DYELEC MBR2090CTD 20 amperes schottky barrier rectifier Datasheet

MBR2040CTD~MBR20200CTD
20 AMPERES SCHOTTKY BARRIER RECTIFIERS
VOLTAGE
40 to 200 Volts
CURRENT
20 Amperes
FEATURES
TO-220AB
• Plastic package has Underwriters Laboratory
Flammability Classification 94V-0.
Flame Retardant Epoxy Molding Compound.
• Metal silicon junction, majority carrier conduction
• Low power loss, high efficiency.
• High current capability
• For use in low voltage, high frequency inverters
free wheeling, and polarlity protection applications.
• Lead free in comply with EU RoHS
MECHANICAL DATA
• Case: TO-220AB molded plastic
• Terminals: Solder plated, solderable per MIL-STD-750, Method 2026
• Polarity: As marked.
• Mounting Position: Any
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
PARAMETER
Maximum Recurrent P e a k
Reverse V o l t a g
S YMB OL
V
RRM
Maximum RMS Voltage
V
Maximum DC B locking Voltage
V
Maximum Average Forward Current (See fi g.1 )
I
Peak Forward Surge Current :8 .3 ms s i ngle half s i
ne- wa ve superimposed on rated l oad(JED EC
t h d)
Maximum Forward Voltage at 10 A, per leg
I
RMS
DC
MBR
2040CTD
MBR
2045CTD
MBR
2050CTD
MBR
2060CTD
MBR
2080CTD
UNITS
60
80
90
100
150
200
V
28
31.5
35
42
56
63
70
105
140
V
40
45
50
60
80
90
100
150
200
V
FSM
0 .7
20
A
150A
A
0.85
0.8
0.05
20
Typical Thermal Resistance
R
2
Apr,2015-REV.02
MBR
20200CTD
50
IR
0.92
V
mA
O
θJ C
T ,T
J
MBR
20150CTD
45
Maximum DC Reverse Current TJ =25 OC
at Rated DC B locking Voltage TJ=125 OC
Operating Junction and Storage Temperature Range
MBR
20100CTD
40
F ( A V)
VF
MBR
2090CTD
S TG
-50 to + 150
www.dyelec.com
-55 to +175
C/
W
O
C
PAGE . 1
MBR2040CTD~MBR20200CTD
20.0
= 40 - 100V
=150 - 200V
16.0
12.0
8.0
RESISTIVE OR
INDUCTIVE LOAD
4.0
0
0
20
40
60
80
100
120
140
160
180
PEAK FORWARD SURGE CURRENT,
Amps
AVERAGE FORWARD RECTIFIED
CURRENT AMPERES
RATING AND CHARACTERISTIC CURVES
LEAD TEMPERATURE, C
O
240
210
8.3m s S i n g l e
Half Since-Wave
JEDEC M e th o d
180
150
120
90
60
30
0
1
2
5
10
20
50
100
NO. OF CYCLE AT 60Hz
Fig.1- FORWARD CURRENT DERATING CURVE
Fig.2- MAXIMUM NON - REPETITIVE SURGE
CURRENT
40
40-45V
FORWARD CURRENT, Amps
INSTANTANEOUS REVERSE CURRENT, mA
10
O
T J =100 C
1.0
T J = 75 O C
0.1
T J = 25 C
O
0.01
0.001
50-60V
80-100V
2
20
40
60
80
100 120
140
150-200V
1.0
0.8
0.6
0.4
TJ = 25OC
Pulse Width = 300 us
1% Duty Cycle
0.2
0.1
0
0.4
0.5
0.6
0.7
0.8 0.9
1.0
1.1
FORWARD VOLTAGE, VOLTS
PERCENT OF INSTANTANEOUS REVERSE VOLTAGE,(%)
Fig.3- TYPICAL REVERSE CHARACTERISTICS
Apr,2015-REV.02
10
8
6
4
www.dyelec.com
Fig.4- TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
PAGE . 2
MBR2040CTD~MBR20200CTD
Important Notice and Disclaimer
•Reproducing and modifying information of the document is prohibited without permission
from DIYI.
•DIYI reserves the right to make changes to this document and its products and
specifications at any time without notice. Customers should obtain and confirm the
latest product information and specifications before final design, purchase or use.
•DIYI disclaims any and all liability arising out of the application or use of
any product including damages incidentally and consequentially occurred.
•DIYI does not assume any and all implied warranties, including warranties of fitness for
particular purpose, non-infringement and merchantability.
•Applications shown on the herein document are examples of standard use and
operation. Customers are responsible in comprehending the suitable use in particular
applications.
DIYI makes no representation or warranty that such applications will be suitable for the
specified use without further testing or modification.
•The products shown herein are not designed and authorized for equipments requiring high
level of reliability or relating to human life and for any applications concerning life-saving
or life-sustaining, such as medical instruments, transportation equipment, aerospace
machinery et cetera. Customers using or selling these products for use in such applications
do so at their own risk and agree to fully indemnify DIYI for any damages resulting from such
improper use or sale.
•Since DIYI uses lot number as the tracking base, please provide the lot number for tracking
when complaining.
Apr,2015-REV.02
www.dyelec.com
PAGE . 3