ME100SE Series Low Cost, 1W Ultra-Miniature SIP DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 1W Output Power Input Parameter • Ultra-Miniature SIP Case • Short Circuit Protected Input Voltage Range • 1,500 VDC Isolation • >3.5 MHour MTBF Input Filter • -40°C to +105°C Operation Output • LOW COST Parameter Output Voltage Accuracy Capacitive Load Line Regulation Load Regulation, See Note 1 Ripple & Noise (20 MHz), See Note 2 Conditions Min. 3.3 VDC Input 2.97 5 VDC Input 4.50 12 VDC Input 10.80 15 VDC Input 13.50 24 VDC Input 21.60 Internal Capacitor Typ. 3.3 5.0 12.0 15.0 24.0 Max. 3.63 5.50 13.20 16.50 26.40 Units Conditions Typ. ±3.0 Max. Units % µF % Min. For VIN Change of 1% See Model Selection Guide Output Voltage <12 VDC 30 15 VDC, 24 VDC Output 60 Temperature Coefficient Output Short Circuit 220 ±1.2 VDC mV P - P ±0.03 %/°C Typ. Max. 20 100 300 Units VDC M pF kHz Continuous (Autorecovery) General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance, See Note 3 Switching Frequency EMI Characteristics Parameter EMI Compliance, See Note 5 EMC Compliance Conditions 60 Seconds 500 VDC 100 kHz, 1V Conditions Min. 1,500 1,000 Min. Conducted Electrostatic Discharge (ESD) Typ. Max. Units CISPR22/EN 55022 Level B EN 61000-4-2 Level B Contact ±8 kV Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Conditions Min. Typ. -40 +25 -55 Free Air Convection RH, Non-condensing Ambient Max. +105 +125 Units °C °C 95 % 0.46 x 0.23 x 0.394 Inches (11.6 x 6.0 x 10.0 mm) Non-Conductive Black Plastic (UL-94V0) 0.04 Oz (1.2g) Reliability Specifications Parameter MTBF Conditions MIL HDBK 217F, 25°C, Gnd Benign Min. 3.5 Typ. Max. Units MHours Conditions 3.3 VDC Input 5 VDC Input 12 VDC Input 12 VDC Input 24 VDC Input 1.5 mm From Case For 10 Sec Min. -0.7 -0.7 -0.7 -0.7 -0.7 Typ. Max. 5.0 9.0 18.0 21.0 30.0 300 Units Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC °C www.micropowerdirect.com Model Selection Guide Input Model Number ME103S-05E Output Voltage (VDC) Current (mA) Voltage Current Current Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) 3 2.97 - 3.63 380 30 5.0 200.0 20.0 Rating Efficiency Fuse Slow-Blow (%, Typ) (mA) Load Regulation % Typ. 12.0 % Max 15.0 80 750 ME105S-05E 5 4.5 - 5.5 250 20 5.0 200.0 20.0 12.0 15.0 80 500 ME105S-09E 5 4.5 - 5.5 250 20 9.0 111.0 12.0 8.0 15.0 80 500 ME105S-12E 5 4.5 - 5.5 248 20 12.0 84.0 9.0 7.0 15.0 81 500 ME105S-15E 5 4.5 - 5.5 248 20 15.0 67.0 7.0 6.0 15.0 81 500 ME105S-24E 5 4.5 - 5.5 248 20 24.0 42.0 4.0 5.0 15.0 81 500 ME112S-05E 12 10.8 - 13.2 104 15 5.0 200.0 20.0 12.0 15.0 80 200 ME112S-09E 12 10.8 - 13.2 104 15 9.0 111.0 12.0 8.0 15.0 80 200 ME112S-12E 12 10.8 - 13.2 103 15 12.0 84.0 9.0 7.0 15.0 81 200 ME112S-15E 12 10.8 - 13.2 103 15 15.0 67.0 7.0 6.0 15.0 80 200 ME115S-15E 15 13.5 - 16.5 82 10 15.0 67.0 7.0 6.0 15.0 81 200 ME124S-05E 24 21.6 - 26.4 52 7 5.0 200.0 20.0 12.0 15.0 80 100 ME124S-09E 24 21.6 - 26.4 52 7 9.0 111.0 12.0 8.0 15.0 80 100 ME124S-12E 24 21.6 - 26.4 50 7 12.0 84.0 9.0 7.0 15.0 81 100 ME124S-15E 24 21.6 - 26.4 50 7 15.0 67.0 7.0 6.0 15.0 82 100 ME124S-24E 24 21.6 - 26.4 50 7 24.0 42.0 4.0 5.0 15.0 82 100 Notes: 1. Output load regulation is specified for a load change of 10% to 100%. 2. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin. 3. The isolation capacitance of model ME124S-24E is 30 pF. 4. Operation at no load will not damage these units, however, they may not meet all specifications. 5. These converters are specified for operation without external components. However, in some applications the addition of input/output capacitors will enhance stability and reduce output ripple. The simple connection shown below will typically meet EN 55022 Class B. Pin Connections Pin Description Pin Description 1 -VIN 3 -VOUT 2 +VIN 4 +VOUT Mechanical Dimensions Me VIN C1 L1 C2 VOUT C3 3.3 VDC 5 VDC 12 VDC 15 VDC 24 VDC 4.7 µF/50V 4.7 µF/50V 4.7 µF/50V 4.7 µF/50V 4.7 µF/50V 6.8 µH 6.8 µH 6.8 µH 6.8 µH 6.8 µH ------470 pF/2kV 470 pF/2kV 5 VDC 9 VDC 12 VDC 15 VDC 24 VDC 10 µF 4.7 µF 2.2 µF 1.0 µF 0.47 µF 6. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Derating Curve MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) • Pin 1 is marked by a “dot” or indentation on the unit FAX: (781) 344-8481 • E-Mail: [email protected]