MORNSUN B2412S-2W Dual/single output dc-dc converter Datasheet

A_S-2W & B_S-2W Series
2W, FIXED INPUT, ISOLATED & UNREGULATED
DUAL/SINGLE OUTPUT DC-DC CONVERTER
RoHS
FEATURES
PRODUCT PROGRAM
High Efficiency up to 86%
1KVDC Isolation
SIP Package
Internal SMD Construction
Temperature Range: -40°C to +85°C
No Heat sink Required
No External Component Required
Industry Standard Pinout
RoHS Compliance
Input
Part
Number
Output
Voltage (VDC)
Nominal
Range
Voltage
(VDC)
3.3
2.97-3.63
B0303S-2W
Efficiency
(%, Typ)
Current (mA)
Max
UL CE
Min
3.3
400
40
73
A0505S-2W
±5
±200
±20
82
A0509S-2W
±9
±111
±12
85
UL
A0512S-2W
±12
±83
±9
86
UL
A0515S-2W
±15
±67
±7
82
UL
A0524S-2W
±24
±42
±5
82
B0503S-2W
5
4.5-5.5
UL
3.3
400
40
74
B0505S-2W
5
400
40
81
UL CE
B0509S-2W
9
222
23
84
UL CE
Series are
B0512S-2W
12
167
17
83
UL CE
specially designed for applications where a
B0515S-2W
15
133
14
84
UL CE
group of polar power supplies are isolated
A1205S-2W
±5
±200
±20
81
UL
from the input power supply in a distributed
A1209S-2W
±9
±111
±12
84
UL
power supply system on a circuit board.
A1212S-2W
±12
±83
±9
86
UL
These products apply to:
A1215S-2W
±15
±67
±7
82
UL
1) Where the voltage of the input power
B1205S-2W
5
400
40
81
UL CE
supply is fixed (voltage variation ≤
B1209S-2W
9
222
23
82
UL CE
±10%);
B1212S-2W
12
167
17
85
UL CE
B1215S-2W
15
133
14
82
UL CE
A1505S-2W
±5
±200
±20
80
APPLICATIONS
The A_S-2W & B_S-2W
2) Where isolation is necessary between
input
and
output
(isolation
voltage
≤1000VDC);
voltage and the output ripple noise are
not demanding.
Such as: purely digital circuits, ordinary low
frequency analog circuits, and IGBT power
device driving circuits.
15
10.8-13.2
13.5-16.5
±5
400
40
80
A2405S-2W
±5
±200
±20
80
A2409S-2W
±9
±111
±12
84
UL
A2412S-2W
±12
±83
±9
84
UL
A2415S-2W
±15
±67
±7
84
UL
A2424S-2W
±24
±42
±5
85
B1505S-2W
3) Where the regulation of the output
12
B2405S-2W
24
21.6-26.4
UL
5
400
40
80
UL CE
B2409S-2W
9
222
23
83
UL CE
B2412S-2W
12
167
17
84
UL CE
MODEL SELECTION
B2415S-2W
15
133
14
84
UL CE
A0505S-2W
B2424S-2W
24
84
10
84
Note: The A_S-1W/B_LS-1W series also are available in our company.
Rated Power
Package Styl e
Ou tp ut Vol tage
Inp ut Volta ge
Pro duc t Se ries
COMMON SPECIFICATIONS
Item
Test conditions
Min
Typ
-40
85
Storage Temp. Range
-55
125
Storage humidity range
Address: 2th floor 6th building, Hangzhou
Industrial District, Guangzhou, China
Tel: 86-20-38601850
Fax: 86-20-38601272
http://www.mornsun-power.com
°C
%
Free air convection
Temp. rise at full load
Lead temperature
Units
95
Cooling
MORNSUN Science& Technology co.,Ltd.
Max
Operating Temp. Range
15
1.5mm from case for 10 seconds
25
°C
300
Short circuit protection*
1
Case material
s
Plastic (UL94-V0)
MTBF
3500
Weight
K hours
2.8
g
*Supply voltage must be discontinued at the end of short circuit duration.
MORNSUN reserves the copyright
Specifications subject to change without notice.
A_S-2W & B_S-2W
A/1-2008
Page 1 of 2
ISOLATION SPECIFICATIONS
Item
Test conditions
Min
Isolation voltage
Tested for 1 minute and 1 mA max
1000
VDC
1000
MΩ
Isolation resistance Test at 500VDC
Typ
Max
Units
OUTPUT SPECIFICATIONS
Item
Test conditions
Min
Output power
Line regulation
Load regulation
Typ
Max
Units
2
W
0.2
10% to 100% load
(5V output)
12.8
15
(9V output)
8.3
15
(12V output)
6.8
15
(15V output)
6.3
15
(24V output)
5
15
Output voltage accuracy
100% full load
Ripple & Noise*
20MHz Bandwidth
%
Switching frequency Full load, nominal input
filtering
network
Dual Output
may
be
L
L
+Vo
Cout
DC DC
Cin
150
mVp-p
KHz
-Vo
Single Output
TYPICAL CHARACTERISTICS
L
L
+Vo
Vin
Cout
DC DC
Cin
GND
0V
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power
Converter section, application notes.
Note:
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load
unless otherwise specified.
2. Dual output models unbalanced load: ±5%.
0V
L Cout
GND
%/°C
75
“LC”
an
Vin
0.03
75
ripple,
DC/DC converter, see (Figure 1).
See tolerance envelope graph
Temperature drift
Recommended testing and application circuit
If you want to further decrease the input/output
connected to the input and output ends of the
±1.2
For Vin change of 1%
Overload Protection
Under normal operating conditions, the output
circuit of these products has no protection
against overload. The simplest method is to
connect a self-recovery fuse in series at the
input end or add a circuit breaker to the circuit.
(Figure 1)
It should also be noted that the inductance and
the frequency of the “LC” filtering network should
be staggered with the DC/DC frequency to avoid
mutual interference. However, the capacitance of
the output filter capacitor must be proper. If the
capacitance is too big, a startup problem might
arise. For every channel of output, provided the
safe and reliable operation is ensured, the
greatest capacitance of its filter capacitor sees
(Table 1).
EXTERNAL CAPACITOR TABLE (TABLE 1)
Ambient Temperature ( C )
OUTLINE DIMENSIONS & PIN CONNECTIONS
RECOMMENDED FOOTPRINT
Top view,grid:2.54*2.54mm(0.1*0.1inch)
diameter:1.00mm(0.039inch)
(0.276)
(0.035)
First Angle Projection
Vin
(VDC)
Cin
(uF)
5
4.7
Single
Vout
(VDC)
5
Cout
(uF)
10
Dual
Vout
(VDC)
±5
Cout
(uF)
12
2.2
9
4.7
±9
15
2.2
12
2.2
±12
2.2
1
24
1
15
1
±15
0.47
4.7
It’s not recommended to connect any external
Dual Output
capacitor in the application field with less than 0.5
(0.079)
1 2
(0.100)
watt output.
4 5 6
Output Voltage Regulation and Over-voltage
Protection Circuit
The simplest device for output voltage
1 2
4.10
(0.374)
Single Output
4
regulation,
6
over-voltage
and
over-current
protection is a linear voltage regulator with
overheat protection that is connected to the input
FOOTPRINT DETAILS
(0.020)
Pin
Note:
Unit:mm(inch)
Pin section:0.50*0.30mm(0.020*0.012inch)
Pin tolerances: 0.10mm( 0.004inch)
General tolerances: 0.25mm( 0.010inch)
Singles
or output end in series (Figure 2).
Duals
1
Vin
Vin
2
GND
GND
4
0V
-V0
5
No Pin
0V
6
+Vo
Dual O u tput
Vi n
R EG
REG
+Vout
REG
-Vout
REG
+Vout
0V
DC DC
GND
+Vo
S ingle Output
APPLICATION NOTE
Vi n
Requirement on output load
To ensure this module can operate efficiently and reliably, During operation, the minimum
R EG
GND
output load is not less than 10% of the full load, and that this product should never be
DC DC
0V
(Figure 2)
operated under no load! If the actual output power is very small, please connect a resistor
with proper resistance at the output end in parallel to increase the load, or use our company’s
No parallel connection or plug and play.
products with a lower rated output power (A_S-1W /B_LS-1W Series).
MORNSUN reserves the copyright
Specifications subject to change without notice.
A_S-2W & B_S-2W
A/1-2008
Page 2 of 2
Similar pages