AIMTEC AM5T-2424DH35-VZ 5 watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM5T-VZ
5 Watt | DC-DC Converter
FEATURES:








Wide 2:1 input range
24 Pin DIP Package
Metal package
High efficiency up to 80%
Operating temperature -40oC to + 85oC
Input / Output isolation 1500 & 3500 VDC
Pin compatible with multiple manufacturers
Continuous short circuit protection
Models
Single output
Model
AM5T-1205S-VZ
AM5T-1209S-VZ
AM5T-1212S-VZ
AM5T-1215S-VZ
AM5T-1224S-VZ
AM5T-2405S-VZ
AM5T-2409S-VZ
AM5T-2412S-VZ
AM5T-2415S-VZ
AM5T-2424S-VZ
AM5T-4805S-VZ
AM5T-4809S-VZ
AM5T-4812S-VZ
AM5T-4815S-VZ
AM5T-4824S-VZ
AM5T-1205SH35-VZ
AM5T-1209SH35-VZ
AM5T-1212SH35-VZ
AM5T-1215SH35-VZ
AM5T-1224SH35-VZ
AM5T-2405SH35-VZ
AM5T-2409SH35-VZ
AM5T-2412SH35-VZ
AM5T-2415SH35-VZ
AM5T-2424SH35-VZ
AM5T-4805SH35-VZ
AM5T-4809SH35-VZ
AM5T-4812SH35-VZ
AM5T-4815SH35-VZ
AM5T-4824SH35-VZ
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Capacitive load,
max (μF)
Efficiency
(%)
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-72
36-72
36-72
36-72
36-72
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-72
36-72
36-72
36-72
36-72
5
9
12
15
24
5
9
12
15
24
5
9
12
15
24
5
9
12
15
24
5
9
12
15
24
5
9
12
15
24
1000
555
416
333
208
1000
555
416
333
208
1000
555
416
333
208
1000
555
416
333
208
1000
555
416
333
208
1000
555
416
333
208
2200
470
470
470
220
2200
470
470
470
220
2200
470
470
470
220
2200
470
470
470
220
2200
470
470
470
220
2200
470
470
470
220
74
77
78
78
75
75
76
77
78
76
77
78
80
80
77
74
77
78
78
75
75
76
77
78
76
77
78
80
80
77
Input Voltage
(V)
Output Voltage
(V)
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-72
±5
±9
±12
±15
±24
±5
±9
±12
±15
±24
±5
Models
Dual output
Model
AM5T-1205D-VZ
AM5T-1209D-VZ
AM5T-1212D-VZ
AM5T-1215D-VZ
AM5T-1224D-VZ
AM5T-2405D-VZ
AM5T-2409D-VZ
AM5T-2412D-VZ
AM5T-2415D-VZ
AM5T-2424D-VZ
AM5T-4805D-VZ
www.aimtec.com
F 051e R12.I
Output Current
max (mA)
±500
±277
±208
±166
±104
±500
±277
±208
±166
±104
±500
Tel: +1 514 620 2722
1 of 4
Capacitive load,
max (μF)
±1000
±220
±220
±220
±100
±1000
±220
±220
±220
±100
±1000
Efficiency
(%)
72
76
77
77
80
74
76
78
78
75
76
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM5T-VZ
5 Watt | DC-DC Converter
Models
Dual output (continued)
Model
Input Voltage
(V)
Output Voltage
(V)
36-72
36-72
36-72
36-72
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-72
36-72
36-72
36-72
36-72
±9
±12
±15
±24
±5
±9
±12
±15
±24
±5
±9
±12
±15
±24
±5
±9
±12
±15
±24
AM5T-4809D-VZ
AM5T-4812D-VZ
AM5T-4815D-VZ
AM5T-4824D-VZ
AM5T-1205DH35-VZ
AM5T-1209DH35-VZ
AM5T-1212DH35-VZ
AM5T-1215DH35-VZ
AM5T-1224DH35-VZ
AM5T-2405DH35-VZ
AM5T-2409DH35-VZ
AM5T-2412DH35-VZ
AM5T-2415DH35-VZ
AM5T-2424DH35-VZ
AM5T-4805DH35-VZ
AM5T-4809DH35-VZ
AM5T-4812DH35-VZ
AM5T-4815DH35-VZ
AM5T-4824DH35-VZ
Output Current
max (mA)
Capacitive load,
max (μF)
±277
±208
±166
±104
±500
±277
±208
±166
±104
±500
±277
±208
±166
±104
±500
±277
±208
±166
±104
Efficiency
(%)
±220
±220
±220
±100
±1000
±220
±220
±220
±100
±1000
±220
±220
±220
±100
±1000
±220
±220
±220
±100
78
78
80
77
72
76
77
77
80
74
76
78
78
75
76
78
78
80
77
Maximum
Units
Input Specifications
Parameters
Voltage Range
Nominal
Typical
12
24
48
9-18
18-36
36-72
12 Vin
24 Vin
48 Vin
20
-0.7-24
-0.7-40
-0.7-80
15
 (Pi) Network
Filter
Start up time
Absolute Maximum Rating
VDC
Peak Input Voltage time
ms
VDC
ms
Isolation Specifications
Parameters
Tested I/O voltage
Conditions
Typical
3 sec
Resistance
Capacitance
Rated
Units
1500 (3500 H35
model)
VDC
> 1000
60
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Voltage balance
Conditions
Typical
Maximum
±1
Balanced Load
±1
Short circuit protection
Continuous
Short circuit restart
Auto Recovery
Line voltage regulation
HL-LL
±0.5
Load voltage regulation
25-100% Load
±0.5
Temperature coefficient
±0.02
Ripple & Noise (see note)
At 20MHz Bandwidth
60
Note: For ripple and noise specification, a 100 µF capacitor must be placed on the output of converter.
www.aimtec.com
F 051e R12.I
Tel: +1 514 620 2722
2 of 4
Units
%
%
%
%
%/oC
mV p-p
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM5T-VZ
5 Watt | DC-DC Converter
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
Dimensions(L x W x H)
MTBF
Conditions
Typical
Maximum
Units
100
KHz
oC
oC
oC
100-400
Full Load (see derating chart)
-40 to +85
-40 to +125
Free air convection
95
%
Nickel coated copper
12.16
g
Tolerance ±0.5 mm or ±0.02 inches
1.25 x 0.8 x 0.4 inches
31.75 x 20.32 x 10.16 mm
>2,200,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
Safety Specifications
Parameters
Agency approvals
CE
Standards
Designed to meet IEC 60950-1
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Pin Out Specifications
Pin
2
3
9
11
14
16
22
23
1500 and 3500VDC
Single
Dual
-V Input
-V Input
No pin
N.C.
+V Output
-V Output
+V Input
+V Input
-V Input
-V Input
Common
-V Output
+V Output
Common
+V Input
+V Input
3.05
(0.12)
10.50
(0.41)
21.35
(0.84)
15.24
(0.60)
Dimensions
www.aimtec.com
F 051e R12.I
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM5T-VZ
5 Watt | DC-DC Converter
Derating
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.I
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages