DATA SHEET AS195-306LF: PHEMT GaAs IC High-Power SP5T Switch 0.1 to 2 GHz AN T Applications 2G/3G cellular infrastructure V5 GND GND CBL Features Five symmetric RF paths Positive voltage control J1 CBL High IP3 Excellent harmonic performance J2 CBL CBL V1 GND V2 GND CBL V4 GND V3 Handles GSM power levels Available in a small, low-profile QFN-16 (4 x 4 mm) package (MSL1 @ 260 °C per JEDEC J-STD-020) J5 J4 200187-001 Skyworks GreenTM products are compliant with all applicable legislation and are halogen-free. For additional information, refer to Skyworks Definition of GreenTM, document number SQ04–0074. J3 CBL Figure 1. Functional Block Diagram and Pinout of the AS195-306LF Description The AS195-306 is a reflective SP5T switch. It is an ideal switch for higher power applications. It can be used for GSM dual-band handset applications where low loss, low current and small size are critical parameters. Figure 1 shows the block diagram and pinout for the AS195-306LF. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 200187D • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • June 7, 2016 1 DATA SHEET • AS195-306LF: PHEMT GAAS IC HIGH-POWER SP5T SWITCH 0.1 TO 2 GHz Electrical and Mechanical Specifications The absolute maximum ratings of the AS195-306LF are shown in Table 2. Recommended operating conditions of the AS195-306LF are provided in Table 3. The electrical specifications are provided in Table 4. Table 5 shows the electrical specifications for nominal operating conditions. Figures 2, 3, and 4 show the typical performance characteristics for the AS195-306. Table 2. AS195-306LF Absolute Maximum Ratings Parameter Minimum Typical RF input power Maximum Units +36 dBm, f > 500 MHz, +27 dBm < 500 MHz, 0/8 V control 100 mW, f ≤ 500 MHz Control voltage –0.2 8 V Operating temperature –40 +85 °C Storage temperature –65 +150 °C ESD HANDLING: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device must be protected at all times from ESD when handling or transporting. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industrystandard ESD handling precautions should be used at all times. Table 3. AS195-306LF Recommended Operating Conditions Parameter Condition Minimum Typical Maximum Units Switching characteristics: Rise, fall On, off Video feedthru IP3 nd rd 2 and 3 harmonics 10/90%, RF 50% CTL to 90/10% RF TRISE = 1 ns, BW = 500 MHz 50 100 50 ηs ηs mV +13 dBm/tone 55 dBm + 34 dBm input 900 MHz –65 dBc 25 °C/W 0 3 V V Thermal resistance Control voltages VLOW VHIGH Control current IDD @ VHIGH = 3 V 200 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 2 June 7, 2016 • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • 200187D μA DATA SHEET • AS195-306LF: PHEMT GAAS IC HIGH-POWER SP5T SWITCH 0.1 TO 2 GHz Table 4. AS195-306LF Electrical Specifications (TA = +25°C, VLOW = 0 V, VHIGH = 3 V, Z0 = 50 Ω, Unless Otherwise Specified) Parameter Symbol Conditions Insertion loss Ant to J1, J2, J3, J4, J5 0.1 to 0.5 GHz 0.5 to 1.0 GHz 1.0 to 2.0 GHz Isolation Ant to J1, J2, J3, J4, J5 0.1 to 0.5 GHz 0.5 to 1.0 GHz 1.0 to 2.0 GHz Min 30 25 21 Max Units 0.5 0.6 1.0 0.7 0.8 1.1 dB dB dB 35 27 23 dB dB dB 1.4:1 1.6:1 0.1 to 1.0 GHz 1.0 to 2.0 GHz VSWR Typ Table 5. AS196-306LF Truth Table1 V1 V2 V3 V4 V5 ANT-J1 ANT-J2 ANT-J3 ANT-J4 ANT-J5 VHIGH 0 0 0 0 Insertion loss Isolation Isolation Isolation Isolation 0 VHIGH 0 0 0 Isolation Insertion loss Isolation Isolation Isolation 0 0 VHIGH 0 0 Isolation Isolation Insertion loss Isolation Isolation 0 0 0 VHIGH 0 Isolation Isolation Isolation Insertion loss Isolation 0 0 0 VHIGH Isolation Isolation Isolation Isolation Insertion loss 1 All other conditions not recommended. “0” = 0 to 0.2 V. “VHIGH” = 2.7 to 5 V. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 200187D • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • June 7, 2016 3 DATA SHEET • AS195-306LF: PHEMT GAAS IC HIGH-POWER SP5T SWITCH 0.1 TO 2 GHz 0 0 -0.2 -5 -10 J4 Isolation (dB) J3 J1 -0.6 J2 -0.8 -1.0 -1.2 -1.4 -1.6 0 0.5 1.0 1.5 2.0 -15 -20 -25 J4 -30 -35 J2 -40 -45 J1 -50 2.5 0 0.5 Frequency (GHz) 1.0 1.5 2.0 Figure 3. Typical Isolation (All Paths) vs Frequency 2.0 1.9 1.8 1.7 VSWR 2.5 Frequency (GHz) Figure 2. Typical Loss (All Paths) vs Frequency J5 1.6 1.5 1.4 J4 1.3 200187-004 J3 1.2 J2 1.1 J1 1.0 0 0.5 1.0 1.5 2.0 2.5 Frequency (GHz) Figure 4. VSWR vs Frequency Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 4 J5 J3 200187-003 J5 -0.4 200187-002 Insertion Loss (dB) Typical Performance Characteristics (Z0 = 50 Ω, Unless Otherwise Specified) June 7, 2016 • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • 200187D DATA SHEET • AS195-306LF: PHEMT GAAS IC HIGH-POWER SP5T SWITCH 0.1 TO 2 GHz Package Dimensions Package and Handling Information The typical part marking for the AS195-306LF is shown in Figure 5. Package dimensions are shown in Figure 6. Instructions on the shipping container label regarding exposure to moisture after the container seal is broken must be followed. Otherwise, problems related to moisture absorption may occur when the part is subjected to high temperature during solder assembly. The AS195-306LF is rated to Moisture Sensitivity Level 3 (MSL3) at 260 C. It can be used for lead or lead-free soldering. For additional information, refer to the Skyworks Application Note, Solder Reflow Information, document number 200164. Care must be taken when attaching this product, whether it is done manually or in a production solder reflow environment. Production quantities of this product are shipped in a standard tape and reel format. For more information, refer to the Discrete Devices and IC Switch/Attenuators Tape and Reel Package Orientation application note. Pin 1 Indicator Skyworks Part Number Lot Code Date Code: Y = Calendar Year WW = Work Week 200187-005 Figure 5. Typical Part Marking Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 200187D • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • June 7, 2016 5 DATA SHEET • AS195-306LF: PHEMT GAAS IC HIGH-POWER SP5T SWITCH 0.1 TO 2 GHz -CSeating Plane -A- (0.2) 4.00 0.02 +0.03 –0.02 -B- Pin 1 Indicator Exposed Pad 2.15 +0.1 –0.15 (1.075) Option B Pin 1 Indicator Option A Pin 1 Indicator 2.15 +0.1 –0.15 4.00 (1.075) 2X 0.20 Min 16X 0.15 C Scale: 10X 2X Detail B 0.9 ± 0.1 0.15 C 0.10 C R0.12 Typ 0.08 C 16X Scale: 10X R0.20 Pin 1 Indicator 0.18 4 0.345 0.18 0.55 ± 0.1 0.345 (0.325) 0.30 ± 0.05 0.10 C A B 0.65 Detail B Scale: 20X Even terminal side Option A Pin 1 Indicator Scale: 10X Option B Pin 1 Indicator Scale: 20X Detail C Scale: 40X 16 Places Notes: 1. All measurements are in millimeters. 2. Dimensions and tolerances according to ASME Y14.5M-1994. 3. Coplanarity applies to the exposed heat sink slug as well as the terminals. 4. Plating requirement per source control drawing (SCD) 2504. 5. Package may have Option A or Option B pin 1 indicator. 200187-006 Figure 6. AS195-306LF Package Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 6 June 7, 2016 • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • 200187D DATA SHEET • AS195-306LF: PHEMT GAAS IC HIGH-POWER SP5T SWITCH 0.1 TO 2 GHz Ordering Information Model Name AS195-306LF: PHEMT GaAs IC High-Power SP5T Switch 0.1 to 2 GHZ Manufacturing Part Number AS195-306LF Copyright © 2002-2007, 2016 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 200187D • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • June 7, 2016 7