CUI CFM-4010V-185-314 Dc axial fan Datasheet

For more information, please visit the product page.
date
07/21/2017
page
1 of 11
SERIES: CFM-40V │ DESCRIPTION: DC AXIAL FAN
FEATURES
•
•
•
•
•
omniCOOLTM bearing system
40 x 40 mm frame
multiple speed options for different cooling needs
tachometer signal and rotation detect options available
auto restart protection standard on all models
MODEL
input
voltage
CFM-4010V-058-206
input
current1
input
power1
rated
speed1
air
flow2
static
pressure3
noise4
rated
(Vdc)
range
(Vdc)
max
(mA)
max
(W)
typ
(RPM±15%)
(CFM)
(inch H2O)
max
(dBA)
5
3.5~6
109
0.55
5800
7.0
0.12
20.6
CFM-4010V-070-273
5
3.5~6
157
0.79
7000
8.0
0.19
27.3
CFM-4010V-150-157
12
4.5~13.8
38
0.46
5000
5.4
0.09
15.7
CFM-4010V-158-206
12
6~13.8
48
0.58
5800
7.0
0.12
20.6
CFM-4010V-170-273
12
4.5~13.8
59
0.71
7000
8.0
0.19
27.3
CFM-4010V-185-314
12
4.5~13.8
101
1.22
8500
9.9
0.25
31.4
CFM-4020V-050-165
5
3.5~6
87
0.44
5000
6.3
0.11
16.5
CFM-4020V-060-210
5
3.5~6
124
0.62
6000
7.7
0.17
21.0
CFM-4020V-070-255
5
3.5~6
173
0.87
7000
8.9
0.22
25.5
CFM-4020V-145-123
12
4.5~13.8
38
0.46
4500
5.5
0.10
12.3
CFM-4020V-150-165
12
4.5~13.8
46
0.56
5000
6.3
0.11
16.5
CFM-4020V-160-210
12
4.5~13.8
54
0.65
6000
7.7
0.17
21.0
CFM-4020V-170-255
12
4.5~13.8
67
0.81
7000
8.9
0.22
25.5
CFM-4020V-180-275
12
4.5~13.8
92
1.11
8000
10.8
0.29
27.5
CFM-4020V-260-210
24
8~27.6
30
0.72
6000
7.7
0.17
21.0
CFM-4020V-270-255
24
8~27.6
39
0.94
7000
8.9
0.22
25.5
CFM-4020V-280-275
24
8~27.6
45
1.08
8000
10.8
0.29
27.5
Notes:
1.
2.
3.
4.
5.
At rated voltage, 25°C, 0 inch H20 static pressure, after 10 minutes
As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H20 static pressure
As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow.
Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake.
All specifications are measured at 25°C, 65% relative humidity unless otherwise specified.
PART NUMBER KEY
CFM-4010V-058-206 - XX - CXX
Base Number
Fan Signals
“blank” = no signals
11 = rotation detector signal
20 = tachometer signal
cui.com
Reserved for Custom
Configurations
For more information, please visit the product page.
CUI Inc │ SERIES: CFM-40V │ DESCRIPTION: DC AXIAL FAN
date 07/21/2017 │ page 2 of 11
INPUT
parameter
conditions/description
min
typ
max
units
operating input voltage1
5 Vdc input models
12 Vdc input models
24 Vdc input models
3.5
4.5
8
5
12
24
6
13.8
27.6
Vdc
Vdc
Vdc
starting voltage2
5 Vdc input models
12 Vdc input models
24 Vdc input models
Note:
3.5
4.5
8
Vdc
Vdc
Vdc
1. See Model section on page 1 for specific input voltage ranges.
2. Starting voltage for model CFM-4010V-158-206 is 6 Vdc.
PERFORMANCE3
parameter
conditions/description
min
rated speed
at rated voltage, 25°C, after 10 minutes
air flow
at 0 inch H2O, see performance curves
static pressure
noise
Note:
typ
max
units
4500
8500
RPM
5.4
10.8
CFM
at 0 CFM, see performance curves
0.09
0.29
inch H2O
at 1 m
12.3
31.4
dBA
3. See Model section on page 1 for specific values.
PROTECTIONS / FEATURES4
parameter
conditions/description
auto restart
on all models
rotation detector signal
available on “11” models
tachometer signal
available on “20” models
Notes:
min
typ
max
units
min
typ
max
units
4. See Application Notes for details.
SAFETY & COMPLIANCE
parameter
conditions/description
insulation resistance of frame
at 500 Vdc between internal stator and positive
lead wire
dielectric strength
apply 500 Vac for 1 minute between housing and
positive lead wire
safety approvals
UL/cUL 507, TUV (EN 60950-1)
EMI/EMC
EN 61000-6-1:2007, EN 61000-6-3:2007+A1
life expectancy
at 40°C, 65% RH
RoHS
2011/65/EU
10
MΩ
70,000
hours
ENVIRONMENTAL
parameter
max
units
operating temperature
conditions/description
min
-10
70
°C
storage temperature
-40
70
°C
cui.com
typ
For more information, please visit the product page.
CUI Inc │ SERIES: CFM-40V │ DESCRIPTION: DC AXIAL FAN
date 07/21/2017 │ page 3 of 11
PERFORMANCE CURVES
CFM-4010V-058-206
CFM-4010V-070-273
0.11
Air Flow (CMM)
0.165
0.22
0.12
3
0.08
2
0.06
1.5
0.04
1
0.02
0.5
0
0
2
4
Air Flow (CFM)
6
8
0.2
0.22
5
0.16
4
0.12
3
0.08
2
0.04
1
0
0
2
0.165
0.22
Air Flow (CFM)
0
0.04
1
0.02
0.5
3
4
Air Flow (CFM)
5
6
0.055
0.11
3
0.1
2.5
2
1.5
Static Pressure (inch H O)
0.06
2
8
0.12
Static Pressure (mm H O)
2
2
Static Pressure (inch H O)
0
0.168
0.08
1
6
Air Flow (CMM)
0.14
2.5
0
4
2
0.028 0.056 0.084 0.112
0.1
0
0.165
CFM-4010V-158-206
Air Flow (CMM)
0
0.11
2
0
CFM-4010V-150-157
0.055
2
Static Pressure (inch H O)
2
2
2.5
Static Pressure (mm H O)
0.1
Static Pressure (inch H O)
0
0.08
2
0.06
1.5
0.04
1
0.02
0.5
0
0
cui.com
Static Pressure (mm H O)
0.055
Static Pressure (mm H O)
Air Flow (CMM)
0
0
2
4
Air Flow (CFM)
6
8
0
For more information, please visit the product page.
CUI Inc │ SERIES: CFM-40V │ DESCRIPTION: DC AXIAL FAN
date 07/21/2017 │ page 4 of 11
PERFORMANCE CURVES (CONTINUED)
CFM-4010V-185-314
Air Flow (CMM)
0.28
6.35
0.16
4
0.2
5.08
0.12
3
0.15
3.81
0.08
2
0.1
2.54
0.04
1
0.05
1.27
2
4
6
Air Flow (CFM)
8
0
0
CFM-4020V-050-165
0
2
4
0.11
0
2
0.08
2
0.06
1.5
0.04
1
0.02
0.5
4
Air Flow (CFM)
6
8
0.055
0.11
0.165
0.22
0.2
5
0.16
4
0.12
3
0.08
2
0.04
1
2
Static Pressure (inch H O)
Static Pressure (mm H O)
2
Static Pressure (inch H O)
0
0.22
3
2.5
2
10
Air Flow (CMM)
0.165
0.1
0
8
CFM-4020V-060-210
0.12
0
6
0
2
0.055
0.224
Air Flow (CFM)
Air Flow (CMM)
0
0.168
0
cui.com
Static Pressure (mm H O)
0
0.112
2
2
0
0.056
2
Static Pressure (mm H O)
0.165
2
Static Pressure (inch H O)
0.11
Static Pressure (inch H O)
0.2
0.25
0.055
0
Air Flow (CMM)
0.22
5
0
Static Pressure (mm H O)
CFM-4010V-170-273
0
2
4
Air Flow (CFM)
6
8
0
For more information, please visit the product page.
CUI Inc │ SERIES: CFM-40V │ DESCRIPTION: DC AXIAL FAN
date 07/21/2017 │ page 5 of 11
PERFORMANCE CURVES (CONTINUED)
CFM-4020V-070-255
6
0.18
4.5
3
0.12
1.5
0.06
4
6
Air Flow (CFM)
8
10
2.5
2
0.06
1.5
0.04
1
0.02
0.5
0
0
1
2
0.08
0.12
0.2
0
Static Pressure (inch H O)
6
0
2
0.08
2
0.06
1.5
0.04
1
0.02
0.5
2.8
4.2
Air Flow (CFM)
5.6
7
0.055
0.11
0.165
0.22
0.2
5
0.16
4
0.12
3
0.08
2
0.04
1
2
Static Pressure (mm H O)
2.5
2
Static Pressure (inch H O)
0.1
1.4
5
Air Flow (CMM)
0.16
3
0
4
CFM-4020V-160-210
0.12
0
3
Air Flow (CFM)
Air Flow (CMM)
0.04
0.168
0.08
0
CFM-4020V-160-165
0
0.14
0.1
0
0
cui.com
0
2
4
Air Flow (CFM)
6
8
0
2
2
0.028 0.056 0.084 0.112
Static Pressure (mm H O)
0
0
2
0.24
0
Air Flow (CMM)
0.28
Static Pressure (mm H O)
0.224
2
0.168
Static Pressure (inch H O)
0.112
2
Air Flow (CMM)
0.056
Static Pressure (mm H O)
2
Static Pressure (inch H O)
0
CFM-4020V-145-123
For more information, please visit the product page.
CUI Inc │ SERIES: CFM-40V │ DESCRIPTION: DC AXIAL FAN
date 07/21/2017 │ page 6 of 11
PERFORMANCE CURVES (CONTINUED)
CFM-4020V-170-255
0.168
0.224
0
3
0.12
1.5
0.06
0
2
4
6
8
Air Flow (CFM)
10
0.25
6.35
0.2
5.08
0.15
3.81
0.1
2.54
0.05
1.27
0
4
2
2
0.16
Static Pressure (inch H O)
0.22
5
3
0.12
0.08
2
0.04
1
0
2
0
3
6
9
12
Air Flow (CFM)
0
Air Flow (CMM)
0.165
Static Pressure (mm H O)
0.11
0.2
0
0.34
CFM-4020V-270-255
2
Static Pressure (inch H O)
0.055
0.255
7.62
Air Flow (CMM)
0
0.17
0.3
0
0
CFM-4020V-260-210
0.085
2
2
4.5
0.18
Static Pressure (inch H O)
6
Static Pressure (mm H O)
2
Static Pressure (inch H O)
0.24
0
Air Flow (CMM)
0.28
2
0.112
Static Pressure (mm H O)
Air Flow (CMM)
4
Air Flow (CFM)
6
8
0
0.112
0.168
0.224
0.28
0.24
6
0.18
4.5
0.12
3
0.06
1.5
0
cui.com
0.056
0
2
4
6
Air Flow (CFM)
8
10
0
2
0.056
Static Pressure (mm H O)
0
CFM-4020V-180-275
For more information, please visit the product page.
CUI Inc │ SERIES: CFM-40V │ DESCRIPTION: DC AXIAL FAN
date 07/21/2017 │ page 7 of 11
PERFORMANCE CURVES (CONTINUED)
CFM-4020V-280-275
Air Flow (CMM)
0.17
0.255
0.34
0.3
7.62
0.25
6.35
2
Static Pressure (mm H O)
0.085
2
Static Pressure (inch H O)
0
0.2
5.08
0.15
3.81
0.1
2.54
0.05
1.27
0
0
3
6
9
Air Flow (CFM)
12
0
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: CFM-40V │ DESCRIPTION: DC AXIAL FAN
date 07/21/2017 │ page 8 of 11
MECHANICAL
parameter
conditions/description
motor
4 pole DC brushless
min
bearing system
omniCOOLTM
direction of rotation
counter-clockwise viewed from front of fan blade
dimensions
CFM-4010V models: 40 x 40 x 10
CFM-4020V models: 40 x 40 x 20
material
PBT (UL94V-0)
weight
CFM-4010V models
CFM-4020V models
typ
max
units
mm
mm
15.6
29
g
g
MECHANICAL DRAWINGS
units: mm
MOUNTING SCREW (Pan Head)
wire: UL 1007, 26 AWG
CFM-4010V
WIRE CONNECTIONS
Wire Color
Function
Red
+Vin
Black
-Vin
White
RD Signal
Yellow1
Tach Signal
1
CFM-4020V
WIRE CONNECTIONS
Wire Color
Function
Red
+Vin
Black
-Vin
White
RD Signal
Yellow1
Tach Signal
1
Notes:
1. Wires only present on versions with output signals.
cui.com
Screw Type
Size
Machine Screw
M4
Self-tapping Screw
M5
Standard
Torque
JIS B1111-1974
3~4 kgf-cm
JIS B1122 Type 2 6~8 kgf-cm
For more information, please visit the product page.
CUI Inc │ SERIES: CFM-40V │ DESCRIPTION: DC AXIAL FAN
date 07/21/2017 │ page 9 of 11
APPLICATION NOTES
Auto Restart Protection
When the fan motor is locked by an external force, the device will temporarily turn off electrical power to the motor and
restart automatically when the locked rotor condition is released.
Input Current
Figure 1: Auto Start Protection
t
Run
Locked
Rotation Detector Signal (White Wire)
The rotation detector signal is used to detect if the fan motor is operating or stopped. The output will be logical low (VL)
when fan is operating and be logical high (Vcc) when fan motor is locked. (See Figures 2~3 below).
Figure 3: Rotation Detector
Output Circuit
Figure 2: Rotation Detector
Output Waveform
Vcc
Vsig
DC Fan
Vcc
Red (+)
Ic
RL
Vsig
White
VL
Black (-)
t
Run
Locked
Vcc ≤ max input voltage
Ic ≤ 4 mA
RL ≥ Vcc/Ic
VL ≤ 0.5 V
Customer Circuit
Tachometer Signal (Yellow Wire)
The tachometer signal is for detecting the rotational speed of the fan motor. The output will be a square wave when fan
is operating and logical high (Vcc) when fan motor is locked (See Figures 4~5 below). The relationship between RPM &
output pulses from the signal wire is as follows.
1 RPM = 2 Pulses
Figure 4: Tachometer
Output Waveform
Figure 5: Tachometer
Output Circuit
Vcc
Vsig
1 Pulse
DC Fan
Vcc
Red (+)
Yellow
VL
Ic
RL
Vsig
Black (-)
1 RPM
Run
t
Locked
Vcc ≤ max input voltage
Ic ≤ 4 mA
RL ≥ Vcc/Ic
VL ≤ 0.5 V
cui.com
Customer Circuit
For more information, please visit the product page.
CUI Inc │ SERIES: CFM-40V │ DESCRIPTION: DC AXIAL FAN
date 07/21/2017 │ page 10 of 11
SAFETY CONSIDERATIONS
1.
Do not use or operate this fan in excess of the limitations set forth in this specification. CUI is not responsible for the
non-performance of this fan and/or any damages resulting from its use, if it is not used or operated in accordance with
the specifications.
2.
CUI recommends adding a protection circuit to the product or application in which this fan is installed, such as a
thermo-fuse, or current fuse or thermo-protector. The failure to use such a device may result in smoke, fire, electric
shock by insulation degradation in cases of motor lead short circuit, overload, or over voltage, and/or other failure.
3.
CUI recommends installing a protection device to the product or application in which this fan is installed if there is a
possibility of reverse connection between Vdc (+) and GND (-). The failue to install such a device may result in smoke,
fire, and/or destruction, although these conditions may not manifest immediately.
4.
This fan mush be installed and used in compliance with all applicable safety standards and regulations.
5.
Use proper care when handling and/or installing this fan. Improper handling of installation of this fan may cause
damage that could result in unsafe conditions.
6.
Use proper care during installation and/or wiring. Failure to use proper care may cause damage to certain components
of the fan including, but not limited to, the coil and lead wires, which could result in smoke and/or fire.
7.
Do not use power or ground PWM to control the fan speed. If the fan speed needs to be adjusted, please contact CUI
to customize the product design for your application.
8.
For critical or extreme environments, including non-stop operation, please contact CUI and we will gladly provide
assistance with your product selection to ensure an appropriate cooling product for your application.
9.
When building your device, please examine thouroughly any variation of EMC, temperature rise, life data, quality, etc.
of this product by shock/drop/vibration testing, etc. If there are any problems or accidents in connection with this
product, it should be mutually discussed and examined.
10. Use proper care when handling these fans. Components such as fan holders or bearings may be damaged, if touched
with fingers or other objects. Additionally, static electricity (ESD) may damage internal circuits of the fan.
11. Do not operate these fans in proximity to hazardous materials such as organic silicon, cyanogens, formalin, phenol, or
corrosive gas environments including, but not limited to, H2S, SO2, NO2, or Cl2.
12. CUI recommends that you protect these fans from exposure to outside elements such as dust, condensation, humidity,
or insects. Exposure of this fan to such elements may affect its performance and my cause safety hazards. CUI does
not warrant against damage to the product caused by outside elements.
13. The fans must be installed properly and securely. Improper mounting may cause harsh resonance, vibration, and
noise.
14. Do not store these fans in an environment with high humidity. These fans must be stored in accordance with the
specified storage temperature.
15. CUI reserves the right to use components from multiple sources at its discretion. The use of components from other
sources will not affect the specifications as described herein.
16. The life expectancy of these fans has not been evaluated for use in combination with any end application. Therefore,
the life expectancy that relate to these fans are only for reference.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: CFM-40V │ DESCRIPTION: DC AXIAL FAN
date 07/21/2017 │ page 11 of 11
REVISION HISTORY
rev.
1.0
description
date
initial release
07/21/2017
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Similar pages