Type Cold Cathode Lamp Inverter Drive module 12VDC input Connector system JST XHP-2 Part No. INV 5 (OA-0012-8045D) TR1 + C1 R1 CCFL output Connector system JST XHP-3 T1 R2 L1 C2 TR2 Drawing not to scale All dimensions in mm CHARACTERISTIC DATA Dual Output suitable for CCFL length: Input Voltage Input Current No Load Output Voltage Lamp Output Voltage (VL) Nominal Drive current (IL) 50 ~ 150 mm 12VDC ± 1.5V 450 mA maximum 800V rms minimum, 1200V rms nominal 350V rms nominal 5.5 mA ± 1mA Operating frequency (f) Operating temperature Operating humidity 35 ± 5 kHz 0 ~ 50 ºC 5 ~ 70% RH NOTES: 1. The inverter module should be protected from moisture, condensation and freezing. 2. Suitable screening may be necessary for electromagnetic compatibility and protection. 3. The use of silicone rubber stranded wire is recommended for connecting the CFFL 4. Danger of electric shock.