MEAN WELL MWP-602(A) (53020) MWP-606(A) SWITCHING POWER SUPPLY ISO-9001 CERTIFIED MANUFACTURER .LOW COST, HIGH RELIABILITY .COMPACT SIZE, LIGHT WEIGHT .105ºC OUTPUT CAPACITOR .100% FULL LOAD BURN-IN TEST .INTERNATIONAL AC INPUT RANGE .OUTPUT VOLTAGE CORRECTION LED .BUILT IN EMI FILTER, LOW RIPPLE NOISE .HIGH EFFICIENCY, LOW WORKING TEMPERATURE .SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT .SHORT CIRCUIT, OVERLOAD PROTECTED MWP-602/MWP-602A/(53020) MODEL SPECIFICATION MWP-606/MWP-606A CH1 CH2 CH3 CH1 CH2 CH3 5V 12V -5V 5V 12V -5V OUTPUT V. TOLERANCE ±2% ±8% ±10% ±2% ±8% ±10% OUTPUT RATED CURRENT 15A 2A 1A 15A 2A 1A DC OUTPUT VOLTAGE OUTPUT CURRENT RANGE 3-15A 0.2-3A 0.1-1A 3-15A 0.2-4A 0.1-1A 50mVp-p 120mVp-p 60mVp-p 50mVp-p 120mVp-p 60mVp-p LINE REGULATION ±0.5% ±1% ±1% ±0.5% ±1% ±1% LOAD REGULATION ±1% ±6% ±8% ±1% ±6% ±8% RIPPLE & NOISE DC OUTPUT POWER 104W 104W EFFICIENCY 75% 75% CH1:4.7~5.8Vref. CH1:4.75~5.5Vref. DC VOLTAGE ADJ. INPUT VOLTAGE RANGE 88~132VAC / 176~264VAC SELECTED BY SWITCH 47~63Hz; 240~370VDC AC CURRENT 2.6A/115V 1.3A/230V INRUSH CURRENT COLD START 20A/115V 40A/230V LEAKAGE CURRENT <0.5mA/240VAC OVERLOAD PROTECTION 105%~150% TYPE:FOLDBACK CURRENT SHUTDOWN RESET:RE-POWER ON OVER VOLTAGE PROTECTION ---------- OPERATING DISPLAY 602A, 606A DOUBLE COLOR LED CORRECT RANGE:GREEN(5~5.4Vref.) WRONG RANGE:RED TEMP. COEFFICIENT ±0.05% / ºC (0~50ºC) ON +5V OUTPUT SETUP, RISE, HOLD UP TIME 200ms, 50ms, 16ms VIBRATION 10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES WITHSTAND VOLTAGE I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms WORKING TEMP., HUMIDITY -10ºC~+60ºC(REFER TO OUTPUT DERATING CURVE), 20%~90% RH STORAGE TEMP., HUMIDITY -20ºC~+85ºC, 10%~95% RH DIMENSION 180*110*50mm CASE:602 203*115*50mm WITH TERMINAL & FIXED IRON WEIGHT 0.9Kgs SAFETY STANDARDS MEET UL1012 REQUIREMENT (NOT APPLY FOR THE MARK) UL1950, TUV EN60950 APPROVED EMC STANDARDS --------- CISPR22 (EN55022) CLASS B, IEC801-2,3,4, IEC555-2 VERIFICATION NOTE : 1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25ºC 70% RH. AMBIENT. 2.TOLERANCE GINCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION. 3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR. 4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD. 5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD. 6.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TOTAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER. JUN.09.98