EPCOS B41827A6336M Aluminum electrolytic capacitor Datasheet

Aluminum electrolytic capacitors
Single-ended capacitors
Series/Type:
B41827, B43827
Date:
December 2010
© EPCOS AG 2010. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
Single-ended capacitors
B41827, B43827
Standard series 85 °C
General-purpose grade capacitors
Applications
General-purpose applications
Semi-professional to professional application range
For filtering, coupling and pulse circuits
Features
Miniaturized dimensions
RoHS-compatible
Useful life of 2000 h at 85 °C
Construction
Radial leads
Charge-discharge proof, polar
Aluminum case with insulating sleeve
Minus pole marking on the insulating sleeve
Case with safety vent from diameter 8 mm
Delivery mode
Bulk
Taped, Ammo pack
Cut (see chapter "Single-ended Taping, packing and lead
configurations, Cut leads (Chapter A)")
Kinked (see chapter "Single-ended Taping, packing and
lead configurations, Kinked leads (Chapter A)")
Refer to chapter "Single-ended capacitors Taping, packing
and lead configurations" for further details.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 39
B41827, B43827
Standard series 85 °C
Specifications and characteristics in brief
Series
Rated voltage VR
Surge voltage VS
Rated capacitance CR
Capacitance tolerance
Dissipation factor
(max.)
(20 °C, 120 Hz)
B41827
B43827
6.3 ... 100 V DC
160 ... 450 V DC
VR ≤ 250 V DC: 1.15 VR (at room temperature)
VR > 250 V DC: 1.1 VR (at room temperature)
0.47 ... 22000 µF
0.47 ... 330 µF
±20% M
±20% M
For capacitance higher than 1000 µF add 0.02 for every increase of
1000 µF.
VR
6.3
(V DC)
tan δ
10
16
25
or 3 µA, whichever is greater
Useful life
85 °C; VR; IAC,R
> 2000 h
∆C/C
tan δ
Ileak
50
63
100 160 350 450
...
...
250 400
0.22 0.20 0.16 0.14 0.12 0.10 0.09 0.08 0.18 0.20 0.23
Leakage current Ileak
(20 °C, after
5 minutes)
Requirements
35
≤ ±20% of initial value
≤ 2 times initial specified value
≤ initial specified limit
After storage for 1000 h at 85 °C, the capacitors shall meet the
requirement of load life test after reforming process. After test: VR to be
applied for 30 minutes, 24 to 48 hours before measurement.
Vibration resistance test To IEC 60068-2-6, test Fc:
Frequency range 10 ... 55 Hz, displacement amplitude 0.75 mm,
acceleration max. 10 g, duration 3 × 2 h.
If can size D <16 mm, capacitor is mounted by the leads
If can size D ≥16 mm, capacitor rigidly clamped by the aluminum case
Shelf life
IEC climatic category
To IEC 60068-1:
VR ≤ 100 V DC: 40/085/56 (40 °C/+85 °C/56 days damp heat test)
VR > 100 V DC: 25/085/56 (25 °C/+85 °C/56 days damp heat test)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 39
B41827, B43827
Standard series 85 °C
Dimensional drawing
Safety vent for diameter ≥ 8 mm.
Case Dimensions
d×l
mm
5 × 11
6.3 × 11
8 × 11.5
10 × 12.5
10 × 16
10 × 20
12.5 × 20
12.5 × 25
16 × 25
16 × 31.5
16 × 35.5
18 × 35.5
18 × 40
dmax × lmax
mm
5.5 × 12.5
6.8 × 12.5
8.5 × 13.0
11.0 × 14.0
11.0 × 17.5
11.0 × 22.0
13.5 × 22.0
13.5 × 27.0
17.0 × 27.0
17.0 × 33.5
17.0 × 37.5
19.0 × 37.5
19.0 × 42.0
Please read Cautions and warnings and
Important notes at the end of this document.
a
mm
2.0 ±0.5
2.5 ±0.5
3.5 ±0.5
5.0 ±0.5
5.0 ±0.5
5.0 ±0.5
5.0 ±0.5
5.0 ±0.5
7.5 ±0.5
7.5 ±0.5
7.5 ±0.5
7.5 ±0.5
7.5 ±0.5
Page 4 of 39
b
mm
0.50 ±0.1
0.50 ±0.1
0.60 ±0.1
0.60 ±0.1
0.60 ±0.1
0.60 ±0.1
0.60 ±0.1
0.60 ±0.1
0.80 ±0.1
0.80 ±0.1
0.80 ±0.1
0.80 ±0.1
0.80 ±0.1
B41827
Standard series 85 °C
Overview of available types B41827
VR (V DC)
6.3
10
16
25
Case dimensions d × l (mm)
CR (µF)
47
5
100
5
× 11
5
× 11
× 11
6.3 × 11
220
5
× 11
6.3 × 11
6.3 × 11
8
× 11.5
330
6.3 × 11
6.3 × 11
8
× 11.5
10
× 12.5
470
6.3 × 11
8
× 11.5
8
× 11.5
10
× 12.5
× 16
10
× 20
1000
10
× 12.5
10
× 12.5
10
2200
10
× 20
10
× 20
12.5 × 20
12.5 × 25
3300
12.5 × 20
12.5 × 20
12.5 × 25
16
× 25
4700
12.5 × 25
12.5 × 25
16
× 25
16
× 31.5
6800
16
× 25
10000
16
× 25
16
× 35.5
18
× 35.5
15000
16
× 35.5
18
× 35.5
22000
18
× 40
Please read Cautions and warnings and
Important notes at the end of this document.
Page 5 of 39
B41827
Standard series 85 °C
VR (V DC)
35
50
63
100
Case dimensions d × l (mm)
CR (µF)
0.47
5
× 11
1.0
5
× 11
2.2
5
× 11
3.3
5
× 11
4.7
5
× 11
10
5
× 11
5
× 11
6.3 × 11
5
× 11
6.3 × 11
8
× 11.5
33
5
× 11
5
× 11
6.3 × 11
10
× 12.5
47
5
× 11
6.3 × 11
6.3 × 11
10
× 12.5
× 20
22
100
6.3 × 11
8
× 11.5
10
× 12.5
10
× 20
12.5 × 25
220
10
× 12.5
10
× 12.5
10
330
10
× 12.5
10
× 16
12.5 × 20
16
× 25
470
10
× 16
10
× 20
12.5 × 25
16
× 31.5
1000
12.5 × 25
16
× 20
16
18
× 40
2200
16
× 25
16
× 31.5
3300
16
× 31.5
4700
18
× 35.5
Please read Cautions and warnings and
Important notes at the end of this document.
Page 6 of 39
× 31.5
B43827
Standard series 85 °C
Overview of available types B43827
VR (V DC)
160
200
250
350
400
450
Case dimensions d × l (mm)
CR (µF)
0.47
5
× 11
5
× 11
1.0
5
× 11
5
× 11
2.2
5
× 11
3.3
6.3 × 11
6.3 × 11
4.7
6.3 × 11
8
× 11.5
8
× 11.5
10
× 12.5
× 20
6.3 × 11
6.3 × 11
8
× 11.5
6.3 × 11
8
× 11.5
6.3 × 11
8
× 11.5
8
× 11.5
10
× 12.5
6.3 × 11
10
× 12.5
10
× 12.5
10
× 16
× 11.5
10
× 12.5
10
× 16
10
× 20
10
× 12.5
10
× 20
12.5 × 20
10
× 20
12.5 × 25
12.5 × 20
10
8
22
10
× 16
10
16
× 25
16
× 25
33
10
× 20
12.5 × 20
12.5 × 25
16
× 25
16
× 25
16
× 31.5
47
12.5 × 25
12.5 × 20
12.5 × 25
16
× 35.5
16
× 35.5
18
× 40
18
× 40
100
16
× 25
16
× 25
220
16
× 35.5
18
× 35.5
330
18
× 35.5
Please read Cautions and warnings and
Important notes at the end of this document.
16
× 31.5
Page 7 of 39
B41827
Standard series 85 °C
Technical data and ordering codes B41827
CR
120 Hz, 20 °C
µF
VR = 6.3 V DC
220
330
470
1000
2200
3300
4700
6800
10000
15000
22000
VR = 10 V DC
100
220
330
470
1000
2200
3300
4700
10000
15000
VR = 16 V DC
100
220
330
470
1000
Case dimensions
d×l
mm
IAC,R
120 Hz, 85 °C
mA
Ordering code
(composition see below)
5 × 11
6.3 × 11
6.3 × 11
10 × 12.5
10 × 20
12.5 × 20
12.5 × 25
16 × 25
16 × 25
16 × 35.5
18 × 40
200
270
321
542
1005
1195
1560
1925
2360
2855
3345
B41827A2227M***
B41827A2337M***
B41827A2477M***
B41827A2108M***
B41827A2228M***
B41827A2338M***
B41827A2478M***
B41827A2688M***
B41827A2109M***
B41827A2159M***
B41827A2229M***
5 × 11
6.3 × 11
6.3 × 11
8 × 11.5
10 × 12.5
10 × 20
12.5 × 20
12.5 × 25
16 × 35.5
18 × 35.5
130
280
290
385
650
1082
1436
1783
2700
3100
B41827A3107M***
B41827A3227M***
B41827A3337M***
B41827A3477M***
B41827A3108M***
B41827A3228M***
B41827A3338M***
B41827A3478M***
B41827A3109M***
B41827A3159M***
5 × 11
6.3 × 11
8 × 11.5
8 × 11.5
10 × 16
160
261
373
446
790
B41827A4107M***
B41827A4227M***
B41827A4337M***
B41827A4477M***
B41827A4108M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk
002 = for cut leads, bulk
016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for ∅ 5 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for ∅ 5 ... 6.3 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for ∅ 5 ... 12.5 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 25 ... 16 × 31.5 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 39
B41827
Standard series 85 °C
Technical data and ordering codes B41827
CR
120 Hz, 20 °C
µF
VR = 16 V DC
2200
3300
4700
10000
VR = 25 V DC
47
100
220
330
470
1000
2200
3300
4700
VR = 35 V DC
33
47
100
220
330
470
1000
2200
3300
4700
Case dimensions
d×l
mm
IAC,R
120 Hz, 85 °C
mA
Ordering code
(composition see below)
12.5 × 20
12.5 × 25
16 × 25
18 × 35.5
1310
1695
2100
2980
B41827A4228M***
B41827A4338M***
B41827A4478M***
B41827A4109M***
5 × 11
6.3 × 11
8 × 11.5
10 × 12.5
10 × 12.5
10 × 20
12.5 × 25
16 × 25
16 × 31.5
108
192
335
446
547
962
1560
1985
2455
B41827A5476M***
B41827A5107M***
B41827A5227M***
B41827A5337M***
B41827A5477M***
B41827A5108M***
B41827A5228M***
B41827A5338M***
B41827A5478M***
5 × 11
5 × 11
6.3 × 11
10 × 12.5
10 × 12.5
10 × 16
12.5 × 25
16 × 25
16 × 31.5
18 × 35.5
102
130
212
390
495
652
1158
1810
2293
2710
B41827A7336M***
B41827A7476M***
B41827A7107M***
B41827A7227M***
B41827A7337M***
B41827A7477M***
B41827A7108M***
B41827A7228M***
B41827A7338M***
B41827A7478M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk
002 = for cut leads, bulk
016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for ∅ 5 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for ∅ 5 ... 6.3 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for ∅ 5 ... 12.5 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 25 ... 16 × 31.5 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 9 of 39
B41827
Standard series 85 °C
Technical data and ordering codes B41827
CR
120 Hz, 20 °C
µF
VR = 50 V DC
10
22
33
47
100
220
330
470
1000
2200
VR = 63 V DC
10
22
33
47
100
220
330
470
1000
VR = 100 V DC
0.47
1.0
2.2
3.3
4.7
10
22
Case dimensions
d×l
mm
IAC,R
120 Hz, 85 °C
mA
Ordering code
(composition see below)
5 × 11
5 × 11
5 × 11
6.3 × 11
8 × 11.5
10 × 12.5
10 × 16
10 × 20
16 × 20
16 × 31.5
58
85
117
155
260
430
510
700
1100
1540
B41827A6106M***
B41827A6226M***
B41827A6336M***
B41827A6476M***
B41827A6107M***
B41827A6227M***
B41827A6337M***
B41827A6477M***
B41827A6108M***
B41827A6228M***
5 × 11
6.3 × 11
6.3 × 11
6.3 × 11
10 × 12.5
10 × 20
12.5 × 20
12.5 × 25
16 × 31.5
60
100
140
170
300
475
710
900
1300
B41827A8106M***
B41827A8226M***
B41827A8336M***
B41827A8476M***
B41827A8107M***
B41827A8227M***
B41827A8337M***
B41827A8477M***
B41827A8108M***
5 × 11
5 × 11
5 × 11
5 × 11
5 × 11
6.3 × 11
8 × 11.5
13
20
29
36
43
75
130
B41827A9474M***
B41827A9105M***
B41827A9225M***
B41827A9335M***
B41827A9475M***
B41827A9106M***
B41827A9226M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk
002 = for cut leads, bulk
016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for ∅ 5 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for ∅ 5 ... 6.3 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for ∅ 5 ... 12.5 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 25 ... 16 × 31.5 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 10 of 39
B41827
Standard series 85 °C
Technical data and ordering codes B41827
CR
120 Hz, 20 °C
µF
VR = 100 V DC
33
47
100
220
330
470
1000
Case dimensions
d×l
mm
IAC,R
120 Hz, 85 °C
mA
Ordering code
(composition see below)
10 × 12.5
10 × 12.5
10 × 20
12.5 × 25
16 × 25
16 × 31.5
18 × 40
180
230
370
620
760
1000
1380
B41827A9336M***
B41827A9476M***
B41827A9107M***
B41827A9227M***
B41827A9337M***
B41827A9477M***
B41827A9108M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk
002 = for cut leads, bulk
016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for ∅ 5 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for ∅ 5 ... 6.3 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for ∅ 5 ... 12.5 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 25 ... 16 × 31.5 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 11 of 39
B43827
Standard series 85 °C
Technical data and ordering codes B43827
CR
120 Hz, 20 °C
µF
VR = 160 V DC
0.47
1.0
2.2
3.3
4.7
10
22
33
47
100
220
330
VR = 200 V DC
3.3
4.7
10
22
33
47
100
220
VR = 250 V DC
0.47
1.0
2.2
3.3
4.7
10
Case dimensions
d×l
mm
IAC,R
120 Hz, 85 °C
mA
Ordering code
(composition see below)
5 × 11
5 × 11
5 × 11
6.3 × 11
6.3 × 11
8 × 11.5
10 × 16
10 × 20
12.5 × 25
16 × 25
16 × 35.5
18 × 35.5
15
22
33
40
49
80
152
203
268
423
786
945
B43827A1474M***
B43827A1105M***
B43827A1225M***
B43827A1335M***
B43827A1475M***
B43827A1106M***
B43827A1226M***
B43827A1336M***
B43827A1476M***
B43827A1107M***
B43827A1227M***
B43827A1337M***
6.3 × 11
8 × 11.5
10 × 12.5
10 × 20
12.5 × 20
12.5 × 20
16 × 25
18 × 35.5
40
56
95
170
225
267
490
815
B43827A2335M***
B43827A2475M***
B43827A2106M***
B43827A2226M***
B43827A2336M***
B43827A2476M***
B43827A2107M***
B43827A2227M***
5 × 11
5 × 11
6.3 × 11
6.3 × 11
8 × 11.5
10 × 12.5
15
22
33
47
56
103
B43827F2474M***
B43827F2105M***
B43827F2225M***
B43827F2335M***
B43827F2475M***
B43827F2106M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk
002 = for cut leads, bulk
016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for ∅ 5 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for ∅ 5 ... 6.3 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for ∅ 5 ... 12.5 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 25 ... 16 × 31.5 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 12 of 39
B43827
Standard series 85 °C
Technical data and ordering codes B43827
CR
120 Hz, 20 °C
µF
VR = 250 V DC
22
33
47
100
VR = 350 V DC
1.0
2.2
3.3
4.7
10
22
33
47
100
VR = 400 V DC
0.47
1.0
2.2
3.3
4.7
10
22
33
47
Case dimensions
d×l
mm
IAC,R
120 Hz, 85 °C
mA
Ordering code
(composition see below)
10 × 20
12.5 × 25
12.5 × 25
16 × 31.5
185
225
268
525
B43827F2226M***
B43827F2336M***
B43827F2476M***
B43827F2107M***
6.3 × 11
8 × 11.5
10 × 12.5
10 × 12.5
10 × 20
12.5 × 25
16 × 25
16 × 35.5
18 × 40
22
38
54
65
115
185
276
334
510
B43827A4105M***
B43827A4225M***
B43827A4335M***
B43827A4475M***
B43827A4106M***
B43827A4226M***
B43827A4336M***
B43827A4476M***
B43827A4107M***
6.3 × 11
6.3 × 11
8 × 11.5
10 × 12.5
10 × 16
12.5 × 20
16 × 25
16 × 25
16 × 35.5
15
23
40
55
67
118
200
280
362
B43827A9474M***
B43827A9105M***
B43827A9225M***
B43827A9335M***
B43827A9475M***
B43827A9106M***
B43827A9226M***
B43827A9336M***
B43827A9476M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk
002 = for cut leads, bulk
016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for ∅ 5 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for ∅ 5 ... 6.3 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for ∅ 5 ... 12.5 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 25 ... 16 × 31.5 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 13 of 39
B43827
Standard series 85 °C
Technical data and ordering codes B43827
CR
120 Hz, 20 °C
µF
VR = 450 V DC
0.47
1.0
2.2
3.3
4.7
10
22
33
47
Case dimensions
d×l
mm
IAC,R
120 Hz, 85 °C
mA
Ordering code
(composition see below)
8 × 11.5
8 × 11.5
10 × 12.5
10 × 16
10 × 20
12.5 × 20
16 × 25
16 × 31.5
18 × 40
18
24
36
44
56
95
170
235
302
B43827A5474M***
B43827A5105M***
B43827A5225M***
B43827A5335M***
B43827A5475M***
B43827A5106M***
B43827A5226M***
B43827A5336M***
B43827A5476M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk
002 = for cut leads, bulk
016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for ∅ 5 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for ∅ 5 ... 6.3 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for ∅ 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for ∅ 5 ... 12.5 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d × l = 16 × 25 ... 16 × 31.5 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 14 of 39
B41827, B43827
Standard series 85 °C
Useful life
depending on ambient temperature TA under ripple current operating conditions1)
B41827
Useful life
depending on ambient temperature TA under ripple current operating conditions1)
B43827
1) Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life
graphs.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 15 of 39
B41827, B43827
Standard series 85 °C
Frequency factor of permissible ripple current IAC versus frequency f
Please read Cautions and warnings and
Important notes at the end of this document.
Page 16 of 39
B41827, B43827
Standard series 85 °C
Taping, packing and lead configurations
Taping
Single-ended capacitors are available taped in Ammo pack from diameter 4 to 18 mm as follows:
Lead spacing F = 2.0 mm (∅ d = 4 … 5 mm)
Lead spacing F = 2.5 mm (∅ d = 4 … 6.3 mm)
Lead spacing F = 3.5 mm (∅ d = 8 mm)
Lead spacing F = 5.0 mm (∅ d = 4 … 12.5 mm)
Lead spacing F = 7.5 mm (∅ d = 16 ... 18 mm).
Lead spacing 2.0 mm (∅ d = 4 ... 5 mm)
Last 3 digits of ordering code: 016
Dimensions in mm
∅d
F
4 ... 5 2.0
H
W
W0
W1
W2
P
P0
P1
I1
t
∆h
18.5
18.0
7.0
9.0
3.0
12.7
12.7
5.10
1.0
0.7
1
D0
4.0
min.
±0.5
max. ±1.0
±0.3
±0.7
max. ±0.2
±1.0
±0.2
+0.8
±0.75 ±0.5
0.2
Please read Cautions and warnings and
Important notes at the end of this document.
Page 17 of 39
B41827, B43827
Standard series 85 °C
Lead spacing 2.5 mm (∅ d = 4 ... 6.3 mm)
Last 3 digits of ordering code: 007
Dimensions in mm
∅d
4 ... 6.3
Tolerrance
F
H
W0
W1
W2
2.5
18.5 18.0 5.5
W
9.0
1.5
H0
P
P0
P1
16.0 12.7 12.7 5.1
I1
t
∆h
1.0
0.7
1.0
D0
4.0
+0.8
±0.75 ±0.5 min. ±0.5 max. ±0.5 ±1.0 ±0.2 ±0.5 max. ±0.2 max. ±0.2
0.2
Lead spacing 3.5 mm (∅ d = 8 mm)
Last 3 digits of ordering code: 006
Dimensions in mm
∅d
8
F
3.5
H
18.5
W
18.0
W0
10
W1
9.0
W2
3.0
P
12.7
P0
12.7
P1
4.6
I1
1.0
t
0.7
Toler- +0.8
±1.0
ance 0.2
±0.5
min.
±0.5
max. ±1.0
±0.3
±0.6
max. ±0.2
∆h
1.0
max. ±0.2
Leads can also run straight through the taping area. Taping is available up to dimensions
d × l = 8 × 15 mm.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 18 of 39
D0
4.0
B41827, B43827
Standard series 85 °C
Lead spacing 5.0 mm (∅ d = 4 ... 8 mm)
Last 3 digits of ordering code: 008
Lead spacing 5.0 mm (∅ d = 10 ... 12.5 mm)
Last 3 digits of ordering code: 008
Dimensions in mm
∅d
4 ...
6.3
F
H
W
W0
W1
W2
H0
P
P0
P1
I1
t
∆h
D0
5.0
18.5
18.0 5.5
9.0
1.5
16.0
12.7
12.7
3.85
1.0
0.6
1.0
4.0
20.0
10.0
16.0
12.7
12.7
3.85
19.0
18.0 12.5 9.0
1.5
12.7
12.7
3.85
1.0
0.6
1.0
4.0
15.0
15.0
5.0
±1.0
±0.2
±0.5
max.
+0.3
max. ±0.2
0.2
8
10
5.0
12.5
12.5
19.0
Toler- +0.8
±0.75 ±0.5 min. ±0.5 max. ±0.5
ance 0.2
Taping is available up to dimensions d × l = 10 × 31.5 mm and 12.5 × 25 mm.
Taping is not available for d × l = 8 × 20 mm.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 19 of 39
B41827, B43827
Standard series 85 °C
Lead spacing 7.5 mm (∅ d = 16 ...18 mm)
Last 3 digits of ordering code: 009
Dimensions in mm
∅d
16
F
H
W
7.5 18.5 18.0
18
Toler0.5
±0.8
±0.5
ance
+0.75
W0
W1
W2
P
P0
P1
I1
t
∆P
∆h
D0
12.5
9.0
1.5
30.0
15.0
3.75
1.0
0.7
0
0
4.0
min.
±0.5
max. ±1.0
±0.2
±0.5
max. ±0.2 ±1.0 ±1.0 ±0.2
Taping is available up to dimensions d × l = 16 × 31.5 mm and 18 × 31.5 mm.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 20 of 39
B41827, B43827
Standard series 85 °C
Cut or kinked leads
Single-ended capacitors are available with cut or kinked leads. Other lead configurations also
available upon request.
Cut leads (Chapter A)
Available for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086,
B43088, B43827, B43828.
Last 3 digits of ordering code: 002
Case size d x l (mm)
4
x7
Dimensions
(mm)
a ±0.5
1.5
12.5 x 16
Dimensions
(mm)
a ±0.5
5.0
5
x7
2.0
12.5 x 20
5.0
5
x 11
2.0
12.5 x 25
5.0
6.3 x 7
2.5
12.5 x 31.5
5.0
6.3 x 11
2.5
12.5 x 35.5
5.0
8
x7
3.5
12.5 x 40
5.0
8
x 11.5
3.5
16
x 20
7.5
8
x 15
3.5
16
x 25
7.5
8
x 20
3.5
16
x 31.5
7.5
10
x 12.5
5.0
16
x 35.5
7.5
10
x 16
5.0
16
x 40
7.5
10
x 20
5.0
18
x 20
7.5
10
x 25
5.0
18
x 25
7.5
10
x 31.5
5.0
18
x 31.5
7.5
18
x 35.5
7.5
18
x 40
7.5
Please read Cautions and warnings and
Important notes at the end of this document.
Case size d x l (mm)
Page 21 of 39
B41827, B43827
Standard series 85 °C
Cut leads (Chapter B)
Available for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896,
B42824, B42851, B43866, B43867, B43890, B43896.
Last 3 digits of ordering code: 002
With stand-off rubber seal
Case size
d × l (mm)
With flat rubber seal
Please read Cautions and warnings and
Important notes at the end of this document.
Page 22 of 39
Dimensions (mm)
a ±0.5
10 × 12.5
5.0
10 × 16
5.0
10 × 20
5.0
12.5 × 20
5.0
12.5 × 25
5.0
16 × 20
7.5
16 × 25
7.5
16 × 31.5
7.5
16 × 35.5
7.5
18 × 20
7.5
18 × 25
7.5
18 × 31.5
7.5
18 × 35
7.5
18 × 40
7.5
B41827, B43827
Standard series 85 °C
Kinked leads (Chapter A)
Available for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086,
B43088, B43827, B43828.
Last 3 digits of ordering code: 001
Case size d x l (mm)
4
x7
Dimensions
(mm)
a ±0.5
1.5
12.5 x 16
Dimensions
(mm)
a ±0.5
5.0
5
x7
2.0
12.5 x 20
5.0
5
x 11
2.0
12.5 x 25
5.0
6.3 x 7
2.5
12.5 x 31.5
5.0
6.3 x 11
2.5
12.5 x 35.5
5.0
8
x7
3.5
12.5 x 40
5.0
8
x 11.5
3.5
16
x 20
7.5
8
x 15
3.5
16
x 25
7.5
8
x 20
3.5
16
x 31.5
7.5
10
x 12.5
5.0
16
x 35.5
7.5
10
x 16
5.0
16
x 40
7.5
10
x 20
5.0
18
x 20
7.5
10
x 25
5.0
18
x 25
7.5
10
x 31.5
5.0
18
x 31.5
7.5
18
x 35.5
7.5
18
x 40
7.5
Please read Cautions and warnings and
Important notes at the end of this document.
Case size d x l (mm)
Page 23 of 39
B41827, B43827
Standard series 85 °C
Kinked leads (Chapter B)
Available for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896,
B42824, B42851, B43866, B43867, B43890, B43896.
Last 3 digits of ordering code: 001
With stand-off rubber seal
Case size
d × l (mm)
With flat rubber seal
Please read Cautions and warnings and
Important notes at the end of this document.
Page 24 of 39
Dimensions (mm)
a ±0.5
10 × 20
5.0
12.5 × 20
5.0
12.5 × 25
5.0
16 × 20
7.5
16 × 25
7.5
16 × 31.5
7.5
16 × 35.5
7.5
18 × 20
7.5
18 × 25
7.5
18 × 31.5
7.5
18 × 35
7.5
18 × 40
7.5
B41827, B43827
Standard series 85 °C
PAPR leads (Protection Against Polarity Reversal)
These lead configurations ensure correct placement of the capacitor on the PCB with regard to
polarity. PAPR leads are available for diameters from 10 mm up to 18 mm.
There are three configurations available: Crimped leads, J leads, bent 90° leads
Available for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896,
B42824, B42851, B43866, B43867, B43890, B43896.
Crimped leads
Last 3 digits of ordering code: 003
With stand-off rubber seal
With flat rubber seal
Suggestion for PCB hole diameter
Case size
d × l (mm)
Dimensions (mm)
B ±0.2
C ±0.5
D ±0.1
E ±0.1
16 × 20
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
16 × 25
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
16 × 31.5
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
16 × 35.5
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
18 × 20
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 25
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 31.5
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 35
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 40
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
Please read Cautions and warnings and
Important notes at the end of this document.
Page 25 of 39
a ±0.5
∅b
B41827, B43827
Standard series 85 °C
J leads
Last 3 digits of ordering code: 004
Suggestion for PCB hole diameter
Case size
d × l (mm)
Dimensions (mm)
C ±0.5
E ±0.5
J ±0.2
10 × 12.5
3.2
0.7
1.2
5.0
0.6 ±0.05
10 × 16
3.2
0.7
1.2
5.0
0.6 ±0.05
10 × 20
3.2
0.7
1.2
5.0
0.6 ±0.05
12.5 × 20
3.2
0.7
1.2
5.0
0.6 ±0.05
12.5 × 25
3.2
0.7
1.2
5.0
0.6 ±0.05
16 × 20
3.5
0.7
1.6
7.5
0.8 ±0.05
16 × 25
3.5
0.7
1.6
7.5
0.8 ±0.05
16 × 31.5
3.5
0.7
1.6
7.5
0.8 ±0.05
16 × 35.5
3.5
0.7
1.6
7.5
0.8 ±0.05
18 × 20
3.5
0.7
1.6
7.5
0.8 ±0.1
18 × 25
3.5
0.7
1.6
7.5
0.8 ±0.1
18 × 31.5
3.5
0.7
1.6
7.5
0.8 ±0.1
18 × 35
3.5
0.7
1.6
7.5
0.8 ±0.1
Please read Cautions and warnings and
Important notes at the end of this document.
Page 26 of 39
a ±0.5
∅b
B41827, B43827
Standard series 85 °C
Bent 90° leads for horizontal mounting pinning
Last 3 digits of ordering code: 012
Case size
d × l (mm)
Dimensions (mm)
C ±0.5
E ±0.5
F ±0.5
a ±0.5
∅b
16 × 20
4.0
4.0
12.0
7.5
0.8 ±0.05
16 × 25
4.0
4.0
12.0
7.5
0.8 ±0.05
16 × 31.5
4.0
4.0
12.0
7.5
0.8 ±0.05
16 × 35.5
4.0
4.0
12.0
7.5
0.8 ±0.05
18 × 20
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 25
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 31.5
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 35
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 40
4.0
4.0
13.0
7.5
0.8 ±0.1
Bent leads for diameter 12.5 mm available upon request.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 27 of 39
B41827, B43827
Standard series 85 °C
Packing units and box dimensions
Ammo pack
Valid for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088,
B43827, B43828.
Please read Cautions and warnings and
Important notes at the end of this document.
Case size
d×l
mm
Dimensions (mm)
Amax
Bmax
Cmax
Packing
units
pcs.
4×7
330
50
196
2000
5×7
330
50
226
2000
5 × 11
330
50
226
2000
6.3 × 7
330
50
286
2000
6.3 × 11
330
50
286
2000
8×7
330
50
246
1000
8 × 11.5
330
50
246
1000
8 × 15
330
50
246
500
10 × 12.5
330
50
196
500
10 × 16
330
54
196
500
10 × 20
330
58
196
500
12.5 × 20
341
60
272
500
12.5 × 25
341
65
272
500
16 × 25
320
65
270
300
16 × 31.5
315
65
275
300
18 × 20
315
65
275
250
18 × 25
315
65
275
250
18 × 31.5
315
65
275
250
Page 28 of 39
B41827, B43827
Standard series 85 °C
Ammo pack
Valid for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824,
B42851, B43866, B43867, B43890, B43896.
Please read Cautions and warnings and
Important notes at the end of this document.
Case size
d×l
mm
Dimensions (mm)
Amax
Bmax
Cmax
Packing
units
pcs.
8 × 11.5
345
55
240
1000
10 × 12.5
345
55
280
750
10 × 16
345
60
200
500
10 × 20
345
60
200
500
12.5 × 20
345
65
280
500
12.5 × 25
345
65
280
500
16 × 20
315
65
275
300
16 × 25
315
65
275
300
16 × 31.5
315
65
275
300
18 × 20
315
65
275
250
18 × 25
315
65
275
250
18 × 31.5
315
65
275
250
Page 29 of 39
B41827, B43827
Standard series 85 °C
Overview of packing units and code numbers for case sizes 4 x 7 ... 16 x 40
Valid for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088,
B43827, B43828.
Case size
dxl
mm
Standard,
bulk
pcs.
Taped,
Ammo pack
pcs.
Kinked leads,
bulk
pcs.
Cut leads,
bulk
pcs.
4
x7
10000
2000
15000
15000
5
x7
7500
2000
10000
10000
5
x 11
5000
2000
10000
10000
6.3 x 7
5000
2000
10000
10000
6.3 x 11
5000
2000
5000
5000
8
x7
5000
1000
5000
5000
8
x 11.5
2500
1000
4000
4000
8
x 15
2000
1000
2500
2500
8
x 20
1500
2000
2000
10
x 12.5
2000
500
2500
2500
10
x 16
1500
500
2000
2000
10
x 20
1000
500
1500
1500
10
x 25
1000
500
1250
1250
12.5 x 16
750
500
1000
1000
12.5 x 20
750
500
500
500
12.5 x 25
750
500
500
500
12.5 x 31.5
500
750
750
12.5 x 35.5
500
750
750
12.5 x 40
500
750
750
16
x 20
375
300
500
500
16
x 25
375
300
500
500
16
x 31.5
250
300
375
375
16
x 35.5
250
375
375
16
x 40
250
The last three
digits of the
complete
ordering code
state the lead
configuration
000
Please read Cautions and warnings and
Important notes at the end of this document.
375
Code
F (mm) d (mm)
006
007
008
009
016
3.5
2.5
5.0
7.5
2.0
8
4 ... 6.3
4 ... 12.5
16 ... 18
4 ... 5
Page 30 of 39
001
375
002
B41827, B43827
Standard series 85 °C
Overview of packing units and code numbers for case sizes 18 x 20 ... 18 x 40
Valid for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088,
B43827, B43828.
Case size
dxl
mm
Standard,
bulk
pcs.
Taped,
Ammo pack
pcs.
Kinked leads,
bulk
pcs.
Cut leads,
bulk
pcs.
18
x 20
250
250
100
100
18
x 25
250
250
100
100
18
x 31.5
250
250
100
100
18
x 35.5
250
100
100
18
x 40
250
The last three
digits of the
complete
ordering code
state the lead
configuration
000
Please read Cautions and warnings and
Important notes at the end of this document.
100
Code
F (mm) d (mm)
009
7.5
16 ... 18
Page 31 of 39
001
100
002
B41827, B43827
Standard series 85 °C
Overview of packing units and code numbers for case sizes 8 × 11.5 ... 16 × 35.5
Valid for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824,
B42851, B43866, B43867, B43890, B43896.
PAPR
Case size
d×l
Taped,
Ammo pack
mm
Standard,
bulk
pcs.
pcs.
Kinked
leads,
bulk
pcs.
Cut
leads,
bulk
pcs.
Crimped J leads,
leads,
blister
blister
pcs.
pcs.
1000
8 × 11.5
1000
10 × 12.5
1000
750
10 × 16
1000
500
1000
10 × 20
500
500
500
500
12.5 × 20
350
500
350
350
12.5 × 25
250
500
500
500
12.5 × 30
200
12.5 × 35
175
12.5 × 40
175
16 × 20
250
300
200
200
200
200
120
16 × 25
250
300
200
200
200
200
120
16 × 31.5
200
300
250
250
344
344
120
16 × 35.5
100
100
100
150
150
150
The last three
digits of the
complete
ordering code
state the lead
configuration
000
Code F (mm) d (mm)
001
002
003
004
012
006
008
009
3.5
5
7.5
8
5...12.5
16...18
1) Available upon request
Please read Cautions and warnings and
Important notes at the end of this document.
Page 32 of 39
1000
Bent 90°
leads,
blister
pcs.
675
675
500
300
1)
225
1)
B41827, B43827
Standard series 85 °C
Overview of packing units and code numbers for case sizes 18 × 20 ... 18 × 40
Valid for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824,
B42851, B43866, B43867, B43890, B43896.
PAPR
Case size
d×l
Taped,
Ammo pack
mm
Standard,
bulk
pcs.
pcs.
Kinked
leads,
bulk
pcs.
Cut
leads,
bulk
pcs.
Crimped J leads,
leads,
blister
blister
pcs.
pcs.
Bent 90°
leads,
blister
pcs.
18 × 20
175
18 × 25
150
250
175
175
200
200
120
250
150
150
200
200
18 × 31.5
120
100
250
100
100
150
150
120
18 × 35
100
100
100
150
150
150
18 × 40
125
100
100
120
72
The last three
digits of the
complete
ordering code
state the lead
configuration
000
Code F (mm) d (mm)
001
002
003
004
012
009
Please read Cautions and warnings and
Important notes at the end of this document.
7.5
16...18
Page 33 of 39
B41827, B43827
Standard series 85 °C
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have not only been optimized with a view to the intended
application, but also with regard to health and environmental compatibility. They do not contain
any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They
contain flame-retarding substances which will quickly extinguish any flame that may have been
ignited.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no safe substitute materials are
currently known. However, the amount of dangerous materials used in our products has been
limited to an absolute minimum. Nevertheless, the following rules should be observed when
handling aluminum electrolytic capacitors:
Any escaping electrolyte should not come into contact with eyes or skin.
If electrolyte does come into contact with the skin, wash the affected parts immediately with
running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If
symptoms persist, seek medical treatment.
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be
well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 34 of 39
B41827, B43827
Standard series 85 °C
Product safety
The table below summarizes the safety instructions that must be observed without fail. A detailed
description can be found in the relevant sections of chapter "General technical information".
Topic
Safety information
Polarity
Make sure that polar capacitors are connected
with the right polarity.
Reverse voltage
Voltages polarity classes should be prevented by
connecting a diode.
Do not exceed the upper category temperature.
Upper category
temperature
Maintenance
Mounting
position of screwterminal capacitors
Mounting of
single-ended
capacitors
Robustness of
terminals
Soldering
Make periodic inspections of the capacitors.
Before the inspection, make sure that the power
supply is turned off and carefully discharge the
electricity of the capacitors.
Do not apply any mechanical stress to the
capacitor terminals.
Do not mount the capacitor with the terminals
(safety vent) upside down.
Reference
chapter "General
technical information"
1
"Basic construction of
aluminum electrolytic
capacitors"
3.1.6
"Reverse voltage"
7.2
"Maximum permissible
operating temperature"
10
"Maintenance"
11.1.
"Mounting positions of
capacitors with screw
terminals"
The internal structure of single-ended capacitors 11.4
might be damaged if excessive force is applied to "Mounting
the lead wires.
considerations for
Avoid any compressive, tensile or flexural stress. single-ended capacitors"
Do not move the capacitor after soldering to PC
board.
Do not pick up the PC board by the soldered
capacitor.
Do not insert the capacitor on the PC board with a
hole space different to the lead space specified.
The following maximum tightening torques must
11.3
not be exceeded when connecting screw
"Mounting torques"
terminals:
M5: 2 Nm
M6: 2.5 Nm
Do not exceed the specified time or temperature 11.5
limits during soldering.
"Soldering"
Please read Cautions and warnings and
Important notes at the end of this document.
Page 35 of 39
B41827, B43827
Standard series 85 °C
Topic
Soldering,
cleaning agents
Passive
flammability
Active
flammability
Safety information
Reference
chapter "General
technical information"
Do not allow halogenated hydrocarbons to come 11.6
into contact with aluminum electrolytic capacitors. "Cleaning agents"
Avoid external energy, such as fire or electricity.
8.1
"Passive flammability"
Avoid overload of the capacitors.
8.2
"Active flammability"
Breakdown strength Do not damage the insulating sleeve, especially
of insulating
when ring clips are used for mounting.
sleeves
Please read Cautions and warnings and
Important notes at the end of this document.
Page 36 of 39
Reference
chapter "Capacitors with
screw terminals"
"Screw terminals accessories"
B41827, B43827
Standard series 85 °C
Symbols and terms
Symbol
English
German
C
CR
CS
CS,T
Cf
d
dmax
ESL
ESR
ESRf
Capacitance
Rated capacitance
Series capacitance
Series capacitance at temperature T
Capacitance at frequency f
Case diameter, nominal dimension
Maximum case diameter
Self-inductance
Equivalent series resistance
Equivalent series resistance at
frequency f
Equivalent series resistance at
temperature T
Frequency
Current
Alternating current (ripple current)
Root-mean-square value of alternating
current
Ripple current at frequency f
Maximum permissible ripple current
Rated ripple current
Rated ripple current for base cooling
Leakage current
Operating leakage current
Case length, nominal dimension
Maximum case length (without
terminals and mounting stud)
Resistance
Insulation resistance
Balancing resistance
Temperature
Temperature difference
Ambient temperature
Case temperature
Capacitor base temperature
Time
Period
Service life (operating hours)
Kapazität
Nennkapazität
Serienkapazität
Serienkapazität bei Temperatur T
Kapazität bei Frequenz f
Gehäusedurchmesser, Nennmaß
Maximaler Gehäusedurchmesser
Eigeninduktivität
Ersatzserienwiderstand
Ersatzserienwiderstand bei Frequenz f
ESRT
f
I
IAC
IAC,rms
IAC,f
IAC,max
IAC,R
IAC,R (B)
Ileak
Ileak,op
l
lmax
R
Rins
Rsymm
T
∆T
TA
TC
TB
t
∆t
tb
Please read Cautions and warnings and
Important notes at the end of this document.
Ersatzserienwiderstand bei Temperatur T
Frequenz
Strom
Wechselstrom
Wechselstrom, Effektivwert
Wechselstrom bei Frequenz f
Maximal zulässiger Wechselstrom
Nennwechselstrom
Nennwechselstromstrom für Bodenkühlung
Reststrom
Betriebsreststrom
Gehäuselänge, Nennmaß
Maximale Gehäuselänge (ohne Anschlüsse
und Gewindebolzen)
Widerstand
Isolationswiderstand
Symmetrierwiderstand
Temperatur
Temperaturdifferenz
Umgebungstemperatur
Gehäusetemperatur
Temperatur des Becherbodens
Zeit
Zeitraum
Brauchbarkeitsdauer (Betriebszeit)
Page 37 of 39
B41827, B43827
Standard series 85 °C
Symbol
V
VF
Vop
VR
VS
XC
XL
Z
ZT
tan δ
λ
ε0
εr
ω
English
Voltage
Forming voltage
Operating voltage
Rated voltage, DC voltage
Surge voltage
Capacitive reactance
Inductive reactance
Impedance
Impedance at temperature T
Dissipation factor
Failure rate
Absolute permittivity
Relative permittivity
Angular velocity; 2 π f
German
Spannung
Formierspannung
Betriebsspannung
Nennspannung, Gleichspannung
Spitzenspannung
Kapazitiver Blindwiderstand
Induktiver Blindwiderstand
Scheinwiderstand
Scheinwiderstand bei Temperatur T
Verlustfaktor
Ausfallrate
Elektrische Feldkonstante
Dielektrizitätszahl
Kreisfrequenz; 2 π f
Note
All dimensions are given in mm.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 38 of 39
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap,
DigiSiMic, DSSP, FormFit, MiniBlue, MiniCell, MKK, MKD, MLSC, MotorCap, PCC,
PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap,
SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be
found on the Internet at www.epcos.com/trademarks.
Page 39 of 39
Similar pages