MPD MPA320X-15Z Smallest 1u 320w single output power factor corrected ac/dc power supply Datasheet

MPA320 Series
Smallest 1U 320W
Single Output
Power Factor Corrected
AC/DC Power Supplies
Key Features:
• Smallest 1U 320W Supply
• PFC to EN61000-3-2 “A”
• UL, cUL, TUV Approvals
• CE Certified
• FCC Class B Emissions
• 2 - 60 V Output Voltages
• Auto Selectable AC Input
• 700W Peak Power
• Four Mechanical Options
Only
6 x 4 x 1.5
Inches!!
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without
h
notice.
notic
Input
Parameter
Input Voltage Range
Conditions
Autoranging
Input Frequency
Input Current, Full Load
Inrush Current, Cold Start
Leakage Current (Note 1)
Power Factor Correction
Input Protection
Min.
90
180
47
Typ.
100 - 120 VAC
8
200 - 240 VAC
4
110 VAC
220 VAC
240 VAC
1.5
Meets EN61000-3-2 Class A
T8A/250V Fuse
Max.
132
264
63
Units
VAC
Hz
A
35
70
A
mA
Output
Parameter
Output Voltage Adjustment
Output Regulation (Note 2)
Hold Time
Ripple & Noise (20 MHz) (Note 3)
Overload Protection
Over Voltage Protection
Over Temperature Protection
Temperature Coefficient
Transient Recovery Time (Note 4)
Transient Response Deviation
Overshoot/Undershoot
Turn On Delay
Output Short Circuit
Conditions
Min.
Typ.
Max.
±5.0
±1.0
110 VAC, 80% Load
20
See Model Selection Guide
Power Limit
130
160
>130% of Rated Output Voltage. Recycle AC Input.
By Trim Pot
±0.04
2.5
5
50% Load Change
At Turn On/Off
120 VAC
Continuous With Autorecovery
Units
%
%
mSec
%
5.0
1
%/ºC
mS
%
%
S
Max.
Units
General
Parameter
Isolation Voltage (Note 5)
Switching Frequency
MicroPower Direct Interface Signals
292 Page Street
Suite D
Stoughton, MA 02072
USA
Power Supply On
Power Good Signal
Fan Fail
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Conditions
Input - Output
Input - FG (Frame Ground)
Primary - Core
Fixed
Min.
3,000
1,500
1,500
Typ.
VAC
23
kHz
Green LED (LED1) on the PCB
PG on CN1. Goes TTL high 100 to 500 mS after regulation. Goes low at
least 1 mS before the loss of regulation. Will sink 100 mA.
FF on pin 3 of CN1. Open collector output rated for 15 VDC/5 mA sink
current maximum. Goes high if a fan failure is detected
Environmental
Parameter
Operating Temperature Range
Output Derating
Storage Temperature Range
Cooling
Operating Humidity
Conditions
Min.
Typ.
Max.
Ambient
0
+25
+50
2.5%/ ºC from +50 ºC to + 70 ºC
-20
+85
See Model Selection Guide
RH, Non-condensing
90
Units
ºC
ºC
%
Reliability Specifications
Parameter
MTBF
Safety Standards
EEMI Compliance
EMS Immunity Compliance
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 30ºC, Gnd Benign
100
kHours
UL 60950; CSA C22.2 No. 60950; TUV EN60950; CB Report (IEC 60950)
Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3
EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD)
Model Selection Guide
Model
Number
MPA320x-05z
MPA320x-09z
MPA320x-12z
MPA320x-15z
MPA320x-18z
MPA320x-24z
MPA320x-28z
MPA320x-36z
MPA320x-48z
MPA320x-54z
Output Voltage
Factory
Range
PreSet
5 VDC
2.0 - 5.5 VDC
9 VDC
6.0 - 11.0 VDC
12 VDC 12.0 - 13.5 VDC
15 VDC 13.6 - 15.0 VDC
18 VDC 16.0 - 20.0 VDC
24 VDC 21.0 - 26.0 VDC
28 VDC 27.0 - 34.0 VDC
36 VDC 35.0 - 42.0 VDC
48 VDC 43.0 - 50.0 VDC
54 VDC 51.0 - 60.0 VDC
Max. Output Current (Notes 7, 8)
Ripple &
“U, E, F” Units “U” Units
“C” Units
Noise
22 CFM
Convection Convection
45.00A
27.28A
25.00A
50 mV p-p
29.10A
16.37A
13.64A
1% p-p
26.66A
15.00A
14.16A
1% p-p
21.33A
12.00A
11.33A
1% p-p
17.77A
10.00A
9.44A
1% p-p
13.33A
7.50A
7.08A
1% p-p
11.42A
6.42A
6.07A
1% p-p
8.88A
5.00A
4.72A
1% p-p
6.66A
3.75A
3.54A
1% p-p
5.92A
3.33A
3.14A
1% p-p
Notes:
1. Models are available with leakage current specified as low as 500 μA
(at 240 VAC) / 300 μA (at 120 VAC). Contact the factory for details.
2. Output regulation includes line & load.
3. Ripple & noise is measured from 10 Hz to 20 MHz. Measurement
connection to the unit is made with a 0.1 μF ceramic capacitor & a 22
μF electrolytic capacitor connected in parallel.
4. Transient recovery is measured to within a 1% error band for a load
step change of 50% to 100%.
5. Isolation specifications are production HI-Pot tested for 3 seconds.
Efficiency
(Note 7)
Input & Output Connector CN2:
Howder Terminal Block No. HB-95-7P or
Mating Molex Part No. 09-91-1600 (16 pin)
Output Pin Assignment:
75%
80%
83%
83%
83%
83%
83%
83%
83%
83%
6. The full output range (see table above) is covered in the safety agency certification. Standard models are factory set to the “Preset” voltage. This may be set to other levels within
the range without affecting the agency certification. Contact the factory for details.
7. Output current is given for the factory preset voltage. With the exception of the “05”
output model, the maximum continuous output power level is 320W (with 22 CFM),
180W (U-Chassis convection cooled) or 170W (“C” units convection cooled. For more
information, contact the factory.
8. Units will provide peak power of 700W for 500 μS. For units capable of longer durations,
contact the factory.
9. A 1% minimum load is required to maintain regulation and ripple specifications.
Howder
Molex
Pins 1 ~ 2: V+
Pins 1 ~ 5: V+
Pins 3 ~ 4: V-
Pins 6 ~ 10: V-
Pin 5: Grnd
Pin 12: Grnd
Pin 6: Neutral
Pin 14: Neutral
Pin 7: Line
Pin 16: Line
Logic Signal Connector CN1:
Mating JST XHP or equivalent (CHYAO
SHIUNN JS-21001-3) Mating Pins: JST
SXH-002T-P0.6 for AWG 30 to 26.
Fan driver connector (FAN2):
12 VDC / 400 mA is available to drive an
external fan. Mating connector is a JST
XHP-2 or Molex P/N 48-151-0210 ( 2 pins
0.98 pitch). Mating Pins: JST SXH-001TP0.62T or Molex 48150 .
Mechanical Dimensions: U-Chassis (U Suffix)
U-Chassis Cover (C Suffix)
Enclosure With End Fan (E Suffix)
Enclosure With Top Fan (F Suffix)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]