TECHNICAL DATA SHEET NL2076 Two-Stages Thermoelectric Module RoHS EU Compliant TYPICAL PERFORMANCE VALUES MECHANICAL CHARACTERISTICS Nitrogen (1 ATM) Hot Side Temperature (°C) ∆ Tmax (°C): Qmax (watts): Imax (amps): Vmax (vdc): AC Resistance (ohms): 27 80 44.6 7.2 15.5 1.93 50 90 49.3 7.1 17.2 --- Vacuum (10-5 TORR) Hot Side Temperature (°C) ∆ Tmax (°C): Qmax (watts): Imax (amps): Vmax (vdc): AC Resistance (ohms): 27 87 45.0 7.1 15.5 1.93 50 99 49.9 7.1 17.2 --- ORDERING OPTIONS PRODUCT FEATURES Model Number Description NL2076-01AC NL2076-02AC NL2076-03AC NL2076-04AC NL2076-05AC TEM, Top and Base Metallized Exterior TEM, Base Metallized Exterior TEM, No Metallized Exterior TEM, Base Pre-tinned w/117°C solder TEM, Top & Base Metallized Exterior, 203mm Insulated Wires TEM, No Metallized Exterior, 102mm Au over Ni over Cu Wires, Burn-In Test and Data TEM, No Metallized Exterior, 203mm Insulated Wires TEM, No Metallized Exterior, Lapped, 203mm Insulated Wires NL2076-06AC NL2076-08AC NL2076-09AC Ideal for large temperature differentials (∆T) and large heat pumping application. Rated operating temperature of 130°C. Superior nickel diffusion barriers on elements. High strength for rugged environment. Pre-tinned metallized ceramic surfaces(s) with 117°C solder option available. Burn-in test data option available. Lapped option available. For customer support or general questions please contact a local office or visit our website at www.marlow.com. MI Form 005-0690 Rev. 2 DOC # 102-0495 REV 6 - PAGE 1 OF 3 TECHNICAL DATA SHEET DOC # 102-0495 REV 6 - PAGE 2 OF 3 TECHNICAL DATA SHEET ENVIRONMENT: TYPICAL PERFORMANCE CURVES Nitrogen (1 ATM) -5 Vacuum (10 TORR) For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, consult one of our Applications Engineers. Installation Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional information, please refer to our TEC Installation Guide. Operation Cautions For maximum reliability, storage and operation below 85°C in a non-condensing environment is recommended. To minimize thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method. CONTACT US: For customer support or general questions please contact a local office below or consult our website for distributor information. Marlow Industries, Inc. 10451 Vista Park Road Dallas Texas 75238-1645 214-340-4900 (tel) 214-341-5212 (fax) www.marlow.com Marlow Industries Europe GmbH Brunnenweg 19-21 64331 Weiterstadt Germany Tel.: +49 (0) 6150 5439 - 403 Fax: +49 (0) 6150 5439 - 400 [email protected] II-VI Japan Inc. WBG Marive East 17F 2-6 Nakase, Mihama-ku Chiba-Shi, Chiba 261-7117 Japan 81 43 297 2693 (tel) 81 43 297 3003 (fax) [email protected] www.ii-vi.co.jp II-VI Singapore Pte., Ltd. Blk. 5012, Techplace II #04-07 & 05-07/12, Ang Mo Kio Ave. 5 Singapore 569876 (65) 6481 8215 (tel) (65) 6481 8702 (fax) [email protected] www.ii-vi.com.sg Marlow Industries China, II-VI Technologies Beijing A subsidiary of II-VI Incorporated Rm 202, 1# Lize 2nd Middle Road Wangjing, Chaoyang District Beijing 100102 China 010-64398226 ext 105 (tel) 010-64399315 (fax) [email protected] DOC # 102-0495 REV 6 - PAGE 3 OF 3