MPD D103VHI Miniature, 1w sip ultra-high isolation dc/dc converter Datasheet

D100VHI Series
Miniature, 1W SIP
Ultra-High Isolation
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 1W Output Power
• 6.0 kVDC Isolation
• Miniature SIP Case
• Single & Dual Outputs
• Miniature SIP Case
• 12 Standard Models
• 2.0 MH MTBF
• Industry Standard Pin-Out
Input
Parameter
Input Voltage Range
Conditions
Min.
Typ.
Max.
5 VDC Input
4.5
5.0
5.5
12 VDC Input
10.8
12.0
13.2
Input Filter
VDC
Internal Capacitor
Reverse Polarity Input Current
0.3
A
Units
Output
Parameter
Conditions
Min.
Typ.
Max.
±1.0
±3.0
%
Dual Output , Balanced Loads
±0.1
±1.0
%
For Vin Change of 1%
±1.2
±1.5
%
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation (Note 1)
See Model Selection Guide
Ripple & Noise (20 MHz) (Note 2)
Ripple & Noise (20 MHz)
100
Over Line, Load & Temp.
Ripple & Noise (20 MHz)
Output Power Protection
150
mV P - P
200
mV P - P
5
mV rms
±0.02
%/°C
Max.
Units
120
Temperature Coefficient
%
±0.01
Output Short Circuit
RoHS Compliant
Units
Momentary (0.5 Sec.)
General
Parameter
Conditions
Isolation Voltage
Isolation Test Voltage
Min.
Typ.
60 Seconds
6,000
VDC
Flash Tested For 1 Sec
6,600
VDC
Isolation Resistance
500 VDC
Isolation Capacitance
10
100 kHz, 1V
Switching Frequency
GΩ
15
20
pF
50
80
100
kHz
Min.
Typ.
Max.
Units
+25
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
-40
+70
°C
Operating Temperature Range
Case
-40
+90
°C
-40
+125
°C
95
%
Storage Temperature Range
MicroPower Direct
Cooling
292 Page Street
Suite D
Stoughton, MA 02072
USA
Humidity
Free Air Convection
RH, Non-condensing
Physical
Case Size
0.87 x 0.49 x 0.30 Inches (22.0 x 12.5 x 7.5 mm)
Case Material
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Non-Conductive Black Plastic (UL94-V0)
Weight
0.13 Oz (3.9g)
Reliability Specifications
Parameter
MTBF
Conditions
Min.
MIL HDBK 217F, 25°C, Gnd Benign
Typ.
Max.
2.0
Units
MHours
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Conditions
Min.
Typ.
Max.
5 VDC Input
-0.7
9.0
12 VDC Input
-0.7
18.0
Units
VDC
1.5 mm From Case For 10 Sec
260
°C
All Models
650
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Output
Load
Voltage
Current
Current Regulation
Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max)
Current (mA)
Efficiency
(%, Typ)
Fuse Rating
Slow-Blow
(mA)
Nominal
Range
D101VHI
5
4.5 - 5.5
303
55
5.0
200.0
4.0
10
66
500
D102VHI
5
4.5 - 5.5
291
55
12.0
80.0
2.0
8
66
500
D103VHI
5
4.5 - 5.5
295
55
15.0
65.0
1.0
8
66
500
D104VHI
5
4.5 - 5.5
303
55
±5.0
±100.0
±2.0
10
66
500
D105VHI
5
4.5 - 5.5
267
55
±12.0
±40.0
±1.0
8
72
500
D106VHI
5
4.5 - 5.5
287
55
±15.0
±35.0
±1.0
8
73
500
D111VHI
12
10.8 - 13.2
126
30
5.0
200.0
4.0
10
66
200
D112VHI
12
10.8 - 13.2
121
30
12.0
80.0
2.0
8
66
200
D113VHI
12
10.8 - 13.2
123
30
15.0
65.0
1.0
8
66
200
D114VHI
12
10.8 - 13.2
126
30
±5.0
±100.0
±2.0
10
66
200
D115VHI
12
10.8 - 13.2
108
30
±12.0
±40.0
±1.0
8
74
200
D116VHI
12
10.8 - 13.2
117
30
±15.0
±35.0
±1.0
8
75
200
Notes:
1. Output load regulation is specified for a load change of 20%
to 100%.
2. When measuring output ripple, it is recomended that an external 0.33 µF ceramic capacitor be placed from the +Vout pin to
the -Vout pin for single output units and from each output to
common for dual output units.
3. Operation at no-load will not damage these units. However,
they may not meet all specifications.
4. Dual output units may be connected to provide a 10 VDC, 24
VDC or 30 VDC output. To do this, connect the load across the
positive (+Vout) and negative (-Vout) outputs and float the
output common.
5. It is recommended that a fuse be used on the input of a power
supply for protection. See the table above for the correct rating.
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
1
+Vin
+Vin
2
-Vin
-Vin
5
-Vout
-Vout
6
No Pin
Common
7
+Vout
+Vout
NC: No Connection
Capacitive Load
Single Output
µF Max
Dual Output
µF Max
680
±220
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages