CIT J115F21BL9VDCN.6U Ul f class rated standard Datasheet

J115F2
RoHS Compliant
R
E197852
31.9 x 26.8 x 28.1 mm
Features
eatures
•
•
•
•
UL F class rated standard
Small size and light weight, low coil power consumption
Heavy contact load, strong shock and vibration resistance
UL/CUL, TÜV certified
Contact Data*
UL Contact Rating N.O.
5A @ 280VAC Ballast
TÜV Contact Rating N.O. 40A @ 240VAC; 14VDC
30A @ 277VAC
5A @ 280VAC General Purpose
N.C.
20A @ 240VAC Resistive, 250k cycles, 40C
30A @ 240VAC; 14VDC
20A @ 277VAC
25A @ 277VAC, Resistive 100k cycles, 40C
40A @ 240VAC Resistive, 40C
30A @ 277VAC General Purpose
Contact Arrangement
1A = SPST N.O.
2hp @ 250VAC, 40C; 1hp @ 125VAC,
1B = SPST N.C.
50K cycles, 40C
N.C.
1C = SPDT
5A @ 280VAC Ballast
5A @ 280VAC General Purpose
30A @ 240VAC Resistive, 40C
30A @ 30VDC, 40C
20A @ 277VAC General Purpose
1-1/2hp @ 250VAC; 1/4hp @
125VAC, 50K cycles, 40C
Contact Resistance
< 30 milliohms initial
Contact Material
AgSnO2 AgSnO2In2O3
Maximum Switching Power
9600VA, 1120 W
Maximum Switching Voltage
277VAC, 110VDC
Maximum Switching Current
40A
Coil Data DC Parameters*
Coil Voltage
VDC
Coil Resistance
Ω +/- 10%
Pick Up Voltage Release Voltage
VDC (max)
VDC (min)
Rated
Max
.6W
.9W
75% of rated
voltage
10% of rated
voltage
5
6.5
42
28
3.75
.5
9
11.7
135
90
6.75
.9
12
15.6
240
160
9.00
1.2
24
31.2
960
640
18.00
2.4
48
62.4
3840
2560
36.00
4.8
110
140.3
20167
13445
82.50
11.0
Coil Power
W
Operate Time
ms
Release Time
ms
.60
.90
15
10
Coil Power
VA
Operate Time
ms
Release Time
ms
2VA
15
10
Coil Data AC Parameters*
Coil Voltage
VAC
Coil Resistance
Ω +/- 10%
Pick Up Voltage Release Voltage
VAC (max)
VAC (min)
75% of rated
voltage
30% of rated
voltage
27
9.00
3.6
31.2
120
18.00
7.2
Rated
Max
12
15.6
24
110
143
2360
82.50
33.0
120
156
3040
90.00
36.0
220
286
13490
165.00
66.0
240
312
15320
180.00
72.0
277
360
20210
207.00
83.1
www.citrelay.com
phone - 763.535.2339
Dimensions shown in mm. Dimensions are shown for reference purposes only.
fax - 763.535.2194
page 1
Specifications and availability subject to change without notice.
J115F2
General Data*
Electrical Life @ rated load
100K cycles, average
Mechanical Life
10M cycles, average
Insulation Resistance
1000M Ω min. @ 500VDC initial
Dielectric Strength, Coil to Contact
2500V rms min. @ sea level initial
Contact to Contact
1500V rms min. @ sea level initial
Shock Resistance
200m/s2 for 11 ms
Vibration Resistance
1.50mm double amplitude 10~40Hz
Terminal (Copper Alloy) Strength
10N
Operating Temperature
-55oC to +125oC
Storage Temperature
-55oC to +155oC
Solderability
260oC for 5 s
Weight
35g
*
Values can change due to the switching frequency, desired reliability levels, environmental conditions and in-rush load levels. It is recommended to test actual load conditions for the
application. It is the user’s responsibility to determine the performance suitability for their specific application. The use of any coil voltage less than the rated coil voltage may compromise
the operation of the relay.
Ordering Information
1. Series
J115F2
1C
12VDC
S
.9
J115F2
2. Contact Arrangement
1A = SPST N.O.
1B = SPST N.C.
1C = SPDT
3. Profile
Blank = Standard
L = Low profile
4. Coil Voltage
5VDC
9VDC
12VDC
24VDC
48VDC
110VDC
12VAC
24VAC
110VAC
120VAC
220VAC
240VAC
277VAC
5. Sealing Option
S = Sealed (standard)
N = No cover
6. Coil Power
.9 = .9W
.6 = .6W
Blank = 2VA (AC Coil)
7. Contact Material
Blank = AgSnO2
U = AgSnO2In2O3
page 2
www.citrelay.com
phone - 763.535.2339
Dimensions shown in mm. Dimensions are shown for reference purposes only.
fax - 763.535.2194
Specifications and availability subject to change without notice.
J115F2
Dimensions
Units = mm
Blank = Standard Profile
L = Low Profile
N = No Cover
Schematics & PC Layouts
Bottom Views
1A
1B
www.citrelay.com
phone - 763.535.2339
Dimensions shown in mm. Dimensions are shown for reference purposes only.
1C
fax - 763.535.2194
page 3
Specifications and availability subject to change without notice.
Similar pages