P-DUKE FEC30-24S3P3 30 watts maximum output power Datasheet

FEATURES
• 30 WATTS MAXIMUM OUTPUT POWER
• OUTPUT CURRENT UP TO 6A
• STANDARD 2.0 X 1.6 X 0.4 INCH PACKAGE
• HIGH EFFICIENCY UP TO 90%
• 2:1 WIDE INPUT VOLTAGE RANGE
• SIX-SIDED CONTINUOUS SHIELD
• FIXED SWITCHING FREQUENCY
• OFFER SINGLE AND DUAL OUTPUT
• CE MARK MEETS 2006/95/EC, 93/68/EEC AND 2004/108/EC
• UL60950-1, EN60950-1 AND IEC60950-1 LICENSED
• ISO9001 CERTIFIED MANUFACTURING FACILITIES
• COMPLIANT TO RoHS EU DIRECTIVE 2002/95/EC
APPLICATIONS
Wireless Network
Telecom/Datacom
Industry Control System
Measurement Equipment
Semiconductor Equipment
DESCRIPTION
The FEC30 series offer 30 Watts of output power from a 2 x 1.6 x 0.4 inch
package. The FEC30 series with 2:1 wide input voltage of 9-18VDC,
18-36VDC and 36-75VDC and features 1600VDC of isolation,
short-circuit and over-voltage protection.
T E C H N I C A L S P E C I F I C AT I O N
All specifications are typical at nominal input, full load and 25ºC otherwise noted
OUTPUT SPECIFICATIONS
INPUT SPECIFICATIONS
Output power
30 Watts, max.
Voltage accuracy
Full load and nominal Vin Single/Dual
± 1%
Minimum load
0%
Voltage adjustability
± 10%
Line regulation
LL to HL at Full Load
Load regulation
No Load to Full Load
Single
Dual
Single
Dual
± 0.2%
± 0.5%
± 0.5%
± 1%
Cross regulation (Dual) Asymmetrical load 25% / 100% FL
Ripple and noise
± 5%
20MHz bandwidth
(Measured with a 0.1μF/50V MLCC)
See table
±0.02% / ºC, max.
Temperature coefficient
Transient response recovery time
25% load step change
1.5V output
1.8V output
2.5V output
Over voltage protection
3.3V output
Zener diode clamp
5V output
12V output
15V output
Over load protection
% of FL at nominal input
Short circuit protection
300μS
3.9VDC
3.9VDC
3.9VDC
3.9VDC
6.2VDC
15VDC
18VDC
150%, max.
Hiccup, automatics recovery
GENERAL SPECIFICATIONS
See table
Input to Output
Input (Output) to Case
1600VDC, min.
9
Isolation resistance
10 ohms, min.
Isolation capacitance
1000pF, max.
Switching frequency
300KHz, typ.
Approvals and standard
IEC60950-1, UL60950-1, EN60950-1
Case material
Nickel-coated copper
Base material
FR4 PCB
Potting material
Dimensions
Epoxy (UL94-V0)
2.00 X 1.60 X 0.40 Inch
(50.8 X 40.6 X 10.2 mm)
Weight
MTBF (Note 1)
12V nominal input
24V nominal input
48V nominal input
9 – 18VDC
18 – 36VDC
36 – 75VDC
L-C type
36VDC
50VDC
100VDC
Input filter
12V input
24V input
48V input
Nominal Vin and full
Input reflected ripple current
30mAp-p
load
Nominal Vin and
Power up
25mS, typ.
Start up time
constant resistive load Remote ON/OFF
25mS, typ.
12V input
9VDC
Start-up voltage
24V input
17.8VDC
48V input
36VDC
12V input
8VDC
Shutdown voltage
24V input
16VDC
48V input
33VDC
Remote ON/OFF (Note 6)
(Positive logic)
DC-DC ON
Open or 3.0V < Vr < 12V
DC-DC OFF
Short or 0V < Vr < 1.2V
Input current of remote control pin Nominal Vin
-0.5mA ~ 0.5mA
Remote off state input current
Nominal Vin
2.5mA
Input surge voltage
100mS max
ENVIRONMENTAL SPECIFICATIONS
Operating ambient temperature
-40ºC ~ +85ºC (with derating)
Maximum case temperature
100ºC
Storage temperature range
Efficiency
Isolation voltage
Input voltage range
48g (1.69oz)
BELLCORE TR-NWT-000332
MIL-HDBK-217F
6
1.316 x 10 hrs
5
3.465 x 10 hrs
-55ºC ~ +105ºC
Over temperature protection
115ºC, typ
Nature convection
Thermal impedance (Note 7) Nature convection with
heat-sink
Thermal shock
Vibration
10ºC/Watt
8.24ºC/Watt
MIL-STD-810F
MIL-STD-810F
Relative humidity
5% to 95% RH
EMC CHARACTERISTICS
EMI (Note 8)
EN55022
Class A
Air ± 8KV
Perf. Criteria B
Contact ± 6KV
ESD
EN61000-4-2
Radiated immunity
EN61000-4-3
10 V/m Perf. Criteria A
Fast transient (Note 9) EN61000-4-4
± 2KV Perf. Criteria B
Surge (Note 9)
EN61000-4-5
± 1KV Perf. Criteria B
Conducted immunity
EN61000-4-6
10 Vr.m.s Perf. Criteria A
Page 1 of 3
Issued Date:2008/05/21
Output Current
Output
Voltage Min. load
Full load
Model
Number
Input
Range
FEC30-12S1P5
FEC30-12S1P8
FEC30-12S2P5
FEC30-12S3P3
FEC30-12S05
FEC30-12S12
FEC30-12S15
FEC30-12D12
FEC30-12D15
FEC30-24S1P5
FEC30-24S1P8
FEC30-24S2P5
FEC30-24S3P3
FEC30-24S05
FEC30-24S12
FEC30-24S15
FEC30-24D12
FEC30-24D15
FEC30-48S1P5
FEC30-48S1P8
FEC30-48S2P5
FEC30-48S3P3
FEC30-48S05
FEC30-48S12
FEC30-48S15
FEC30-48D12
FEC30-48D15
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
1.5 VDC
1.8 VDC
2.5 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
±12 VDC
±15 VDC
1.5 VDC
1.8 VDC
2.5 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
±12 VDC
±15 VDC
1.5 VDC
1.8 VDC
2.5 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
±12 VDC
±15 VDC
6000mA
6000mA
6000mA
6000mA
6000mA
2500mA
2000mA
±1250mA
±1000mA
6000mA
6000mA
6000mA
6000mA
6000mA
2500mA
2000mA
±1250mA
±1000mA
6000mA
6000mA
6000mA
6000mA
6000mA
2500mA
2000mA
±1250mA
±1000mA
Output (4)
Input Current
Eff (4) Capacitor (5)
(3)
(2)
(%)
Load max
Ripple & Noise No load
Full load
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
75mVp-p
75mVp-p
100mVp-p
100mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
75mVp-p
75mVp-p
100mVp-p
100mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
75mVp-p
75mVp-p
100mVp-p
100mVp-p
100mA
100mA
110mA
115mA
95mA
170mA
210mA
60mA
40mA
50mA
35mA
45mA
50mA
50mA
80mA
90mA
30mA
30mA
20mA
20mA
25mA
30mA
35mA
35mA
55mA
20mA
20mA
1014mA
1169mA
1582mA
2037mA
3012mA
2976mA
2976mA
3012mA
3012mA
493mA
580mA
780mA
1010mA
1490mA
1470mA
1470mA
1488mA
1488mA
244mA
290mA
390mA
500mA
740mA
730mA
730mA
744mA
744mA
78
81
83
85
87
88
88
87
87
80
82
84
86
88
89
89
88
88
81
83
85
87
89
90
90
88
88
85800μF
65000μF
33000μF
19500μF
10200μF
3240μF
1100μF
±1020μF
±675μF
85800μF
65000μF
33000μF
19500μF
10200μF
3300μF
1100μF
±1020μF
±675μF
85800μF
65000μF
33000μF
19500μF
10200μF
3300μF
1100μF
±1020μF
±675μF
Note
FEC30-48S05 Derating Curve
120
OUTPUT POWER(%)
OUTPUT POWER (%)
1. BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at 40ºC.
MIL-HDBK-217F Notice2 @Ta=25 ºC, Full load(Ground, Benign, controlled environment).
2. Maximum value at nominal input voltage and full load.
3. Typical value at nominal input voltage and no load.
4. Typical value at nominal input voltage and full load.
5. Test by minimum Vin and constant resistive load.
6. The ON/OFF control pin voltage is referenced to -Vin.
7. Heat sink is optional and P/N: 7G-0011C-F.
8. The FEC30 series can meet EN55022 Class A with parallel an external capacitor to the input pins.
Recommend: 12Vin : 6.8μF/50V 1812 MLCC .
24Vin : 6.8μF/50V 1812 MLCC .
48Vin : 2.2μF/100V 1812 MLCC.
9. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220μF/100V, ESR 48mΩ.
100
80
60
40
20
0
-40
-20
0
20
40
60
62.9
80
100
7) Curve
FEC30-48S05 (Note
Derating
With Heatsink (Note 4 )
120
100
80
60
40
20
0
120
-40
-20
0
AMBIENT TEMPERATURE(℃)
FEC30-48S05
Efficiency VS Input Voltage
EFFICIENCY(%)
EFFICIENCY(%)
92
90
88
86
84
82
80
36
40
44
48
52
56
60
INPUT VOLTAGE (V)
64
68
20
60 69.4 80
40
100
120
AMBIENT TEMPERATURE(℃)
72
95
90
85
80
75
70
65
60
55
50
45
FEC30-48S05
Efficiency VS Output Load
10
20
30
40
50
60
70
80
90
100
OUTPUT LOAD (% of Full Load)
Page 2 of 3
Issued Date:2008/05/21
Recommended Filter for EN55022 Class B Compliance
The components used in the above figure, together with the
manufacturers’ part numbers for these components, are as
1. All dimensions in Inches (mm)
Tolerance: X.XX±0.02 (X.X±0.5)
X.XXX±0.01 (X.XX±0.25)
2. Pin pitch tolerance ±0.01(0.25)
3. Pin dimension tolerance ±0.004 (0.1)
follows:
C1
C2
C3
C4
C5 & C6
FEC3012xxx
4.7μF/50V
1812 MLCC
N/A
4.7μF/50V
1812 MLCC
N/A
1000pF/2KV
MLCC
FEC3024xxx
6.8μF/50V
1812 MLCC
N/A
6.8μF/50V
1812 MLCC
N/A
1000pF/2KV
MLCC
FEC3048xxx
2.2μF/100V 2.2μF/100V 2.2μF/100V 2.2uF/100V 1000pF/2KV
1812 MLCC 1812 MLCC 1812 MLCC 1812 MLCC
MLCC
PIN CONNECTION
PIN
SINGLE
DUAL
1
2
4
5
6
7
8
+ INPUT
- INPUT
CTRL
NO PIN
+ OUTPUT
- OUTPUT
TRIM
+ INPUT
- INPUT
CTRL
+ OUTPUT
COMMON
- OUTPUT
TRIM
L1
450μH
Common
Choke
PMT-048
450μH
Common
Choke
PMT-048
450μH
Common
Choke
PMT-048
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by using the method
shown below. ( ) for dual output trim
TRIM UP
TRIM DOWN
7(7)
8(8)
RU
8(8)
RD
6(5)
Recommended EN55022 Class B Filter Circuit Layout
Page 3 of 3
Issued Date:2008/05/21
Similar pages