The ACTF4158 is a low-loss, compact, and economical surface-acoustic-wave (SAW) filter in a
surface-mount ceramic DCC6 case with 457.50 MHz center frequency.
1. Package Dimension (DCC6)
Pin
Configuration
2
Input
5
Output
1, 3, 4, 6
Ground
Unit: mm
2. Marking
- The logo “ND” indicates our product’s mark
ACTF*001
4158
●
- The character “F” indicates the type of SAW component
Including: F (filter), R (resonator) etc.
- The “4158” indicates the model name of SAW component
- The character “*” indicates the month code in a year
2005
2006
2007
2008
1
A
N
a
n
2
B
P
b
p
3
C
Q
c
q
4
D
R
d
r
5
E
S
e
s
6
F
T
f
t
7
G
U
g
u
8
H
V
h
v
9
J
W
j
w
10
K
X
k
x
11
L
Y
l
y
12
M
Z
m
z
- The characters “001” indicate the lot number of mounting
Including: 001~999
1
3. Maximum Ratings
Rating
Value
Unit
Operable Temperature Range
TA
-30 to +80
℃
Storage Temperature Range
Tstg
-40 to +85
℃
DC Voltage (between each Terminal)
VDC
0
V
RF Power (in BW)
P
30 max.
dBm
ESD Voltage (HB)
V
150
V
4. Electrical Characteristics
Characteristic
Minimum
Typical
Maximum
Unit
Center Frequency
fC
--
457.50
--
MHz
User Signal Band
BW
454.5
--
460.5
MHz
--
2.1
2.4
dB
27
25
40
22
27
20
32
30
42
27
32
24
------
dB
dB
dB
dB
dB
dB
--
1.0
1.5
dB
--
1.5
2.0
--
-36
--
Insertion Loss
IL
454.5 …
Absolute Attenuation
0.3
350.0
465.0
470.0
907.5
917.5
460.5 MHz
α
… 350.0 MHz
… 445.0 MHz
… 470.0 MHz
… 907.5 MHz
… 917.5 MHz
... 1500.0 MHz
Passband Ripple
454.5 …
Δα
460.5 MHz
VSWR
SWR
454.5 …
460.5 MHz
Temperature Coefficient of Frequency
Input / Output Impedance
TCf
ppm/
50
Ω
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling!
NOTE:
1.
2.
3.
4.
The frequency fC is defined as the midpoint between the 3dB frequencies.
Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is connected
to a 50Ω test system with VSWR≤1.2:1.
Unless noted otherwise, specifications apply over the entire specified operating temperature range.
The specifications of this device are based on the test circuit shown below and subject to change or obsolescence without
notice.
2
5. Test Circuit
5. Performance
3
7. Environmental Characteristics
Test item
Condition of test
Requirements
1
Mechanical
shock
(a) Drops: 3 times on concrete floor
(b) Height: 1.0m
2
Vibration
resistance
(a) Frequency of vibration: 10~55Hz (b) Amplitude: 1.5mm
(d) Duration: 2 hours
(c) Directions: X,Y and Z
3
Moisture
resistance
(a) Condition: 40C, 90~95% R.H.
(c) Wait 4 hours before measurement
Climatic
sequence
(a) +70 for 16 hours
(b) +55 for 24 hours, 90~95% R.H.
(c) -25 for 2 hours
(d) +40 for 24 hours, 90~95% R.H.
(e) Wait 4 hours before measurement
5
High
Temperature
Exposure
(a) Temperature: 70C
(b) Duration: 250 hours
(c) Wait 4 hours before measurement
6
Thermal impact
(a) +70C for 30 minutes  -25C for 30 minutes repeated 3 times
(b) Wait 4 hours before measurement
4
(b) Duration: 96 hours
The SAW filter
shall remain within
the electrical
specifications
after tests.
8. Remarks
8-1 Static voltage: Static voltage between signal load & ground may cause deterioration & destruction
of the SAW filter. Please avoid static voltage.
8-2 Ultrasonic cleaning: Ultrasonic vibration may cause deterioration & destruction of the SAW filter.
Please avoid ultrasonic cleaning.
8-3 Soldering: Only terminals of the SAW filter may be soldered.
the SAW filter.
Please avoid soldering other parts of
4
9. Packing
9-1. Carrier Tape
9-2. Reel Dimensions
10. Soldering Profile
5