Dc FR102 Technical specifications of fast recovery rectifier Datasheet

FR101
DC COMPONENTS CO., LTD.
R
THRU
RECTIFIER SPECIALISTS
FR107
TECHNICAL SPECIFICATIONS OF FAST RECOVERY RECTIFIER
VOLTAGE RANGE - 50 to 1000 Volts
CURRENT - 1.0 Ampere
FEATURES
*
*
*
*
*
*
Fast switching
Low leakage
Low forward voltage drop
High current capability
High surge capability
High reliability
DO-41
MECHANICAL DATA
*
*
*
*
*
Case: Molded plastic
Epoxy: UL 94V-0 rate flame retardant
Lead: MIL-STD-202E, Method 208 guaranteed
Mounting position: Any
Weight: 0.33 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
SYMBOL
FR101
FR102
FR103
FR104
FR105
FR106
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
Volts
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at T A = 75 oC
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC Method)
Maximum Instantaneous Forward Voltage at 1.0A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage T A = 25 oC
IO
1.0
Amps
I FSM
30
Amps
VF
1.3
Volts
5.0
uAmps
100
uAmps
IR
Maximum Full Load Reverse Current Full Cycle
Average, .375*(9.5mm) lead length at T L = 55 oC
Maximum Reverse Recovery Time (Note 1)
trr
Typical Junction Capacitance (Note 2)
CJ
15
T J , T STG
-65 to + 150
Operating and Storage Temperature Range
FR107 UNITS
250
150
500
nSec
pF
0
C
NOTES : 1. Test Conditions: IF = 0.5A, IR = 1.0A, IRR = 0.25A