Delta DCL12S0A0S06PFA Non-isolated point of load dc/dc power modules: 2.4-5.5vin 0.6-3.3v/3aout Datasheet

DCT04S0A0S03NFA
FEATURES

High efficiency: 96.5% @ 5.0Vin, 3.3V3A out

Small size and low profile:
12.2x 12.2x 7.25mm (0.48”x 0.48”x 0.29”)

Surface mount packaging

Standard footprint

Voltage and resistor-based trim

Pre-bias startup

Output voltage tracking

No minimum load required

Output voltage programmable from
0.6Vdc to 3.3Vdc via external resistor

Fixed frequency operation

Input UVLO, output OCP

Remote on/off

ISO 9001, TL 9000, ISO 14001, QS9000,
OHSAS18001 certified manufacturing facility

UL/cUL 60950-1 (US & Canada)
Delphi DCT, Non-Isolated Point of Load
DC/DC Power Modules: 2.4-5.5Vin,
0.6-3.3V/3Aout
OPTIONS
The Delphi Series DCT, 2.4-5.5V input, single output,
non-isolated Point of Load DC/DC converters are the latest

Positive on/off logic

Tracking feature
offering from a world leader in power systems technology
and manufacturing -- Delta Electronics, Inc. The DCT series
provides a programmable output voltage from 0.6V to 3.3V
using
an
external
resistor
and
has
flexible
and
programmable tracking features to enable a variety of startup
voltages as well as tracking between power modules. This
product family is available in surface mount and provides up
to 3A of output current in an industry standard footprint. With
APPLICATIONS

Telecom / DataCom
creative design technology and optimization of component

Distributed power architectures
placement, these converters possess outstanding electrical

Servers and workstations
and thermal performance, as well as extremely high

LAN / WAN applications

Data processing applications
reliability under highly stressful operating conditions.
DATASHEET
DS_ DCT04S0A0S03NFA _05292012

E-mail: [email protected]
http://www.deltaww.com/dcdc
P1
TECHNICAL SPECIFICATIONS
PARAMETER
NOTES and CONDITIONS
DCT04S0A0S03NFA
Min.
ABSOLUTE MAXIMUM RATINGS
Input Voltage (Continuous)
Tracking Voltage
Operating Ambient Temperature
Storage Temperature
INPUT CHARACTERISTICS
Operating Input Voltage
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Maximum Input Current
No-Load Input Current
Off Converter Input Current
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
Vo ≦ Vin –0.6
Max.
Units
-0.3
-0.3
-40
-55
6
Vin,max
85
125
Vdc
Vdc
°C
°C
2.4
5.5
V
2.2
2.0
15
5
(5Hz to 20MHz, 1μH source impedance; VIN =0 to 5.5V, Io= Iomax ;
25
3.25
mAp-p
40
dB
1
with 0.5% tolerance for
external resistor used to set output voltage)
Output Voltage Adjustable Range
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
RMS
Output Current Range
Output Voltage Over-shoot at Start-up
Output DC Current-Limit Inception
Output Short-Circuit Current (Hiccup Mode)
DYNAMIC CHARACTERISTICS
Dynamic Load Response
Positive Step Change in Output Current
Negative Step Change in Output Current
Settling Time to 10% of Peak Deviation
Turn-On Transient
Start-Up Time, From On/Off Control
Start-Up Time, From Input
Output Voltage Rise Time
Output Capacitive Load
EFFICIENCY
Vo=3.3V
Vo=2.5V
Vo=1.8V
Vo=1.5V
Vo=1.2V
Vo=0.6V
FEATURE CHARACTERISTICS
Switching Frequency
ON/OFF Control, (Negative logic)
Logic Low Voltage
Logic High Voltage
Logic Low Current
Logic High Current
ON/OFF Control, (Positive Logic)
Logic High Voltage
Logic Low Voltage
Logic Low Current
Logic High Current
0Tracking Slew Rate Capability
Tracking Delay Time
Tracking Accuracy
GENERAL SPECIFICATIONS
MTBF
Weight
V
V
A
mA
mA
A2S
Vin=2.4V to 5.5V, Vo=1.8V, Io=Io,max,
Vin=5V
Vin=5V
Input Ripple Rejection (120Hz)
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Typ.
For Vo>=2.5V
For Vo<2.5V
For Vo>=2.5V
For Vo<2.5V
Ta=-40℃ to 85℃
Over sample load, line and temperature
5Hz to 20MHz bandwidth
Full Load, 1µF ceramic, 10µF tantalum
Full Load, 1µF ceramic, 10µF tantalum
-1.5
+1.5
% Vo,set
0.6
Vo,set
3.3
V
-3.0
0.4
10
10
5
0.4
+3.0
% Vo,set
mV
mV
mV
% Vo,set
% Vo,set
35
15
3
1
250
1
mV
mV
A
% Vo,set
% Io
Adc
180
180
500
mV
mV
µs
2
2
2
ms
ms
ms
µF
µF
25
10
0
Vout=3.3V
Hiccup mode,
Io,s/c
10µF Tan & 1µF Ceramic load cap,
2.5A/µs,Co=47u,Vin=5V,Vo=1.8V
0-50% Iomax
50% Iomax-0
Io=Io.max
Von/off, Vo=10% of Vo,set
Vin=Vin,min, Vo=10% of Vo,set
Time for Vo to rise from 10% to 90% of Vo,set
Full load; ESR ≧0.15mΩ
Full load; ESR ≧10mΩ
47
47
Vin=5V, 100% Load
Vin=5V, 100% Load
Vin=5V, 100% Load
Vin=5V, 100% Load
Vin=5V, 100% Load
Vin=5V, 100% Load
Module On, Von/off
Module Off, Von/off
Module On, Ion/off
Module Off, Ion/off
-0.2
Vin-0.8
Module On, Von/off
Module Off, Von/off
Module On, Ion/off
Module Off, Ion/off
1.6
-0.3
Delay from Vin.min to application of tracking voltage
Power-up
2V/mS
Power-down 1V/mS
Io=80% of Io, max; Ta=25°C
5
1000
3000
96.5
95.5
93.5
92.0
90.0
83.0
%
%
%
%
%
%
600
kHz
0.2
0.2
0.1
10
Vin-1.6
Vin,max
200
1
V
V
µA
mA
Vin,max
0.3
1
10
2
V
V
mA
µA
V/msec
ms
mV
mV
100
100
1
2.0
M hours
grams
(TA = 25°C, airflow rate = 300 LFM, Vin =2.4Vdc to 5.5Vdc, nominal Vout unless otherwise noted.)
DS_DCT04S0A0S03NFA_05292012
E-mail: [email protected]
http://www.deltaww.com/dcdc
P2
ELECTRICAL CHARACTERISTICS CURVES
Figure 1: Converter efficiency vs. output current (0.6V out)
Figure 2: Converter efficiency vs. output current (1.2V out)
Figure 3: Converter efficiency vs. output current (1.5V out)
Figure 4: Converter efficiency vs. output current (1.8V out)
Figure 5: Converter efficiency vs. output current (2.5V out)
DS_DCT04S0A0S03NFA_05292012
Figure 6: Converter efficiency vs. output current (3.3V out)
E-mail: [email protected]
http://www.deltaww.com/dcdc
P3
ELECTRICAL CHARACTERISTICS CURVES (CON.)
Figure 7: Output ripple & noise at 5Vin, 0.6V/3A out. (2us/div and
Figure 8: Output ripple & noise at 5Vin, 1.2V/3A out. (2us/div and
5mV/div)
5mV/div)
Figure 9: Output ripple & noise at 5Vin, 1.8V/3A out. (2us/div and
Figure 10: Output ripple & noise at 5Vin, 3.3V/3A out. (2us/div and
5mV/div)
5mV/div)
DS_DCT04S0A0S03NFA_05292012
E-mail: [email protected]
http://www.deltaww.com/dcdc
P4
Figure 11: Turn on delay time at 5Vin, 0.6V/3A out(2mS/div),Top
Figure 12: Turn on delay time at 5Vin, 1.2V/3A out(2mS/div),Top
trace:Vout 0.2V/div; bottom trace:Vin,5V/div
trace:Vout 0.5V/div; bottom trace:Vin,5V/div
DS_DCT04S0A0S03NFA_05292012
E-mail: [email protected]
http://www.deltaww.com/dcdc
P5
Electrical Characteristics Curves (con.)
Figure 13: Turn on delay time at 5Vin, 1.8V/3A out(2mS/div),Top
Figure 14: Turn on delay time at 5Vin, 3.3V/3A out(2mS/div),Top
trace:Vout 1V/div; bottom trace:Vin,5V/div
trace:Vout 2V/div; bottom trace:Vin,5V/div
Figure 15: Turn on delay time at remote on/off, 0.6V/3A
Figure 16: Turn on delay time at remote on/off, 3.3V/3A
out(2mS/div),Top trace:Vout 2V/div; bottom trace: on/off,2V/div
out(2mS/div),Top trace:Vout 0.2V/div; bottom trace: on/off,2V/div
Figure 17: Turn on delay time at remote turn on with external
capacitors (Co= 3000 µF) 5Vin, 3.3V/3A out
DS_DCT04S0A0S03NFA_05292012
Figure 18: Turn on delay time at remote turn on with external
capacitors (Co= 3000 µF) 3.3Vin, 2.5V/3A out
E-mail: [email protected]
http://www.deltaww.com/dcdc
P6
ELECTRICAL CHARACTERISTICS CURVES
Figure 19: Typical transient response to step load change at
2.5A/μS from 100% to 0% of Io, max at 5Vin, 0.6Vout (200uS/div)
(Cout = 47uF ceramic).top trace:Vout,0.1V/div;bottom
trace:Iout:2A/div.
Figure 20: Typical transient response to step load change at
2.5A/μS from 0% to 100% of Io, max at 5Vin, 0.6Vout (200uS/div
) (Cout = 47uF ceramic).top trace:Vout,0.1V/div;bottom
trace:Iout:2A/div.
Figure 21: Typical transient response to step load change at
2.5A/μS from 100% to 0% of Io, max at 5Vin, 1.2Vout (200uS/div)
(Cout = 47uF ceramic).top trace:Vout,0.1V/div;bottom
trace:Iout:2A/div.
Figure 22: Typical transient response to step load change at
2.5A/μS from 0% to 100% of Io, max at 5Vin, 1.2Vout (200uS/div)
(Cout = 47uF ceramic).top trace:Vout,0.1V/div;bottom
trace:Iout:2A/div.
DS_DCT04S0A0S03NFA_05292012
E-mail: [email protected]
http://www.deltaww.com/dcdc
P7
Electrical Characteristics Curves (con.)
Figure 23: Typical transient response to step load change at
2.5A/μS from 100% to 0% of Io, max at 5Vin, 1.8Vout (200uS/div)
(Cout = 47uF ceramic).top trace:Vout,0.1V/div;bottom
trace:Iout:2A/div.
Figure 24: Typical transient response to step load change at
2.5A/μS from 0% to 100% of Io, max at 5Vin, 1.8Vout (200uS/div)
(Cout = 47uF ceramic).top trace:Vout,0.1V/div;bottom
trace:Iout:2A/div.
Figure 25: Typical transient response to step load change at
2.5A/μS from 100% to 0% of Io, max at 5Vin, 3.3Vout (200uS/div)
(Cout = 47uF ceramic).top trace:Vout,0.1V/div;bottom
trace:Iout:2A/div.
Figure 26: Typical transient response to step load change at
2.5A/μS from 0% to 100% of Io, max at 5Vin, 3.3Vout (200uS/div)
(Cout = 47uF ceramic).top trace:Vout,0.1V/div;bottom
trace:Iout:2A/div.
DS_DCT04S0A0S03NFA_05292012
E-mail: [email protected]
http://www.deltaww.com/dcdc
P8
Figure 27: Output short circuit current 5Vin, 3.3Vout(10mS/div)
Figure 28:Tracking at 5Vin, 3.3V/3A out(1mS/div), tracking
Top trace:Vout,0.5V/div;Bottom trace:Iout,5A/div
voltage=4V,top trace:Vseq,1V/div;bottom trace:Vout,1V/div
DS_DCT04S0A0S03NFA_05292012
E-mail: [email protected]
http://www.deltaww.com/dcdc
P9
DESIGN CONSIDERATIONS
TEST CONFIGURATIONS
Input Source Impedance
To maintain low noise and ripple at the input voltage, it is
critical to use low ESR capacitors at the input to the
module. A highly inductive source can affect the stability
of the module. An input capacitance must be placed close
to the modules input pins to filter ripple current and ensure
module stability in the presence of inductive traces that
supply the input voltage to the module.
Figure 29: Input reflected-ripple test setup
Vo
1uF
10uF
SCOPE
tantalum ceramic
Resistive
Load
GND
Note: Use a 10μF tantalum and 1μF capacitor. Scope
measurement should be made using a BNC connector.
Figure 30: Peak-peak output noise and startup transient
measurement test setup.
VI
Vo
GND
Figure 31: Output voltage and efficiency measurement test
setup
Note: All measurements are taken at the module terminals.
When the module is not soldered (via socket), place
Kelvin connections at module terminals to avoid
measurement errors due to contact resistance.
(
Vo  Io
)  100 %
Vi  Ii
DS_DCT04S0A0S03NFA_05292012
E-mail: [email protected]
http://www.deltaww.com/dcdc
P10
DESIGN CONSIDERATIONS (CON.)
FEATURES DESCRIPTIONS
Safety Considerations
Remote On/Off
For safety-agency approval the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standards.
The DCT series power modules have an On/Off pin for
remote On/Off operation. Both positive and negative
On/Off logic options are available in the DCT series power
modules.
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the
input must meet SELV requirements. The power module
has extra-low voltage (ELV) outputs when all inputs are
ELV.
The input to these units is to be provided with a
maximum 6A fuse in the ungrounded lead.
Input Under voltage Lockout
At input voltages below the input under voltage lockout
limit, the module operation is disabled. The module will
begin to operate at an input voltage above the under
For negative logic module, connect an open collector
(NPN) transistor or open drain (N channel) MOSFET
between the On/Off pin and the GND pin (see figure 32).
Negative logic On/Off signal turns the module ON during
the logic high and turns the module OFF during the logic
low. When the negative On/Off function is not used, tie the
pin to GND (module will be On).
For positive logic module, the On/Off pin is pulled high
with an external pull-up 5kΩ resistor (see figure 33).
Positive logic On/Off signal turns the module ON during
logic high and turns the module OFF during logic low. If
the Positive On/Off function is not used, tie the pin to Vin.
(module will be On)
voltage lockout turn-on threshold.
Over-Current Protection
To provide protection in an output over load fault
condition, the unit is equipped with internal over-current
protection. When the over-current protection is triggered,
the unit enters hiccup mode. The units operate normally
once the fault condition is removed.
Vo
V in
I O N /O F F
O n/O ff
RL
Q1
GND
Figure 32: Negaitive remote On/Off implementation
Vo
Vin
Rpullup
I O N /O FF
On/Off
RL
Q1
GND
Figure 33: Positive remote On/Off implementation
Over-Current Protection
To provide protection in an output over load fault
condition, the unit is equipped with internal over-current
protection. When the over-current protection is triggered,
the unit enters hiccup mode. The units operate normally
once the fault condition is removed.
DS_DCT04S0A0S03NFA_05292012
E-mail: [email protected]
http://www.deltaww.com/dcdc
P11
FEATURES DESCRIPTIONS (CON.)
Vo
Remote Sense
RLoad
TRIM
The DCT provide Vo remote sensing to achieve proper
regulation at the load points and reduce effects of
distribution losses on output line. In the event of an open
remote sense line, the module shall maintain local sense
regulation through an internal resistor. The module shall
correct for a total of 0.5V of loss. The remote sense line
impedance shall be < 10.
Distribution Losses
Vo
Vin
Distribution Losses
Sense
Rtrim
GND
Figure 35: Circuit configuration for programming output voltage
using an external resistor
Table 1 provides Rtrim values required for some common
output voltages, By using a 0.5% tolerance trim resistor, set
point tolerance of ±1.5% can be achieved as specified in
the electrical specification.
RL
Table 1
GND
Distribution
FigureLosses
34: Effective
Distribution
Losses
circuit configuration for remote sense
operation
Output Voltage Programming
The output voltage of the DCT can be programmed to any
voltage between 0.6Vdc and 3.3Vdc by connecting one
resistor (shown as Rtrim in Figure 35) between the TRIM
and GND pins of the module. Without this external
resistor, the output voltage of the module is 0.6 Vdc. To
calculate the value of the resistor Rtrim for a particular
output voltage Vo, please use the following equation:
 1.2 
Rtrim  
 k
Vo  0.6 
For example, to program the output voltage of the DCT
module to 1.8Vdc, Rtrim is calculated as follows:
 1.2 
Rtrim  
 k  1K
1.8  0.6 
0.6V
Open
1V
3K
1.2V
2K
1.5V
1.8V
1.333K
1K
2.5V
0.632K
3.3V
0.444K
Certain restrictions apply on the output voltage set point
depending on the input voltage. These are shown in the
Output Voltage vs. Input Voltage Set Point Area plot in
Figure 36. The Upper Limit curve shows that for output
voltages of 3.3V and lower, the input voltage must be lower
than the maximum of 5.5V. The Lower Limit curve shows
that for output voltages of 1.8V and higher, the input voltage
needs to be larger than the minimum of 2.4V.
Figure 36: Output Voltage vs. Input Voltage Set Point Area plot
showing limits where the output voltage can be set for different
input voltages.
DS_DCT04S0A0S03NFA_05292012
E-mail: [email protected]
http://www.deltaww.com/dcdc
P12
FEATURE DESCRIPTIONS (CON.)
When an analog voltage is applied to the SEQ pin, the
output voltage tracks this voltage until the output reaches
Voltage Margining
the set-point voltage. The final value of the SEQ voltage
Output voltage margining can be implemented in the DCT
modules by connecting a resistor, R margin-up, from the Trim
pin to the ground pin for margining-up the output voltage
and by connecting a resistor, R margin-down, from the Trim pin
to the output pin for margining-down. Figure 3 shows the
circuit configuration for output voltage margining. If
unused, leave the trim pin unconnected. A calculation tool
is available from the evaluation procedure which
computes the values of Rmargin-up and Rmargin-down for a
specific output voltage and margin percentage.
Vin
must be set higher than the set-point voltage of the
module. The output voltage follows the voltage on the
SEQ pin on a one-to-one basis. By connecting multiple
modules together, multiple modules can track their output
voltages to the voltage applied on the SEQ pin.
For proper voltage sequencing, first, input voltage is
applied to the module. The On/Off pin of the module is
left unconnected (or tied to GND for negative logic
modules or tied to VIN for positive logic modules) so that
Vo
Rmargin-down
Q1
the module is ON by default. After applying input voltage
to the module, a minimum 10msec delay is required
On/Off Trim
Rtrim
Rmargin-up
before applying voltage on the SEQ pin. This delay gives
Q2
the module enough time to complete its internal power-up
GND
soft-start cycle. During the delay time, the SEQ pin
should be held close to ground (nominally 50mV ± 20
Figure 37: Circuit configuration for output voltage margining
Output Voltage Sequencing
The DCT modules include a sequencing feature,
EZ-SEQUENCE that enables users to implement various
types of output voltage sequencing in their applications.
This is accomplished via an additional sequencing pin.
When not using the sequencing feature, either tie the SEQ
pin to VIN or leave it unconnected.
mV). This is required to keep the internal op-amp out of
saturation thus preventing output overshoot during the
start of the sequencing ramp. By selecting resistor R1
(see Figure. 38) according to the following equation
 24950 
R1  

Vin  0.05 
The voltage at the sequencing pin will be 50mV when the
sequencing signal is at zero.
DS_DCT04S0A0S03NFA_05292012
E-mail: [email protected]
http://www.deltaww.com/dcdc
P13
FEATURE DESCRIPTIONS (CON.)
Monotonic Start-up and Shutdown
After the 10msec delay, an analog voltage is applied to
The DCT 3A modules have monotonic start-up and
the SEQ pin and the output voltage of the module will
shutdown behavior for any combination of rated input
track this voltage on a one-to-one volt bases until the
voltage, output current and operating temperature range.
output reaches the set-point voltage. To initiate
simultaneous shutdown of the modules, the SEQ pin
voltage is lowered in a controlled manner. The output
voltage of the modules tracks the voltages below their
set-point voltages on a one-to-one basis. A valid input
voltage must be maintained until the tracking and output
voltages reach ground potential.
When using the EZ-SEQUENCETM feature to control
start-up of the module, pre-bias immunity during startup is
disabled. The pre-bias immunity feature of the module
relies on the module being in the diode-mode during
start-up. When using the EZ-SEQUENCETM feature,
modules goes through an internal set-up time of 10msec,
and will be in synchronous rectification mode when the
voltage at the SEQ pin is applied. This will result in the
module sinking current if a pre-bias voltage is present at
the output of the module.
Figure 38: Circuit showing connection of the sequencing signal to
the SEQ pin.
DS_DCT04S0A0S03NFA_05292012
Simultaneous
E-mail: [email protected]
http://www.deltaww.com/dcdc
P14
THERMAL CONSIDERATIONS
THERMAL CURVES
Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.
Figure 40: Temperature measurement location
The allowed maximum hot spot temperature is defined at 109℃
Output Current (A)
DCT04S0A0S03 Output Current vs. Ambient Temperature and Air Velocity
@Vin=5V Vout=2.5V~3.3V (Either Orientation)
3.5
The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel.
3.0
Natural
Convection
2.5
2.0
Thermal Derating
1.5
Heat can be removed by increasing airflow over the
module. To enhance system reliability, the power
module should always be operated below the maximum
operating temperature. If the temperature exceeds the
maximum module temperature, reliability of the unit may
be affected.
PWB
FANCING PWB
1.0
0.5
0.0
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (℃)
Figure 41: Output current vs. ambient temperature and air
velocity@Vin=5V, Vout=2.5V~3.3V(Either Orientation)
MODULE
Output Current (A)
DCT04S0A0S03 Output Current vs. Ambient Temperature and Air Velocity
@Vin=3.3V Vout=0.6V~1.8V (Either Orientation)
3.5
3.0
Natural
Convection
2.5
50.8(2.00")
AIR VELOCITY
AND AMBIENT
TEMPERATURE
SURED BELOW
THE MODULE
2.0
1.5
AIR FLOW
1.0
0.5
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)
0.0
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (℃)
Figure 39: Wind tunnel test setup
DS_DCT04S0A0S03NFA_05292012
Figure 42: Output current vs. ambient temperature and air
velocity@Vin=3.3V, Vout=0.6V~1.8V(Either Orientation)
E-mail: [email protected]
http://www.deltaww.com/dcdc
P15
PICK AND PLACE LOCATION
RECOMMENDED PAD LAYOUT
SURFACE-MOUNT TAPE & REEL
DS_DCT04S0A0S03NFA_05292012
E-mail: [email protected]
http://www.deltaww.com/dcdc
P16
LEAD (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE
Note: The temperature refers to the pin of DCT, measured on the pin Vout joint.
LEAD FREE (SAC) PROCESS RECOMMEND TEMP. PROFILE
Temp.
Peak Temp. 240 ~ 245 ℃
220℃
Ramp down
max. 4℃ /sec.
200℃
150℃
Preheat time
90~120 sec.
Time Limited 75 sec.
above 220℃
Ramp up
max. 3℃ /sec.
25℃
Time
Note: The temperature refers to the pin of DCT, measured on the pin Vout joint.
DS_DCT04S0A0S03NFA_05292012
E-mail: [email protected]
http://www.deltaww.com/dcdc
P17
MECHANICAL DRAWING
DS_DCT04S0A0S03NFA_05292012
E-mail: [email protected]
http://www.deltaww.com/dcdc
P18
PART NUMBERING SYSTEM
DCT
04
S
0A0
S
03
N
Product
Series
Input
Voltage
Numbers
of Outputs
Output
Voltage
Package
Type
Output
Current
On/Off
logic
DCT - 3A
DCS- 6A
DCM - 12A
DCL - 20A
04 2.4~5.5V
12 –
4.5~14V
S - Single
0A0 S - SMD
Programmable
03-3A
06 - 6A
12 - 12A
20 - 20A
F
N- negative
P- positive
A
Option Code
F- RoHS 6/6
(Lead Free)
A - Standard Function
MODEL LIST
Model Name
Packaging
Input Voltage
Output Voltage
Output Current
Efficiency
5.0Vin, 3.3Vdc @ 3A
DCT04S0A0S03NFA
SMD
2.4 ~ 5.5Vdc
0.6V~ 3.3Vdc
3A
96.5%
CONTACT: www.deltaww.com/dcdc
USA:
Telephone:
East Coast: (888) 335 8201
West Coast: (888) 335 8208
Fax: (978) 656 3964
Email: [email protected]
Europe:
Telephone:+31-20-655-0967
Fax: +31-20-655-0999
Email: [email protected]
Asia & the rest of world:
Telephone: +886 3 4526107
Ext. 6220~6224
Fax: +886 3 4513485
Email: [email protected]
WARRANTY
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available
upon request from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by
Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use.
No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right
to revise these specifications at any time, without notice .
DS_DCT04S0A0S03NFA_05292012
E-mail: [email protected]
http://www.deltaww.com/dcdc
P19
Similar pages