Fiber Optic Transmitter MOF-T3K5 Outline Dimensions Features 1.Uni-directional data transmission using plastic fiber 2.Signal transmission speed :MAX. 8 Mbps (NRZ signal) 3.Operating voltage :4.75 to 5.25 V 4.TTL and high speed C-MOS LOGIC IC compatible Recommended drilling as viewd from the soldering face NOTES: Tolerance is ±0.3mm unless otherwise noted. @TA=25oC Absolute Maximum Ratings Parameter Symbol Rating Unit Supply voltage Vcc -0.5 to + 7.0 V Input voltage Vin -0.5 to Vcc +0.5 Operating temperature Storage temperature Soldering temperature *1 Topr -20 to +70 Tstg -30 to +80 Tsol 260 V o C C o C o *1 For 5s (2 times or less) REV : A1 Unity Opto Technology Co., Ltd. 09/11/2001 1/4 Fiber Optic Transmitter Recommended Operating Conditions Parameter Operating supply voltage Operating transfer rate Electro-Optical Characteristics Parameter Peak emission wavelength Optical power output coupling with fiber Dissipation current High level input voltage Low level input voltage Low →High delay time High →Low delay time Pulse width distortion MOF-T3K5 Symbol Vcc T MIN. 4.75 --- TYP. 5.0 --- MAX. 5.25 8 Unit V Mbps Symbol Conditions λp Pc Icc ViH Refer to Fig. 1 Refer to Fig. 2 Refer to Fig. 2 ViL tpLH tpHL ∆tw Refer to Fig. 2 Refer to Fig. 3 Refer to Fig. 3 Refer to Fig. 3 MIN. 630 -21 --2.1 -------25 TYP. 660 -18 8 ----120 120 --- MAX. 690 -15 13 Vcc 0.8 ----+25 Unit nm dBm mA V V ns ns ns REV : A1 Unity Opto Technology Co., Ltd. 09/11/2001 2/4 Fiber Optic Transmitter MOF-T3K5 Fig. 1 Measuring Method of Optical Output Coupling with Fiber Standard optical fiber cable MOF-T3K5 Unit to be measured VCC Vin Optical power meter The optical power meter must be calibrated to have the wavelength sensitivity of 660 nm. ( 0dBm=1mW ) GND D VCC Notes (1)Vcc=5.0V (State of operating) (2)To bundle up the standard fiber optic cable, make it into a loop with the diameter D=10cm or more. Fig. 2 Measuring Method of Intput Voltage and Supply Current Standard optical fiber cable MOF-T3K5 Unit to be measured Vin Vin VCC The optical power meter must be calibrated to have the wavelength sensitivity of 660 nm. ( 0dBm=1mW ) GND Icc VCC Input conditions and judgement method Conditions Vin=2.1V or more Vin=0.8V or less Judgement method -21dBm<=Pc<=-15dBm, Icc=13mA or less Pc<=-36dBm, Icc=13mA or less Note: Vcc=5.0V (State of operating) REV : A1 Unity Opto Technology Co., Ltd. 09/11/2001 3/4 Fiber Optic Transmitter MOF-T3K5 Fig.3 Measuring Method of Pulse Response Standard optical fiber cable Standard receiver MOF-T3K5 Unit to be measured VCC Output signal GND Vin Oscilloscope VCC CH1 CH2 Input Input signal 1 1 0 50% 0 t PLH 4Mbps biphase PRBS signal t PHL Standard receiver output 50% Test item Test item Low →High pulse delay time High →Low pulse delay time Pulse width distortion Notes Symbol Test condition t PLH Refer to the above prescriptions t PHL Refer to the above prescriptions ∆tw ∆tw=t PHL- t PLH (1) The waveform write time shall be 4 seconds. But do not allow the waveform to be distorted by increasing the brightness too much. (2 ) Vcc=5.0 V (State of operating) (3) The probe for the oscilloscope must be more than 1M and less than 10pF. REV : A1 Unity Opto Technology Co., Ltd. 09/11/2001 4/4