EBMPAPST K3G200-AD Ec diagonal compact module Datasheet

EC Diagonal Compact Modules
Series K3G200-AD Ø 200 mm
Bearing
Ingress protection rating
UL
Chart
506
Mass
M3G055-BI
Temperature range (1)
K3G200-AD11-02
Max back pressure
547
Current draw (1)
M3G055-BI
Speed (1)
K3G200-AD21-01
Power input (1)
cfm
Frequency
Motor
Voltage range
Type
Voltage
Nominal Data
VAC
VAC
Hz
W
rpm
A
in. H20
°C
lbs
230V
200...240
50/60
80
3100
0.7
0.884
-25...60
4.41
Ball
IP54
Yes
A
115V
100...130
50/60
65
2850
1.0
0.723
-25...60
4.41
Ball
IP54
Yes
B
Phase
Air flow
Highlights:
– Control Input: 0-10 VDC/PWM
– Output: 10 VDC, max 1.1 mA
– Tach Output
– Over-temperature protected electronics/motor
– Soft start, motor current limit
– Locked rotor protection
Material: Impeller: PA composite
Housing: PP composite
Mounting position: Any
Condensate discharge holes: None, open rotor
Direction of rotation: Clockwise, seen on rotor
1~
1~
(1) Nominal data at maximum load.
Curves
in. wg
Air performance measured as per:
ISO 5801, Installation category
A, without protection against
accidental contact.
1.60
1.40
1.20
Suction-side noise levels: LWA as
per ISO 13347, LPA measured at
1m distance to fan axis.
A
1.00
The values given are valid
under the measuring conditions
mentioned and may vary accoring
to the actual installation situation.
4
B
0.80
8
With any deviation to the standard
set-up, the specific values have
to be checked and reviewed once
installed or fitted.
3
0.60
7
0.40
6
pfs
0.20
0.00
0
q
100
200
300
400
2
For detailed information on the
measuring set-up, please contact
ebm-papst.
5
500
1
cfm
600
n
Pe
I
LpAin
LwAin
rpm
W
A
dB(A)
dB(A)
A
1
3160
69
0.63
64
72
A
2
3120
75
0.68
62
70
A
3
3100
80
0.70
61
69
A
4
3100
76
0.69
61
69
A
5
2945
59
0.96
62
70
A
6
2885
62
1.00
61
69
A
7
2850
65
1.00
59
68
A
8
2845
64
1.00
59
68
A
9
A
10
A
11
A
12
A
13
A
14
A
15
A
16
K3G200-ADXX-XX
Dimensions shown in millimeters
Connection screen
Conn.
Designation
Color
Function / assignment
CON10
L
black
Power supply for voltage range refer to rating plate
CON11
N
blue
Neutral conductor
CON12
PE
green/yellow
Protective earth
1
GND
blue
GND - Connection for control interface
2
0- 10V PWM
yellow
Control input 0 - 10 V or PWM, electrically isolated
3
10V/ max 1.1mA
red
Voltage output 10 V / 1.1 mA, electrically isolated
4
Tach
white
Tach output: open collector, 1 pulse per revolution, electrically isolated, Isink max = 10 mA