Rectron FMM120 Low vf schottky barrier rectifier Datasheet

FMM120
THRU
FMM140
LOW Vf SCHOTTKY BARRIER RECTIFIER
VOLTAGE RANGE 20 to 40 Volts CURRENT 1.0 Ampere
FEATURES
*
*
*
*
*
*
Low switching noise
Low forward voltage drop
High current capability
High switching capability
High surge capabitity
High reliability
DO-214AC
MECHANICAL DATA
*
*
*
*
*
*
0.067 (1.70 )
0.051 (1.29 )
Case: Molded plastic
Epoxy: Device has UL flammability classification 94V-O
Lead: MIL-STD-202E method 208C guaranteed
Metallurgically bonded construction
Mounting position: Any
Weight: 0.09 gram
0.110 ( 2.79 )
0.086 ( 2.18 )
0.180 ( 4.57 )
0.160 ( 4.06 )
0.012 ( 0.305 )
0.006 ( 0.152 )
0.091 ( 2.31 )
0.067 ( 1.70 )
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
0.059 ( 1.50 )
0.035 ( 0.89 )
0.008 ( 0.203 )
0.004 ( 0.102 )
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
0.209 ( 5.31 )
0.185 ( 4.70 )
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
FMM120
FMM130
FMM140
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
20
30
40
Volts
Maximum RMS Voltage
VRMS
14
21
28
Volts
VDC
20
30
40
Volts
RATINGS
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at T A=75 OC
IO
1.0
Amps
I FSM
40
Amps
Typical Thermal Resistance (Note 1)
RqJA
85
0
C/W
Typical Thermal Resistance (Note 1)
RqJL
25
0
C/W
Typical Junction Capacitance (Note 2)
CJ
110
pF
Operating Temperature Range
TJ
150
0
C
T STG
-55 to + 150
0
C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Storage Temperature Range
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 1.0A DC
Maximum Average Reverse Current
@T A = 25 o C
at Rated DC Blocking Voltage
@T A = 100 o C
SYMBOL
VF
IR
NOTES : 1. Thermal Resistance : Mounted on PCB.
2. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
3. Also available in DO-214AA (SMB).
4. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
FMM120
FMM130
FMM140
UNITS
.44
Volts
1.0
mA
10
mA
2006-11
1.0
Single Phase Half Wave
60Hz Inductive Load
0.75
0.50
0.25
0
P.C.B. Mounted on
0.4X0.4"(10X10mm)
copper pad areas
0
25
50
75
100
125
150
175
INSTANTANEOUS FORWARD CURRENT, (mA)
AVERAGE FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( FMM120 THRU FMM140 )
100
10
1.0
TA = 100 OC
TA = 75 OC
0.1
TA = 25 OC
0.01
0.001
0
20
O
CJ, JUNCTION CAPACITANCE, (pF)
20
10
1.0
0.1
TJ = 25 OC
Pulse width=300mS
1% Duty Cycle
0.1
0.3
0.5
0.7
0.9
1.1
1.3
1.5
40
60
100
120
140
1.7
400
TJ = 25 OC
200
100
80
60
40
20
10
1.9 2.1
FIG.2 TYPICAL REVERSE
CHARACTERISTICS
0.1
0.4
INSTANTANEOUS FORWARD VOLTAGE, (V)
1.0
4
10
40 80
REVERSE VOLTAGE, (V)
FIG.3 TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
FIG.4 TYPICAL JUNCTION CAPACITANCE
50
8.3mS Single Half Sine-Wave
JEDEC Method
40
30
20
10
0
1
80
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (A)
AMBIENT TEMPERATURE, ( C)
2
4
6
8 10
20
40
80 100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
Mounting Pad Layout
0.094 MAX.
(2.38 MAX.)
0.060MIN.
( 1.52 MIN.)
0.052 MAX.
(1.32 MAX.)
0.220
(5.58) REF
Dimensions in inches and (millimeters)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
Similar pages