MORNSUN G1212KS-1W Dual output dc-dc converter Datasheet

.
G1212KS-1W
1W, FIXED INPUT, 6000V ISOLATED & UNREGULATED
DUAL OUTPUT DC-DC CONVERTER
RoHS
PRODUCT PROGRAM
FEATURES
● Small Footprint
● SIP Package
● Low Isolation Capacitance
● 6KVDC Isolation
● Temperature Range: -40°C to +85°C
● No External Component Required
● No Heat Sink Required
● Internal SMD Construction
● Industry Standard Pinout
● RoHS Compliance
Input
Part
Number
Output
Voltage (VDC)
Nominal
Range
Voltage
(VDC)
12
10.8-13.2
±12
G1212KS-1W
Efficiency
(%, Typ.)
Current (mA)
Max.
Min.
±42
±5
72
APPLICATIONS
The G1212KS-1W is specially designed for
applications where a group of polar power
supplies are isolated from the input power
supply in a distributed power supply system on a
circuit board.
These products apply to:
1)
Where the voltage of the input power
supply is fixed (voltage variation ≤ ±10%);
2)
Where isolation is necessary between
input and output (isolation voltage ≤6000VDC);
3)
COMMON SPECIFICATIONS
Item
Test conditions
Where the regulation of the output
Storage humidity range
voltage and the output ripple noise are not
Operating temperature
demanding.
Such as: purely digital circuits, ordinary low
frequency analog circuits, and IGBT power
Min.
Storage temperature
Lead temperature
Temp. rise at full load
MODEL SELECTION
Cooling
G1212KS-1W
Case material
%
-55
125
°C
300
15
25
Continuous
Free air convection
Plastic(UL94-V0)
MTBF
3500
Weight
K hours
4.2
g
SPECIFICATIONS
MORNSUN Science & Technology Co.,Ltd.
Item
Test Conditions
Min.
Address: No. 5, Kehui St. 1, Kehui development
Isolation voltage
Tested for 1 minute and 1mA max
6000
Isolation resistance
Test at 500VDC
1000
center, Science Ave., Guangzhou Science City,
Luogang district, Guangzhou,P.R.China.
Tel: 86-20-38601850
Fax:86-20-38601272
Http://www.mornsun-power.com
Units
95
85
Short circuit protection
ISOLATION
Max.
-40
1.5mm from case for 10 seconds
device driving circuits.
Rated Power
Package Style
Output Voltage
Input Voltage
Product Series
Typ.
Isolation capacitance
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Typ.
Max.
Units
VDC
MΩ
10
pF
Specifications subject to change without notice.
G1212KS-1W
A/2-2012
Page 1 of 3
OUTPUT SPECIFICATIONS
Item
Test Conditions
Output power
TYPICAL CHARACTERISTICS
Min.
Typ.
Max.
Units
1
W
0.1
Line regulation
For Vin change of 1%
Load regulation
10% to 100% load
Output voltage accuracy
±1.2
6.8
15
%
See tolerance envelope graph
Temperature drift
100% full load
Ripple & Noise*
20MHz Bandwidth
150
Switching frequency
Full load, nominal input
50
0.03
%/°C
200
mVp-p
KHz
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power
Converter section, application notes.
Dual output models unbalanced load: ±5%.
Operating Temp.(oC)
APPLICATION NOTE
RECOMMENDED CIRCUIT
L
L
Requirement on output load
To ensure this module can operate efficiently and reliably, During operation, the minimum
Vin
output load could not be less than 10% of the full load. If the actual output power is very
GND
+Vo
Cout
DC DC
Cin
0V
L Cout
-Vo
small, please connect a resistor with proper resistance at the output end in parallel to
(Figure 1)
increase the load, or use our company’s products with a lower rated output power.
Vin
REG
Recommended testing and application circuit
If you want to further decrease the input/output ripple, an “LC” filtering network may be
GND
REG
+Vo
REG
-Vo
0V
DC DC
connected to the input and output ends of the DC/DC converter, see (Figure 1).
(Figure 2)
It should also be noted that the inductance and the frequency of the “LC” filtering network
should be staggered with the DC/DC frequency to avoid mutual interference. However, the
capacitance of the output filter capacitor must be proper. If the capacitance is too big, a
EXTERNAL CAPACITOR TABLE (TABLE 1)
startup problem might arise. For every channel of output, provided the safe and reliable
Vin
(VDC)
Cin
(uF)
Dual Vout
(VDC)
Cout
(uF)
12
2.2
±12
2.2
operation is ensured, the greatest capacitance of its filter capacitor sees (Table 1).
Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output voltage regulation, over-voltage and over-current protection
is a linear voltage regulator with overheat protection that is connected to the input or output
end in series (Figure 2).
It’s not recommended to connect any external
capacitor in the application field with less than
0.5 watt output.
Overload Protection
Under normal operating conditions, the output circuit of these products has no
protection against overload. The simplest method is to connect a self-recovery fuse in series
at the input end or add a circuit breaker to the circuit.
No parallel connection or plug and play
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
G1212KS-1W
A/2-2012
Page 2 of 3
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT
∅1.00 [0.039]
(Fron t View)
1
12.50 [0.492]
4.10 [0.161]
2
5
6
7
Note: grid 2.54*2.54mm .
0.50 [0.020]
0.50 [0.020]
TUBE OUTLINE DIMENSIONS
1
(Bo tto m Vie w)
2
5 6
7
2.54 [0.100]
9.8 0 [0.386]
2 .40 [0.094]
12.40 [0.488]
19.50 [0.768]
14.40 [0.567]
20.40 [0.803]
0.30 [0.012]
15.24 [0.600]
FOOTPRINT DETAIL S
Func tion
Pin
1
Vin
2
GND
-Vo
5
6
0V
+Vo
7
Note:
Unit:mm[inch]
Pin section tolerances:±0.10mm[±0.004inch]
General tolerances:±0.25mm[±0.010inch]
6.40 [0.252]
Note:
Unit :mm[inch]
General tolerances: ±0.50mm[±0.020inch]
L=530mm[20.866inch] Tube Quantity: 25pcs
L=220mm[8.661inch]
Tube Quantity: 10pcs
Short tube inner package dimensions: L*W*H= 255*170*80mm
Short tube outer package dimensions(with six inner package boxes):
L*W*H= 375*280*270mm
Long tube inner package dimensions: L*W*H= 580*200*100mm
Long tube outer package dimensions(with two inner package boxes):
L*W*H= 600*215*220mm
Long tube outer package dimensions(with three inner package boxes):
L*W*H= 600*215*325mm
Note:
1. Operation under minimum load will not damage the converter; However, they may not meet all specification listed, and that will reduce
the life of product.
2. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
3. In this datasheet, all the test methods of indications are based on corporate standards.
4. Only typical models listed, other models may be different, please contact our technical person for more details.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
G1212KS-1W
A/2-2012
Page 3 of 3
Similar pages