Mean Well HRP-450-3.3 450w single output with pfc function Datasheet

HRP-450
450W Single Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
High efficiency up to 89.5%
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in constant current limiting circuit
Built-in cooling Fan ON-OFF control
Built-in DC OK signal
Built-in remote sense function
5 years warranty
SPECIFICATION
MODEL
OUTPUT
HRP-450-3.3
HRP-450-5
HRP-450-7.5
HRP-450-12
HRP-450-15
HRP-450-24
HRP-450-36
HRP-450-48
DC VOLTAGE
3.3V
5V
7.5V
12V
15V
24V
36V
48V
RATED CURRENT
90A
90A
60A
37.5A
30A
18.8A
12.5A
9.5A
CURRENT RANGE
0 ~ 90A
0 ~ 90A
0 ~ 60A
0 ~ 37.5A
0 ~ 30A
0 ~ 18.8A
0 ~ 12.5A
0 ~ 9.5A
RATED POWER
297W
456W
450W
450W
450W
450W
451.2W
450W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
100mVp-p
120mVp-p
150mVp-p
150mVp-p
200mVp-p
240mVp-p
VOLTAGE ADJ. RANGE
4.3 ~ 5.8V
2.0%
6.8 ~ 9V
2.0%
10.2 ~ 13.8V
1.0%
13.5 ~ 18V
1.0%
21.6 ~ 28.8V
1.0%
28.8 ~ 39.6V
1.0%
40.8 ~ 55.2V
1.0%
2.8 ~ 3.8V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.3%
0.3%
0.2%
0.2%
0.2%
LOAD REGULATION
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
1000ms, 100ms/230VAC
HOLD UP TIME (Typ.)
16ms/230VAC
16ms/115VAC at full load
VOLTAGE RANGE
Note.5 85 ~ 264VAC
47 ~ 63Hz
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
120 ~ 370VDC
PF>0.95/230VAC
PF>0.99/115VAC at full load
EFFICIENCY (Typ.)
80%
83%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
5A/115VAC
35A/115VAC
2.4A/230VAC
70A/230VAC
LEAKAGE CURRENT
<1.5mA / 240VAC
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
FUNCTION
2500ms, 100ms/115VAC at full load
86.5%
88%
89%
88%
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
6 ~ 7V
9.4 ~ 10.9V
14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
3.96 ~ 4.62V
89%
89.5%
41.4 ~ 48.6V
57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
90
5
(70
5
5V only) (TSW1 : detect on heatsink of power transistor) ; 90
5
(TSW2 : detect on heatsink of power doide )
DC OK SIGNAL
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
FAN CONTROL (Typ.)
Load 20 10% or RTH2
WORKING TEMP.
-30 ~ +70
50
Fan on
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
EMC
(Note 4)
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
OTHERS
/ 70% RH
EMS IMMUNITY
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A
MTBF
139.9K hrs min.
DIMENSION
218*105*41mm (L*W*H)
1.19Kg; 12pcs/15.3Kg/0.83CUFT
PACKING
NOTE
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:HRP-450-SPEC 2010-03-24
HRP-450
450W Single Output with PFC Function
Mechanical Specification
Case No. 995A
Unit:mm
32.8
20.75
152.4
series
O/P
11
1
2
4
I/P
105
3
63.5
FAN
9.2
Air flow
direction
8.2
5
6
1
10
2
13
4-M4 L=5
3
218
32.8
152.4
18max.
LED
(Vo ADJ.)SVR1
CN100
24
12.5
41
18
12max.
AC Input Terminal Pin No.
Assignment
Pin No.
1
2
3
8-M4 L=4 (Both Sides)
Connector Pin No. Assignment(CN100) : HRS DF11-4DP-2DS or equivalent
DC Output Terminal Pin No.
Assignment
Pin No.
1~3
4~6
Assignment
AC/L
AC/N
FG
Terminal
Assignment Mating Housing
DC-OK
GND
HRS DF11-10DS HRS DF11-**SC
or equivalent
or equivalent
+S
-S
Pin No.
1
2
Assignment
-V
+V
3
4
Block Diagram
PMW fosc : 70KHz
I/P
+S
ACTIVE
INRUSH
CURRENT
LIMITING
EMI
FILTER
RECTIFIERS
&
PFC
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
-S
DETECTION
CIRCUIT
O.L.P.
O.T.P.
FG
PFC
CONTROL
O.T.P.
PWM
CONTROL
Derating Curve
DC OK
O.V.P.
Output Derating VS Input Voltage
Ta = 25
100
125
90
100
80
70
LOAD(%)
LOAD (%)
80
50
20
-30
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
100
125
135
155
264
INPUT VOLTAGE (V) 60Hz
File Name:HRP-450-SPEC 2010-03-24
HRP-450
450W Single Output with PFC Function
series
Function Description of CN100
Pin No. Function Description
DC-OK DC-OK Signal is a TTL level signal, referenced to pin2(DC-OK GND). High when PSU turns on.
1
GND This pin connects to the negative terminal(-V). Return for DC-OK signal output.
2
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
3
+S
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
4
-S
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
Function Manual
1.Remote Sense
The remote sensing compensates voltage drop on
the load wiring up to 0.5V.
CN100
2
4
CN100
1
3
2 GND DC-OK 1
4
+S
(Pin3)
-
+
LOAD
Fig 1.1
2.DC-OK Signal
DC-OK signal is a TTL level signal. High when PSU turns on.
Between DC-OK(pin5) and GND(pin6)
Output Status
3.3 ~ 5.6V
ON
0 ~ 1V
OFF
-S
+S
3
-S
(Pin4)
Sense lines should
be twisted in pairs
CN100
2
4
CN100
1
3
2
4
GND DC-OK
-S
+S
1
3
Fig 2.1
File Name:HRP-450-SPEC 2010-03-24