Micross MIMMF300S060B 600v 300a fred module rohs compliant Datasheet

MIMMF300S060B
MIMMF300S060B2B
600V 300A FRED Module
RoHS Compliant
PRODUCT FEATURES
Ultrafast Reverse Recovery Time
Soft Reverse Recovery Characteristics
Low Reverse Recovery Loss
Low Forward Voltage
High Surge Current Capability
Low Inductance Package
APPLICATIONS
Inversion Welder
Uninterruptible Power Supply (UPS)
Plating Power Supply
Ultrasonic Cleaner and Welder
Converter & Chopper
Power Factor Correction (PFC) Circuit
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
TC=25°C unless otherwise specified
Test Conditions
Values
Unit
VR
Maximum D.C. Reverse Voltage
600
V
VRRM
Maximum Repetitive Reverse Voltage
600
V
IF(AV)
Average Forward Current
TC=110°C, Per Diode
300
A
TC=120°C, 20KHz, Per Moudle
400
A
IF(RMS)
RMS Forward Current
TC=110°C, Per Diode
420
A
Non-Repetitive Surge
TJ=45°C, t=10ms, 50Hz, Sine
3000
A
Forward Current
TJ=45°C, t=8.3ms, 60Hz, Sine
3200
A
TJ=45°C, t=10ms, 50Hz, Sine
45000
A2s
TJ=45°C, t=8.3ms, 60Hz, Sine
51200
A2s
893
W
IFSM
I2t
I2t (For Fusing)
PD
Power Dissipation
TJ
Junction Temperature
-40 to +150
°C
TSTG
Storage Temperature Range
-40 to +125
°C
Visol
Insulation Test Voltage
AC, t=1min
3000
V
Torque
Module-to-Sink
Recommended(M6)
3~5
N·m
Torque
Module Electrodes
Recommended(M6)
3~5
N·m
RθJC
Thermal Resistance
Junction-to-Case
0.14
°C /W
155
g
Weight
MIMMF300S060B
MIMMF300S060B2B
ELECTRICAL CHARACTERISTICS
Symbol
Parameter
TC=25°C unless otherwise specified
Test Conditions
Min.
Typ.
Max.
Unit
VR=600V
--
--
2
mA
VR=600V, TJ=125°C
--
--
10
mA
IF=300A
--
1.15
1.65
V
IF=300A, TJ=125°C
--
--
1.45
V
IRM
Reverse Leakage Current
VF
Forward Voltage
trr
Reverse Recovery Time
IF=1A, VR=30V, diF/dt=-200A/μs
--
55
--
ns
trr
Reverse Recovery Time
VR=300V, IF=300A
--
150
--
ns
IRRM
Max. Reverse Recovery Current
diF/dt=-200A/μs, TJ=25°C
--
17.5
--
A
trr
Reverse Recovery Time
VR=300V, IF=300A
--
245
--
ns
IRRM
Max. Reverse Recovery Current
diF/dt=-200A/μs, TJ=125°C
--
30
--
A
500
600
500
400
TJ =125°C
trr (ns)
IF (A)
400
300
TJ =25°C
IF=300A
0
1
1.5
2.5
2
VF(V)
Figure1. Forward Voltage Drop vs Forward Current
0.5
400
600
800
1000
diF/dt(A/μs)
Figure2. Reverse Recovery Time vs diF/dt
200
VR=300V
TJ =125°C
10
8
90
IF=600A
IF=300A
60
IF=150A
30
Qrr (μc)
IRRM (A)
0
12
VR=300V
TJ =125°C
120
0
0
IF=600A
100 IF=150A
100
150
300
200
200
0
0
VR=300V
TJ =125°C
6
IF=600A
4
IF=150A
IF=300A
2
400
600
1000
800
diF/dt(A/μs)
Figure3. Reverse Recovery Current vs diF/dt
200
0
0
200
400
600
800
1000
diF/dt(A/μs)
Figure4. Reverse Recovery Charge vs diF/dt
MIMMF300S060B
MIMMF300S060B2B
1.5
1
1.2
-1
10
Kf
ZthJC (K/W)
0.9
trr
IRRM
0.6
0.0
10-3
Qrr
0.3
0
10-2
Duty
0.5
0.2
0.1
0.05
Single Pulse
25
50
100 125 150
75
TJ (°C)
Figure5. Dynamic Parameters vs Junction Temperature
-4
10
-1
10-4
10-3
10-2
10
1
Rectangular Pulse Duration (seconds)
Figure6. Transient Thermal Impedance
Dimensions (mm)
Figure7. Package Outline
Similar pages