Honeywell HMR3000-D21-485 Digital compass module Datasheet

SENSOR PRODUCTS
Digital Compass Module
APPLICATIONS
Oceanographic
– Marine Compassing
– Positioning of Buoys,
Underwater Structures
HMR3000
Drilling
– Down Hole and Directional
Attitude Reference
Heading
– Navigation of Unmanned
Vehicles
– Avionic Compassing
Integration with GPS
– Dead Reckoning
Satellite Antenna Positioning
E
lectronic compass module that
provides heading, pitch and roll
output for navigation and guidance systems. Honeywell’s
solid state magnetoresistive
sensors make this strapdown
compass both rugged and reliable. This compass provides
fast response time up to 20
Hertz and high heading accuracy of 0.5° with 0.1° resolution.
Laser Range Finders
– Surveying Applications
FEATURES AND BENEFITS
Fast Response Time
Built with solid state magnetic sensors and no moving parts improves response time,
allowing faster updates compared to gimballed fluxgates.
Small Size
Available as a circuit board 1.2 x 2.95 inches, weighing less than one ounce, or in an
aluminum enclosure.
Low Power
Operates with less than 35 mA, allowing for long operation with a battery.
High Accuracy
Accuracy better than 0.5° with 0.1° resolution for critical positioning applications.
Wide Tilt Range
Tilt range of ±40° for both the roll and pitch allows operation for most applications.
Hard Iron Compensation
Calibration routines to compensate for distortion due to nearby ferrous objects and
stray fields, such as vehicles.
User Configurable Features
User settings of baud rate, update rate, output format, units, filter settings, deviation
angles, alarms and warnings are stored internally in non-volitile memory.
HMR3000
SENSOR PRODUCTS
INTERFACE SIGNAL DESCRIPTIONS
(HPR, RCD and CCD), and an ASCII heading output for
a digital display. HDG, HDT and HPR are the most
commonly used sentences; the formats are given below.
Communication
HMR3000 communicates with an external host via RS232 or RS-485 electrical standard through simple ASCII
character strings. ASCII characters are transmitted and
received using 1 Start bit, 8 Data bits, (LSB first, MSB
always 0), no parity, and 1 Stop bit. Baud rate is user
configurable to 1200, 2400, 4800, 9600, 19,200 or
38,400. HMR3000 responds to all valid inputs received
with correct checksum value.
$HCHDG, Heading, Deviation, Variation
$HCHDG,85.5,0.0,E,0.0,E*77
$HCHDT, Heading, True
$HCHDT,271.1,T*2C
$PTNTHPR, Heading, Pitch and Roll
$PTNTHPR, Heading,Heading Status,Pitch,Pitch
Status,Roll,Roll Status*hh<cr><lf>
$PTNTHPR,85.9,N,-0.9,N,0.8,N*2C
Compass Output
HMR3000 can output three NMEA standard sentences,
(HDG, HDT and XDR), three proprietary sentences
The table shows pin assignments for the 9-pin D-shell connector. Power input can be either regulated 5V dc or
unregulated 6V to 15V. Only one of the two power pins (9 or 8) should be connected in a given installation.
Name
In/Out Pin Description
Typ
Min (1) Max (1) Units
TxD / B
Out
2
RS-232 transmit out / RS-485
—
-18
18
V dc
RxD / A
In
3
RS-232 receive in / RS-485
—
-18
18
V dc
GND
In
5
Power and signal common
—
6-15V
In
9
Unregulated power input
6 – 15
0
30
V dc
5V
In
8
Regulated power input
5 ± 5%
0
7.5
V dc
Oper / Calib (2)
In
1
Operate / Calibrate (3) input (open = Operate)
0– 5
-20
20
V dc
Run / Stop (2)
In
6
Run / Stop (3) input (open = Run)
0– 5
-20
20
V dc
Ready / Sleep (2)
In
4
Ready / Sleep (3) input (open = Ready)
0– 5
-20
20
V dc
Cont / Reset (2)
In
7
Continue / Reset (3) input (open = Continue)
0– 5
-20
14
V dc
(1) Absolute maximum ratings.
(2) Sink current requirement; 200 (Typ) 400 (Max) µA.
(3) Open input = high logic state.
2
HMR3000
SENSOR PRODUCTS
SPECIFICATIONS
Parameter
Value
Comments
Heading
Accuracy (1)
< 0.5° RMS (2)
< 1.5° RMS
Repeatability (3) (4)
± 0.3°
Resolution
0.1°
Units
degrees / mils
Dip < 50° , Tilt <20° *
Dip < 75° , Tilt <20° *
User selectable
Pitch and Roll
Range
± 40°
Accuracy
± 0.4°
± 0.6°
Repeatability (3) (4)
± 0.2°
Tilt < 20°
Tilt > 20° *
Resolution
0.1°
Units
degree/ mils
User selectable
Magnetic Field (3)
Dynamic Range
± 1.0 Gauss max
Resolution
1 mGauss
Supply Voltage
5.0 Vdc regulated
6 - 15 Vdc unregulated
Power
35 mA @ 6 Vdc
13 mA
2.0 mA
Serial
RS-232
RS-485
Baud Rate
1200 to 38400 bps
Standard
NMEA 0183
Update Modes
Continuous
Strobed
Weight
0.75 oz (22 g)
3.25 oz (92 g)
Circuit card only
Housed
Dimensions
1.2 x 2.95 x 0.760
1.5 x 4.2 x 0.88
Circuit card
Housed compass
± 0.5 Gauss range
Electrical (4)
Normal operation
STOP Mode
SLEEP Mode
Interface
Half Duplex
1/min to 20 Hz per sentence
selectable averaging
Physical (4)
Environment (5)
Operating Temp
-20 to 70° C
Storage Temperature
-35 to 100° C
Shock
30 inch drop
MIL-STD-810E; TM 516.4
Vibration
20 - 2000 Hz
Random 2 hrs/axis
MIL-STD-810E; TM 514.4
PCB
IPC 6012
Assembly
IPC 610
Manufacturing
Class II or better
4.Typical
5.Meet or exceed.
* Device orientation not to exceed 75°
during operation or storage—may cause
temporary loss of accuracy.
1.Heading accuracy assumes the Earth’s
magnetic field is only disturbed by hard iron
fields, and has been compensated through
calibration.
2.Calculated values.
3.Guaranteed by characterization or design.
3
HMR3000
SENSOR PRODUCTS
SPECIFICATIONS
HMR3000 CONNECTION DIAGRAM—COMPUTER RS232 TO HMR3000
RS-232 computer pins
HMR3000 pins
2
3
5
9
RX 2
TX 3
GND 5
RS-232 computer pins
TX
RX
GND
V+
5 Vdc Reg.
Regulated voltage
source
Unregulated Supply
4.200 (10.67)
Z
0.188
(0.46)
Regulated Supply
AA
A
AA
A
AA
A
A
AA
A
AA
0.812
(2.06
)
Φ 0.150 (0.38)
S/N 300062
RS
232
485
Y
Pitch
Roll
1.500 (3.81)
HMR3000
Compass Module
Forward
X
3.250 (8.26)
0.188
(0.46)
2 TX
3 RX
5 GND
8 V+
RX 2
TX 3
GND 5
6-15 Vdc
ac adapter
HMR3000 pins
inches
(centimeters)
0.062
0.062 (
(0.16)
0.16)
ORDERING INFORMATION
Type
RS-232 to RS-485
B & B Electronics #485TBLED
SD Control
Echo Off
RS-232
TD
RD
GD
2 RD
3 TD
7 GD
Shield
TD(A)
TD(B)
RD(A)
RD(B)
GND
+12V
VAC
1
2
3
4
5
6
7
+12VDC
Output
Enclosure
HMR3000-Demo-232* ..... RS232
RS-485
HMR3000-D00-232 ......... RS232 ....... None
HMR3000-D21-232 ......... RS232 ....... Extended Base
(B)
(A)
2
3
RS-485
Gnd
Pwr
5
9
Gnd
+12VDC
DB9 socket
connector
HMR3000-D00-485 ......... RS485 ....... None
HMR3000-D21-485 ......... RS485 ....... Extended Base
*Development Kit includes one module in aluminum enclosure,
cabling with power supply, demonstration software for PC running
Windows™ and User’s Manual.
Honeywell reserves the right to make changes to any products or technology herein to improve reliability, function or design. Honeywell does not assume any liability
arising out of the application or use of any product or circuit described herein; neither does it convey any license under its patent rights nor the rights of others.
Solid State Electronics Center
12001 State Highway 55
Plymouth, MN 55441
1-800-323-8295
900204 Rev. B