ 270
E14/3.5/5-3C94-A100-E
E14/3.5/5-3C94-A160-E
160 ±8%
E14/3.5/5-3C93
≈ 182
≈ 130
1280 ±25%
≈ 1450
≈0
E14/3.5/5-3C94
3C95
1500 ±25%
≈ 1730
≈0
E14/3.5/5-3C95
3C96
1200 ±25%
≈ 1360
≈0
E14/3.5/5-3C96
3F3
63 ±3%
≈ 72
≈ 530
E14/3.5/5-3F3-A63-E
100 ±5%
≈ 114
≈ 270
E14/3.5/5-3F3-A100-E
160 ±8%
≈ 182
≈ 130
E14/3.5/5-3F3-A160-E
1100 ±25%
≈ 1250
≈0
E14/3.5/5-3F3
3F35
900 ±25%
≈ 1020
≈0
E14/3.5/5-3F35
3F4
63 ±3%
≈ 72
≈ 530
3F45
3E6
2008 Sep 01
E14/3.5/5-3F4-A63-E
100 ±5%
≈ 114
≈ 270
E14/3.5/5-3F4-A100-E
160 ±8%
≈ 182
≈ 130
E14/3.5/5-3F4-A160-E
650 ±25%
≈ 740
≈0
E14/3.5/5-3F4
≈ 740
≈0
E14/3.5/5-3F45
≈ 6360
≈0
E14/3.5/5-3E6
650 ±25%
5 600 +40/−30%
3
Ferroxcube
Planar E cores and accessories
E14/3.5/5
Core halves for use in combination with a plate (PLT)
AL measured in combination with a plate (PLT) clamping force for AL measurements, 10 ±5 N, using a PCB coil
containing 4 layers of 8 tracks each, total height 1.6 mm.
GRADE
3C90
AL
(nH)
µe
63 ±3%
≈ 58
≈ 600
E14/3.5/5-3C90-A63-P
100 ±5%
≈ 92
≈ 300
E14/3.5/5-3C90-A100-P
E14/3.5/5-3C90-A160-P
160 ±8%
AIR GAP
(µm)
TYPE NUMBER
≈ 148
≈ 150
1500 ±25%
≈ 1400
≈0
E14/3.5/5-3C90
3C92
1130 ±25%
≈ 1040
≈0
E14/3.5/5-3C92
3C93
1300 ±25%
3C94
≈ 1200
≈0
63 ±3%
≈ 58
≈ 600
E14/3.5/5-3C94-A63-P
100 ±5%
≈ 92
≈ 300
E14/3.5/5-3C94-A100-P
E14/3.5/5-3C94-A160-P
E14/3.5/5-3C93
160 ±8%
≈ 148
≈ 150
1500 ±25%
≈1400
≈0
E14/3.5/5-3C94
3C95
1740 ±25%
≈ 1600
≈0
E14/3.5/5-3C95
3C96
1350 ±25%
≈ 1260
≈0
E14/3.5/5-3C96
3F3
3F35
3F4
63 ±3%
≈ 58
≈ 600
E14/3.5/5-3F3-A63-P
100 ±5%
≈ 92
≈ 300
E14/3.5/5-3F3-A100-P
160 ±8%
≈ 148
≈ 150
E14/3.5/5-3F3-A160-P
1300 ±25%
≈ 1200
≈0
E14/3.5/5-3F3
1050 ±25%
≈ 980
≈0
E14/3.5/5-3F35
≈ 58
≈ 600
63 ±3%
100 ±5%
≈ 92
≈ 300
E14/3.5/5-3F4-A100-P
160 ±8%
≈ 148
≈ 150
E14/3.5/5-3F4-A160-P
780 ±25%
≈ 720
≈0
≈ 720
≈0
E14/3.5/5-3F45
≈ 5900
≈0
E14/3.5/5-3E6
3F45
780 ±25%
3E6
6400 +40/−30%
2008 Sep 01
E14/3.5/5-3F4-A63-P
4
E14/3.5/5-3F4
Ferroxcube
Planar E cores and accessories
E14/3.5/5
Properties of core sets under power conditions
B (mT) at
GRADE
H = 250 A/m;
f = 10 kHz;
T = 100 °C
CORE LOSS (W) at
f = 100 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 25 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 400 kHz;
ˆ = 50 mT;
B
T = 100 °C
f = 500 kHz;
ˆ = 50 mT;
B
T = 100 °C
E+E14-3C90
≥320
≤ 0.030
−
−
−
−
E+PLT14-3C90
≥320
≤ 0.026
−
−
−
−
E+E14-3C92
≥370
≤ 0.024
−
≤ 0.16
−
−
E+PLT14-3C92
≥370
≤ 0.021
−
≤ 0.15
−
−
E+E14-3C93
≥320
≤ 0.024(1)
−
≤ 0.16 (1)
−
−
E+PLT14-3C93
≥320
≤
−
≤
−
−
0.021(1)
0.15 (1)
E+E14-3C94
≥320
≤ 0.024
−
≤ 0.16
−
−
E+PLT14-3C94
≥320
≤ 0.021
−
≤ 0.15
−
−
E+E14-3C95
≥320
−
≤ 0.17
≤ 0.16
−
−
E+PLT14-3C95
≥320
−
≤ 0.13
≤ 0.12
−
−
E+E14-3C96
≥340
≤ 0.019
−
≤ 0.13
≤ 0.05
≤ 0.11
E+PLT14-3C96
≥340
≤ 0.016
−
≤ 0.12
≤ 0.045
≤ 0.09
E+E14-3F3
≥300
≤ 0.033
−
−
≤ 0.06
−
E+PLT14-3F3
≥300
≤ 0.027
−
−
≤ 0.047
−
E+E14-3F35
≥300
−
−
−
≤ 0.03
≤ 0.05
E+PLT14-3F35
≥300
−
−
−
≤ 0.024
≤ 0.035
1.
Measured at 140 °C.
Properties of core sets under power conditions (continued)
B (mT) at
CORE LOSS (W) at
H = 250 A/m;
f = 10 kHz;
T = 100 °C
f = 500 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 1 MHz;
ˆ = 30 mT;
B
T = 100 °C
f = 1 MHz;
ˆ = 50 mT;
B
T = 100 °C
f = 3 MHz;
ˆ = 10 mT;
B
T = 100 °C
E+E14-3F35
≥300
≤ 0.35
−
−
−
E+PLT14-3F35
≥300
≤ 0.27
−
−
−
E+E14-3F4
≥250
−
≤ 0.09
−
≤ 0.15
E+PLT14-3F4
≥250
−
≤ 0.07
−
≤ 0.12
E+E14-3F45
≥250
−
≤ 0.07
≤ 0.26
≤ 0.12
E+PLT14-3F45
≥250
−
≤ 0.055
≤ 0.2
≤ 0.095
GRADE
2008 Sep 01
5
Ferroxcube
Planar E cores and accessories
E14/3.5/5
MOUNTING INFORMATION
R 0.75 max.
3.2
min.
handbook, 4 columns
5.3 min.
10.6 max.
CBW549
14.5 min.
Fig.3 Recommended PCB cut-out for glued planar E14/3.5/5 cores.
2008 Sep 01
6
Ferroxcube
Planar E cores and accessories
E14/3.5/5
BLISTER TAPE AND REEL DIMENSIONS
K0
handbook, full pagewidth
P0
D0
T
P2
E
F
cover tape
W
B0
MEA613 - 1
A0
D1
P1
direction of unreeling
For dimensions see Table 1.
Fig.4 Blister tape.
Table 1
Physical dimensions of blister tape; see Fig.4
SIZE
DIMENSIONS
(mm)
A0
5.4 ±0.2
B0
14.6 ±0.2
K0
4.0 ±0.2
T
0.3 ±0.05
W
24.0 ±0.3
E
1.75 ±0.1
F
11.5 ±0.1
D0
1.5 +0.1
D1
≥1.5
P0
4.0 ±0.1
P1
8.0 ±0.1
P2
2.0 ±0.1
2008 Sep 01
7
Ferroxcube
Planar E cores and accessories
E14/3.5/5
cover film
direction of
unreeling
blister tape
MEA639
Fig.5 Construction of blister tape.
direction of unreeling
leader 552 mm
minimum number of
empty compartments
trailer
cover tape only
MEA615
Leader: length of leader tape is 552 mm minimum covered with cover tape.
Trailer: 160 mm minimum (secured with tape).
Storage temperature range for tape: −25 to +45 °C.
Fig.6 Leader/trailer tape.
2008 Sep 01
8
Ferroxcube
Planar E cores and accessories
E14/3.5/5
W2
handbook, full pagewidth
20.5
12.75
0.15
N
0
A
MSA284
W1
Dimensions in mm.
For dimensions see Table 2.
Fig.7 Reel.
Table 2
Reel dimensions; see Fig.7
DIMENSIONS (mm)
SIZE
24
2008 Sep 01
A
N
W1
W2
330
100 ±5
24.4
≤28.4
9
Ferroxcube
Planar E cores and accessories
E14/3.5/5
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
10
Similar pages