Vicor MT036A030M040FP Mil-cots mt036 series vtmâ ¢ current multiplier Datasheet

MIL-COTS MT036 SERIES VTM TM Current Multiplier
Features
Size:
1.91 x 1.09 x 0.37 in
48,6 x 27,7 x 9,5 mm
• -55°C to 100°C baseplate operation
• 3 MHz effective switching frequency
• Isolated 1 to 50 Vout
• Low weight – 1.10 oz (31.3 g)
• High density
• 1 µs transient response
• Small footprint
• Up to 96.5% efficiency
• ZVS / ZCS Sine Amplitude Converter
Product Overview
The VI BRICK VTM Current Multiplier
provides extremely fast, efficient, and quiet
fixed ratio voltage division (or current
multiplication). With twelve voltage division
ratios from 1:1 to 1:32, the isolated
VI BRICK VTM provides the user with the
flexibility to supply up to 100 A or 120 W at
any output voltage from 1 to 50 Vdc in a
package occupying ~ 2 square inches.
The Military COTS VI BRICK VTMs are
optimized for use with the Military
Pre-Regulator Module to implement a
Factorized Power Architecture (FPA).
Together, the PRMTM + VTM set provides
the full functionality of a DC-DC converter,
but with breakthrough performance and
flexibility in a rugged, miniature package.
The companion VI BRICK PRM for the MT036
family of VI BRICK VTMs is the 28 Vdc input
MR028A036M012FP, which operates from
an input range of 16-50 Vdc (the data sheet
is available at vicorpower.com). The VTM can
also be used as a standalone POL product.
By factorizing the DC-DC power conversion
into its essential elements – isolation and
transformation on the one hand, and the
output voltage control and regulation on
the other – and arranging those functions
in a sequence that maximizes system
performance, FPA offers a fundamentally
new and significantly improved approach to
power conversion.
The VI BRICK VTM’s fast dynamic response
and low noise eliminate the need for bulk
capacitance at the load, substantially
increasing the POL density while improving
reliability and decreasing cost.
Absolute Maximum Ratings
Parameter
+In to -In
+In to -In
PC to -In
VC to -In
+Out to -Out
Isolation voltage
Output current
Peak output current
Output power
Peak output power
Operating temperature
Storage temperature
Values
-1.0 to 60
100
-0.3 to 7.0
-0.3 to 19.0
Model specific
2,250
Model specific
1.5 • Iout
120
180
-55 to +100
-65 to +125
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
A
A
W
W
°C
°C
Notes
For 100 ms
Input to output
Continuous
For 1 ms
Continuous
For 1 ms
M-Grade; baseplate
M-Grade
Note: Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any other conditions
in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect device reliability.
Voltage Transformation Module
MT036 SERIES
vicorpower.com
Rev. 1.0
Page 1 of 11
SPECIFICATIONS
PART NUMBERING
MT
036
A
120
M
Voltage
Transformation
Module
Input
Voltage
Designator
Package
Size
Output
Voltage
Designator
(=VOUT x10)
010
Operating
M=
P
Baseplate
Pin Style
Output
Current
Designator
(=IOUT)
Product Grade Temperatures (°C)
Grade
F
Storage
F = Slotted flange
T = Transverse heat sink[a]
-55 to +100 -65 to +125
[a] Contact
Input Specifications
P = Through hole
factory
(Conditions are at 36 Vin, full load, and 25°C baseplate unless otherwise specified)
Parameter
Input voltage range
Min
Typ
Max
26
36
Input dV/dt
Input overvoltage turn-on
50.5
Parameter
1.5
Operable down to zero V with VC voltage applied
V/µs
Vdc
57.5
Vdc
3.5
Adc
3.0
6.0
W
Min
Typ
Continuous
Low line to high line
Unit
Note
See Table 1
Vdc
No load
K•VIN – lO•ROUT NOM
Vdc
Full load
100
Adc
26 – 50 VIN See Table 1, Page 5
150%
IMAX(A)
Max pulse width 1ms, max duty cycle 10%,
baseline power 50%
INOM(A)
Module will shut down when current limit
is reached or exceeded
0
Peak repetitive current
DC current limit
Short circuit protection set point
Vdc
1
(Conditions are at 36 Vin, full load, and 25°C baseplate unless otherwise specified)
Output voltage
Rated DC current
50
55.5
Input current
Output Specifications
Notes
54.5
Input overvoltage turn-off
No load power dissipation
Unit
Max
160%
47.4
Current share accuracy
Adc
5
10
%
Efficiency
Module will shut down
See Parallel Operation on Page 8
See Table 2, Page 5
Load capacitance
See Table 2 when used with PRM
Output overvoltage setpoint
110%
115%
VOUT MAX
250
mV
See Figures 2 and 5
20
mV
See Figure 6
3.6
MHz
Model dependent
Output ripple voltage (Typ)
No external bypass
10 µF bypass capacitor
Effective switching frequency
50
2
2.5
3.0
Line regulation
0.99K
K
Load regulation
ROUTMIN
101K
ROUTMAX
VOUT = K•VIN at no load, See Table 1
mΩ
See Table 1
Transient response
Response time
200
ns
See Figures 7 and 8
Recovery time
1
µs
See Figures 7 and 8
Voltage Transformation Module
MT036 SERIES
vicorpower.com
Rev. 1.0
Page 2 of 11
SPECIFICATIONS (CONT.)
TYPICAL WAVEFORMS & PLOTS
Ripple vs. Output Current
Output Ripple (mVpk-pk)
120
100
80
60
40
20
0
0
1
2
3
4
5
6
7
8
9
10
Output Current (A)
Figure 1 — Representative input reflected ripple current at full load
Figure 2 — Sample output voltage ripple vs. output current with no POL
(MT036A120M010FP)
bypass capacitance. (MT036A120M010FP)
Efficiency vs. Output Current
Power Dissipation
96
Power Dissipation (W)
6
Efficiency (%)
94
92
90
88
86
5.5
5
4.5
4
3.5
3
2.5
2
84
0
1
2
3
4
5
6
7
8
9
0
10
1
2
3
4
5
6
7
8
9
10
Output Current (A)
Output Current (A)
Figure 3 — Representative efficiency vs. output current. (MT036A120M010FP)
Figure 4 — Example power dissipation vs. output current. (MT036A120M010FP)
Figure 5 — Sample output voltage ripple at full load; with no POL bypass
Figure 6 — Sample output voltage ripple at full load with 4.7 µF ceramic POL
capacitance. (MT036A120M010FP)
bypass capacitance and 20 nH distribution inductance. (MT036A120M010FP)
Voltage Transformation Module
MT036 SERIES
vicorpower.com
Rev. 1.0
Page 3 of 11
SPECIFICATIONS (CONT.)
TYPICAL WAVEFORMS
Figure 7 — Example load step with 100 µF input capacitance and no output
Figure 8 — Example load step with 100 µF input capacitance and no output
capacitance. (MT036A120M010FP)
capacitance. (MT036A120M010FP)
Voltage Transformation Module
MT036 SERIES
vicorpower.com
Rev. 1.0
Page 4 of 11
SPECIFICATIONS (CONT.)
Military Cots VTM Family Part Numbers and Ranges
K-Factor
Rated Output
Current (A)
MT036A011M100FP
1/32
100
MT036A015M080FP
1/24
MT036A022M055FP
1/16
MT036A030M040FP
1/12
Part Number
No Load Output Voltage (Vdc)
Rout (mΩ)
@26 Vin
@ 50 Vin
Min
Nom
Max
0.82
1.55
0.5
0.85
1.3
80
1.1
2.0
1.0
1.25
1.5
55
1.63
3.1
1.4
1.75
2.0
40
2.2
4.1
1.45
2.4
3.4
MT036A045M027FP
1/8
27
3.3
6.2
3.5
5.1
6.6
MT036A060M020FP
1/6
20
4.3
8.3
5.0
8.0
10
MT036A072M017FP
1/5
16.6
6.4[a]
10
6.0
9.6
12
MT036A090M013FP
1/4
13.3
6.5
12.5
6.9
9.3
11.6
MT036A120M010FP
1/3
10.0
8.7
16.6
25
31
35
MT036A180M007FP
1/2
6.7
13
25
27.5
35.7
46.4
MT036A240M005FP
2/3
5.0
17.4
33
49.3
70.6
91.8
MT036A360M003FP
1
3.3
26
50
140
170
200
Table 1 — VTM part numbers
[a]
Low line input voltage 32 V
Part Number
Typical Full Load Efficiency at nom Vout (%) Typical Half Load Efficiency at nom Vout (%) Maximum Load Capacitance (µF)
MT036A011M100FP
89.5
91.5
48128
MT036A015M080FP
92
94
27072
MT036A022M055FP
94
94.5
12032
MT036A030M040FP
94
95.0
6768
MT036A045M027FP
95.3
96.5
3008
MT036A060M020FP
95.3
96.8
1692
MT036A072M017FP
96.5
96.5
1175
MT036A090M013FP
96.3
95.5
752
MT036A120M010FP
95.5
95.5
423
MT036A180M007FP
96.0
95.2
188
MT036A240M005FP
95.0
94.8
106
MT036A360M003FP
96
96
47
Table 2 — Typical efficiency and maximum load capacitance, by part number
Control Pin Functions
VC – VTM Control
PC – Primary Control
The VC port is multiplexed. It receives the initial VCC voltage from an
upstream PRM, synchronizing the output rise of the VTM with the
output rise of the PRM. Additionally, the VC port provides feedback to
the PRM to compensate for the VTM output resistance. In typical
applications using VTMs powered from PRMs, the PRM’s VC port
should be connected to the VTM VC port.
The Primary Control (PC) port is a multifunction port for controlling the
VTM as follows:
In applications where a VTM is being used without a PRM, 14 V must
be supplied to the VC port for as long as the input voltage is below 26 V
and for 10 ms after the input voltage has reached or exceeded 26 V. The
VTM is not designed for extended operation below 26 V. The VC port
should only be used to provide VCC voltage to the VTM during startup.
Voltage Transformation Module
MT036 SERIES
vicorpower.com
Disable – If PC is left floating, the VTM output is enabled. To
disable the output, the PC port must be pulled lower than 2.4 V,
referenced to -In. Optocouplers, open collector transistors or relays
can be used to control the PC port. Once disabled, 14 V must be
re-applied to the VC port to restart the VTM.
Primary Auxiliary Supply – The PC port can source up to 2.4 mA
at 5 Vdc.
Rev. 1.0
Page 5 of 11
SPECIFICATIONS (CONT.)
General Specifications
Parameter
Min
Typ
Max
Unit
Notes
Hours
25°C, GB
MTBF (MT036A120M010FP)
MIL-HDBK-217F
5,046,701
908,153
50°C NS
711,584
65°C AIC
Isolation specifications
Voltage
2,250
Capacitance
3,000
Resistance
10
Agency approvals
Vdc
Input to output
pF
Input to output
MΩ
Input to output
cTÜVus
UL /CSA 60950-1, EN 60950-1
CE Mark
Low voltage directive
Mechanical
See Mechanical Drawings, Figures 15, 16
Weight
1.10/31.3
oz /g
Length
1.91/48,6
in / mm
Width
1.09/27,7
in / mm
Baseplate model
Height
0.37/9,5
in / mm
Baseplate model
Dimensions
Baseplate model
Thermal
Over temperature shutdown
125
130
135
°C
Thermal capacity
23.8
Ws /°C
Baseplate-to-ambient
7.7
°C / W
Baseplate-to-ambient; 1000 LFM
2.9
°C / W
Baseplate-to-sink; flat, greased surface
0.40
°C / W
Baseplate-to-sink; thermal pad
0.36
°C / W
Junction temperature
Auxiliary Pins
Parameter
Min
Typ
Max
5.2
Unit
Notes
Primary Control (PC)
DC voltage
4.8
5.0
Module disable voltage
2.4
2.5
Module enable voltage
Current limit
2.4
Disable delay time
Vdc
Vdc
VC voltage must be applied when module is
enabled using PC
2.5
2.6
Vdc
2.5
2.9
mA
Source only
µs
PC low to Vout low
10
VTM Control (VC)
External boost voltage
12
External boost duration
Voltage Transformation Module
6
19
10
MT036 SERIES
vicorpower.com
Vdc
Required for VTM start up without PRM
ms
Vin > 26 Vdc. VC must be applied continuously
if Vin < 26 Vdc.
Rev. 1.0
Page 6 of 11
PIN / CONTROL FUNCTIONS
+In / -In DC Voltage Ports
The VTM input should not exceed the maximum specified. Be aware of this
limit in applications where the VTM is being driven above its nominal output voltage. If less than 26 Vdc is present at the +In and -In ports, a continuous VC voltage must be applied for the VTM to process power. Otherwise
VC voltage need only be applied for 10 ms after the voltage at the +In and
-In ports has reached or exceeded 26 Vdc. If the input voltage exceeds the
overvoltage turn-off, the VTM will shutdown. The VTM does not have
internal input reverse polarity protection. Adding a properly sized diode in
series with the positive input or a fused reverse-shunt diode will provide
reverse polarity protection.
TM – For Factory Use Only
VC – VTM Control
The VC port is multiplexed. It receives the initial VCC voltage from an
upstream PRM, synchronizing the output rise of the VTM with the output
rise of the PRM. Additionally, the VC port provides feedback to the PRM to
compensate for the VTM output resistance. In typical applications using
VTMs powered from PRMs, the PRM’s VC port should be connected to the
VTM VC port.
Figure 9 — VI BRICK VTM pin configuration (viewed from pin side)
In applications where a VTM is being used without a PRM, 14 V must be
supplied to the VC port for as long as the input voltage is below 26 V and
for 10 ms after the input voltage has reached or exceeded 26 V. The VTM is
not designed for extended operation below 26 V. The VC port should only be
used to provide VCC voltage to the VTM during startup.
PC – Primary Control
The Primary Control (PC) port is a multifunction port for controlling the
VTM as follows:
Disable – If PC is left floating, the VTM output is enabled. To
disable the output, the PC port must be pulled lower than 2.4 V,
referenced to -In. Optocouplers, open collector transistors or relays
can be used to control the PC port. Once disabled, 14 V must be
re-applied to the VC port to restart the VTM.
Primary Auxiliary Supply – The PC port can source up to 2.4 mA
at 5 Vdc.
+Out / -Out DC Voltage Output Ports
The output and output return are through two sets of contact locations.
The respective +Out and –Out groups must be connected in parallel with
as low an interconnect resistance as possible.
To take full advantage of the VTM, the user should note the low output
impedance of the device. The low output impedance provides fast transient response without the need for bulk POL capacitance. Limited-life
electrolytic capacitors required with conventional converters can be
reduced or even eliminated, saving cost and valuable board real estate.
Voltage Transformation Module
MT036 SERIES
vicorpower.com
Rev. 1.0
Page 7 of 11
APPLICATION NOTES & TEST CIRCUIT
Parallel Operation
In applications requiring higher current or redundancy, VTMs can be
operated in parallel without adding control circuitry or signal lines. To
maximize current sharing accuracy, it is imperative that the source and
load impedance on each VTM in a parallel array be equal. If VTMs are
being fed by an upstream PRM, the VC nodes of all VTMs must be
connected to the PRM VC.
To achieve matched impedances, dedicated power planes within the PC
board should be used for the output and output return paths to the
array of paralleled VTMs. This technique is preferable to using traces of
varying size and length.
The VTM power train and control architecture allow bi-directional power
transfer when the VTM is operating within its specified ranges. Bi-directional power processing improves transient response in the event of an
output load dump. The VTM may operate in reverse, returning output
power back to the input source. It does so efficiently.
Anomalies in the response of the source will appear at the output of the
VTM, multiplied by its K factor of 1/8 . The DC resistance of the source
should be kept as low as possible to minimize voltage deviations on the
input to the VTM. If the VTM is going to be operating close to the high
limit of its input range, make sure input voltage deviations will not
trigger the input overvoltage turn-off threshold.
Input Fuse Recommendations
VI BRICKs are not internally fused in order to provide flexibility in
configuring power systems. However, input line fusing of VI BRICKs must
always be incorporated within the power system. A fast acting fuse is
required to meet safety agency Conditions of Acceptability. The input
line fuse should be placed in series with the +In port. For agency
approvals and fusing conditions, click on the link below:
http://www.vicorpower.com/technical_library/technical_documentation/quality_
and_certification/safety_approvals/
Input Impedance Recommendations
To take full advantage of the VTM’s capabilities, the impedance of the
source (input source plus the PC board impedance) must be low over a
range from DC to 5 MHz. The input of the VTM (factorized bus) should
be locally bypassed with a 8 µF low Q aluminum electrolytic capacitor.
Additional input capacitance may be added to improve transient
performance or compensate for high source impedance. The VTM has
extremely wide bandwidth so the source response to transients is usually
the limiting factor in overall output response of the VTM.
Application Notes
For VTM and VI BRICK application notes on soldering, thermal
management, board layout, and system design click on the link below:
http://www.vicorpower.com/technical_library/application_information/
Input reflected ripple
measurement point
7 A[a]
Fuse
F1
C1
47 µF
Al electrolytic
+IN
C2
0.47 μF
ceramic
TM
VC
PC
14 V +
–
-IN
+
+OUT
-OUT
R3
10 mΩ
+OUT
C3
10 µF
VTM
Load
-OUT
–
Notes:
1. C3 should be placed close to the load
2. R3 may be ESR of C3 or a separate damping resistor.
[a]
See Input Fuse Recommendations section
Figure 10 — VI BRICK VTM test circuit
Voltage Transformation Module
MT036 SERIES
vicorpower.com
Rev. 1.0
Page 8 of 11
APPLICATION NOTES (CONT.)
In figures below;
K = VTM transformation ratio
RO = VTM output resistance
Vf = PRM output (Factorized Bus Voltage)
VO = VTM output
VL = Desired load voltage
FPA ADAPTIVE LOOP
Vo = VL ± 1.0%
VC
PC
TM
IL
NC
PR
+IN
PRM-AL
VH
SC
SG
OS
NC
CD
ROS
RCD
+OUT
Vin
-IN
Factorized
Bus (Vf)
-OUT
VL (Io•Ro)
Vf =
+
K
K
+IN
+OUT
-OUT
TM
VC
PC
-IN
VTM
+OUT
-OUT
L
O
A
D
Figure 11 — The PRM controls the factorized bus voltage, Vf, in proportion to output current to compensate for the output resistance, Ro, of the VTM. The VTM
output voltage is typically within 1% of the desired load voltage (VL) over all line and load conditions.
Voltage Transformation Module
MT036 SERIES
vicorpower.com
Rev. 1.0
Page 9 of 11
MECHANICAL DRAWINGS
Baseplate - Slotted Flange
Heat Sink (Transverse)
Figure 15 — Module outline
Recommended PCB Pattern
(Component side shown)
Figure 16 — PCB mounting specifications
Voltage Transformation Module
MT036 SERIES
vicorpower.com
Rev. 1.0
Page 10 of 11
Warranty
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in
normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application
or maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original
purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING,
BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty,
the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products
returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning
the product to the factory. Vicor will pay all reshipment charges if the product was defective within the terms of this
warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is
assumed for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve
reliability, function, or design. Vicor does not assume any liability arising out of the application or use of any product or
circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not
recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten
life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes
all risks of such use and indemnifies Vicor against all damages.
Vicor’s comprehensive line of power solutions includes high density AC-DC and
DC-DC modules and accessory components, fully configurable AC-DC and DC-DC
power supplies, and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for
its use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or
malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available
upon request.
Specifications are subject to change without notice.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent
applications) relating to the products described in this data sheet. Interested parties should contact Vicor's Intellectual Property Department.
The products described on this data sheet are protected by the following U.S. Patents Numbers:
5,945,130; 6,403,009; 6,710,257; 6,911,848; 6,930,893; 6,934,166; 6,940,013; 6,969,909; 7,038,917;
7,145,186; 7,166,898; 7,187,263; 7,202,646; 7,361,844; D496,906; D505,114; D506,438; D509,472; and for
use under U.S. Pat. Nos. 6,975,098 and 6,984,965.