Murata CPCI200D-3 200w 3ux4hp dc/dc compactpci power supply Datasheet

cPCI200D Series
200W 3Ux4HP DC/DC CompactPCI™ Power Supply
SELECTION GUIDE
Model Number
Output Current
Power
5V
3.3V
12V
-12V
IPMI
Production Status
cPCI200D-1
180W
18A1
27A
4A1
4A1
No
Consult Factory
No
cPCI200D-2
225W
27A
27A2
4A2
4A2
No
Consult Factory
No
cPCI200D-3
180W
1
18A
27A
4A
1
1
Yes
Consult Factory
No
cPCI200D-4
225W
27A
27A2
4A2
4A2
Yes
Consult Factory
No
1
1
1
4A
FEATURES
cPCI200D-1C
180W
18A
27A
4A
4A
No
Active
Yes
3Ux4HP Package
cPCI200D-2C
225W
27A
27A2
4A2
4A2
No
Active
Yes
cPCI200D-3C
180W
1
18A
27A
4A
1
1
Yes
Active
Yes
cPCI200D-4C
225W
27A
27A2
4A2
4A2
Yes
Active
Yes
180/225W Power at 0-50ºC
PICMG 2.11 Compliant
RoHS Compliant
INPUT CHARACTERISTICS
Wide range 36-72Vdc Input Range
Parameter
IPMI Option
Input Operating Voltage
47-pin I/O Connector
Input Voltage Withstand
70% Efficiency
Inrush Current
Conditions
Min
Hot-Swap Capable
DESCRIPTION
The cPCI200 is a family of high-reliability, 200W,
3Ux4HP CompactPCI™ power supplies operating
from a nominal 48Vdc input. The use of our patented V-Series topology yields high efficiency which
consequently permits packaging of this product in a
compact, single card slot format (4HP).
4A
Max
Units
36
72
Vdc
34
75
Vdc
36Vdc input
20
Apk
72Vdc input
40
Apk
OUTPUT CHARACTERISTICS
Parameter
Conditions
Output Voltage Regulation3
Min
Typ
-2
+4
%Vnom
-10
+10
%Vnom
20MHz bandwidth
ORing diodes and current sharing allow the cPCI200
to be operated in N+n parallel-redundant configurations. Available with an IPMI interface option, the
cPCI200 was designed for hot-swap, redundant
configurations to support high-availability (HA)
telecom applications.
PARD (V3 & V4)
20MHz bandwidth
With a widerange input of 36-72Vdc, safety agency
approvals to UL60950 and EN60950, EMI compliance
to ETSI and Telcordia standards, the cPCI200 was
designed with globally-deployed systems in mind.
Additional features include remote sense compensation, unit enable control (EN#), output inhibit control (INH#), output fault signal (FAL#), and thermal
warning signal (DEG#). LEDs are provided for visual
indication of input power presence, output inhibit,
and output fault condition.
Transient Response
Output Power, CPCI200D-2 & -4
Over-Voltage Protection
120
Current Share Tolerance
mVp-p
180
mVp-p
0
180
W
0
90
W
50ºC, 300lfm airflow
0
225
W
70ºC, 300lfm airflow
0
110
W
ΔV, 50% load step
±10
%Vnom
Settling time
500
μsec
135
%Vnom
125
V1 & V2
500
mA
50
mV
V1&V2; full load
Pri-Sec
Isolation
%/ºC
50
70ºC, 300lfm airflow
Minimum Load4
5
0.02
50ºC, 300lfm airflow
V1 & V2
Remote Sense Compensation
Units
Outputs V1 & V2
Temperature Coefficient
Output Power, CPCI200D-1 & -3
Max
Outputs V3 &V4
PARD (V1 & V2)
The 4HP package and complement of global
safety agency approvals provide for an advanced,
high-density, high-efficiency power solution for
your CompactPCI requirements.
Typ
±10
%Itot
1.5
kVac
Pri-Chassis
1.5
kVac
Sec-Chassis
500
Vac
Notes:
1. Maximum combined power from outputs V1, V3, & V4 not to exceed 90W.
2. Maximum combined power from outputs V2, V3, & V4 not to exceed 90W.
3. Total regulation includes line, load, and cross regulation.
4. Minimum load requirement of 500mA is required on V1 for 180W models and on V2 for 225W models.
5. Current share circuit is primary-referenced.
For full details go to
www.murata-ps.com/rohs
ISO9001
CERTIFIED
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
cPCI200D Series.B01 Page 1 of 5
cPCI200D Series
200W 3Ux4HP DC/DC CompactPCI™ Power Supply
GENERAL CHARACTERISTICS
Parameter
Efficiency
Conditions
Min
48Vdc input, full load
Max
Units
440
kHz
70
Switching Frequency
Weight
Typ
400
Unpackaged
%
420
636
g
PROTECTION
Parameter
Thermal Shutdown
Conditions/Response
Inception
Min
Automatic recovery upon restoration to operational temperatures
Typ
Max
Units
100
ºC
Input Protection
Internal line fuse, all models, Littlefuse R251010 or equivalent
Over-Voltage Protection
V1 & V2
Output Overload Protection
Outputs are individually protected against overloads and indefinite short circuit with automatic recovery upon removal of the fault condition.
Overload response for all outputs is constant-current mode.
Hot-Swap Capability
Design Verification Testing (DVT) confirms that voltage excursions on the output buses resulting from insertion/extraction events do not exceed
the specified maximum of 10%. However, routing of power and signal lines in the mating backplane is critical to minimization of such excursions. In addition, performance can be critically affected by load characteristics including resistance, negative resistance, and reactive components. While the control loop responses have been designed for optimum hot-swap performance over a wide range of characteristics, there
may be instances where the voltage excursions exceed published specifications. In such cases, the control loop responses can be modified to
perform optimally.
Output Fault Isolation
Output isolation devices are present in all outputs to isolate faults within a failed power supply.
Remote Sense Lead Protection
Outputs V1 & V2 are capable of compensating for >50mV of line drop. Unit automatically reverts to local sensing in the event that the sense
lines are opened for any reason. Unit is also protected against reversed or shorted sense leads.
125
10
A
135
%Vnom
STATUS & CONTROL SIGNALS & INDICATORS
Name
Description
Enable (EN#)
Short pin on connector will enable the outputs when the mating pin is grounded. Supply will not power up until this pin is
engaged to its mate in the backplane. Unit output will be inhibited as pin is disengaged from the mating connector.
Output Inhibit (INH#)
Secondary referenced; active low, TTL compatible. Logic “0” or short circuit to output return inhibits all outputs.
Output Fault (FAL#)
Secondary referenced. Open collector signal denotes that one of the output voltages has fallen below the lower regulation limit.
Remote Sense (RS+, RS-)
Connection of the sense leads across the load at the desired point of regulation will compensate for voltage distribution drops up
to 50mV between the output terminals of the power supply and the point of connection. The unit reverts to local sensing if the
sense lines are opened for any reason. The output is protected against shorted or open leads. Applies to outputs V1 & V2.
Thermal Warning (DEG#)
Secondary referenced. Open collector denotes a thermal warning; nominally, 10ºC prior to thermal shutdown.
Fault Indicator LED
An LED will illuminate red if the output voltages are not within specification, coincident with assertion of the FAL# signal.
Power Present Indicator LED
A green LED will be illuminated when the input voltage is present and above the minimum requirement.
Output Inhibit Indicator LED
An amber LED will be illuminated when the output is inhibited.
IPMI Interface Option
An I2C interface board is available as a factory-installed option to provide an IPMI interface to the SMBus. Status functions
include output voltage and current levels as well as the DEG# warning. Output inhibit control can also be toggled via software
command. See application note ACAN-02 for the satellite controller specification, ACAN-03 for the firmware update procedure,
and ACAN-04 for the test procedure.
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
cPCI200D Series.B01 Page 2 of 5
cPCI200D Series
200W 3Ux4HP DC/DC CompactPCI™ Power Supply
ENVIRONMENTAL CHARACTERISTICS
Parameter
Conditions
Min
Max
Units
AmbientOperatingTemperature
De-rate output power linearly above 50ºC to half-power at 70ºC.
0
70
ºC
-20
85
Ambient Storage Temperature
Cooling Airflow
Humidity
Altitude
Typ
ºC
50ºC ambient, full load
300
lfm
Operating; non-condensing
10
90
%
Storage; non-condensing
5
90
%
Operating. De-rate operating ambient temperature by 2Cº per 1000ft above 5000ft.
-200
10000
ft
Storage
-200
50000
ft
ELECTROMAGNETIC COMPATIBILITY (EMC)
Characteristic
Compliance
EN 300 386
Conducted Emissions
NEBS GR-1089
CERTIFICATIONS
Agency/Characteristic
Standard
UL
UL1950
CSA
CSA950 (per cUL)
VDE
EN60950
CE
LVD Directive; self-certified
RoHS
EN Directive 2002/95/EC; self-certified; see Selection Guide table for specific model
compliance
SELV
Self-certified
Vibration
MIL-STD-810D, Method 514.3, Procedure I; self-certified
Shock
MIL-STD-810D, Method 516.3, Procedure I; self-certified
IPMI/IPMB POWER SUPPLY SATELLITE CONTROLLER FEATURES
Complies with IPMI V1.5 Rev 1.1 and IPMB V1.0
Complies with PICMG 2.9 (CompactPCI Systems Management Specification)
8 analog inputs configured for monitoring voltages and currents on power supply outputs V1 - V4
Monitors the thermal sensor (DEG#) and fault signal (FAL#)
Output inhibit can be controlled by IPMI commands
Self Test with LED indicator (can be read and overridden by IPMI commands)
6 programmable thresholds on each analog sensor; each threshold on each sensor can be enabled to generate event messages if that threshold is crossed
Thermal sensor can be enabled to generate event messages
Responds to all mandatory IPMI commands and numerous optional commands as indicated in the functional specification
Firmware can be upgraded via the IPMB bus
Includes Device SDR’s (Sensor Data Records) – These specify the type of sensor for each input (voltage, current, temperature, etc.) as well as the conversion formulas for raw
ADC data to voltages, currents, etc.
Includes FRU data such as model number, serial number and firmware creation date
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
cPCI200D Series.B01 Page 3 of 5
cPCI200D Series
200W 3Ux4HP DC/DC CompactPCI™ Power Supply
PACKAGE SPECIFICATIONS (PIN ASSIGMENTS)
PIN ASSIGNMENT: Pin assignment consistent with PICMG™ 2.11R1.0
specification. The table below details the PICMG™ assignment.
Pin #1
Staging2
Signal Name
Description
1-4
M
V1
V1 Output
5-12
M
RTN
V1 and V2 Return
13-18
M
V2
V2 Output
19
M
RTN
V3 Return
20
M
V3
V3 Output
21
M
V4
V4 Output
22
M
RTN
Signal Return
23
M
RESERVED
Reserved
24
M
RTN
V4 Return
25
M
GA0
Geographic Address Bit 0
26
M
RESERVED
Reserved
27
S
EN#
Enable
28
M
GA1
Geographic Address Bit 1
29
M
V1ADJ
V1 Adjust3
30
M
V1 SENSE
V1 Remote Sense
31
M
GA2
Geographic Address Bit 2
32
M
V2ADJ
V2 Adjust3
33
M
V2 SENSE
V2 Remote Sense
34
M
S RTN
Sense Return
35
M
V1 SHARE
V1 Current Share3
36
M
V3 SENSE
V3 Remote Sense
37
M
IPMB SCL
IPMB Serial Clock Line
38
M
DEG#
Degrade Signal
39
M
INH#
Inhibit
40
M
IPMB SDA
IPMB Serial Data Line
41
M
V2 SHARE
V2 Current Share3
42
M
FAL#
Fail Signal
43
M
IPMB PWR
IPMB Power Input
44
M
V3 SHARE
V3 Current Share3
45
L
CGND
Chassis Grnd (Safety Grnd)
46
M
ACN/+DC IN
AC Input Neutral/+DC Input
47
M
ACL/-DC IN
AC Input Line/-DC Input
1. Pin numbers correspond to the female backplane connector.
2. Length Pins; S = Short Length Pins (Last Make, First Break) L = Long Length Pin
(First Make, Last Break); M = Medium.
3. These functions are not used in the cPCI200D Series.
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
cPCI200D Series.B01 Page 4 of 5
cPCI200D Series
200W 3Ux4HP DC/DC CompactPCI™ Power Supply
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
POSITRONICS CONNEC
PART NO. PCIH47M400
6.68 [169.58]
6.40 [162.54]
0.1 [2.5]
MIN
MODEL NO. cPCI200DC
PIN 21
3.937
-0.3
[100.00 ] +0.0
+.000
-.012
PIN 1
0.1 [2.5]
MIN
AIRFLOW
MECHANICAL
Shock: MIL-STD-810d, Method 516.3, Procedure 1.
Vibration: MIL-STD-810d, Method 514.3, Procedure 1.
Dimensions: 3U x 4HP x 160mm (see Mechanical above)
EMC & SAFETY
EMI:
NEBS Compliant to GR1089 conducted emissions limit
ETSI Compliant to ETS 300-386 conducted emissions
limit
Safety Agency Ratings 180 Watt 225 Watt
Input Voltage:
36-72 VDC 36-72 VDC
Input Current:
7A
9A
Input Power:
260W
320W
Agency Approvals: UL1950/CSA950, EN60950, CE Mark (Low Voltage
Directive).
USA:
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: [email protected] ISO 9001 and 14001 REGISTERED
10/30/08
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2008 Murata Power Solutions, Inc.
www.murata-ps.com
Mansfield (MA), Tel: (508) 339-3000, email: [email protected]
Canada:
Toronto, Tel: (866) 740-1232, email: [email protected]
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected]
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected]
Germany:
München, Tel: +49 (0)89-544334-0, email: [email protected]
Japan:
Tokyo, Tel: 3-3779-1031, email: [email protected]
Osaka, Tel: 6-6354-2025, email: [email protected]
China:
Shanghai, Tel: +86 215 027 3678, email: [email protected]
Guangzhou, Tel: +86 208 221 8066, email: [email protected]
Singapore:
Parkway Centre, Tel: +65 6348 9096, email: [email protected]
Technical enquiries email: [email protected], tel: +1 508 339 3000
cPCI200D Series.B01 Page 5 of 5