Omron E2A-S08KS02-M1-C1 Cylindrical proximity sensor Datasheet

Cylindrical Proximity Sensor
E2A
Safe Mounting with Greater
Sensing Distance
• Ensures a sensing distance approximately 1.5 to 2
times larger than that of any conventional OMRON
Sensor.
• Problems such as the collision of workpieces are
eliminated.
• Full range of standard sizes (M8, M12, M18 and
M30; both long and short barrels)
• Modular construction simplifies customization.
<READ AND UNDERSTAND THIS CATALOG>
Please read and understand this catalog before purchasing
the products. Please consult your OMRON representative if
you have any questions or comments.
Ordering Information
Size
M8
Shielded
Sensing
distance
2.0 mm
Connection
Pre-wired
Body
material
Stainless
steel
Thread length
Output
(overall length) configuration
27 (40)
Stainless
steel
Brass
PNP
E2A-S08KS02-WP-B1 2M
E2A-S08KS02-WP-B2 2M
E2A-S08KS02-WP-C1 2M
E2A-S08KS02-WP-C2 2M
PNP
E2A-S08LS02-WP-B1 2M
E2A-S08LS02-WP-B2 2M
NPN
E2A-S08LS02-WP-C1 2M
E2A-S08LS02-WP-C2 2M
27 (43)
PNP
E2A-S08KS02-M1-B1
E2A-S08KS02-M1-B2
NPN
E2A-S08KS02-M1-C1
E2A-S08KS02-M1-C2
49 (65)
PNP
E2A-S08LS02-M1-B1
E2A-S08LS02-M1-B2
NPN
E2A-S08LS02-M1-C1
E2A-S08LS02-M1-C2
27 (43)
PNP
E2A-M08KS02-M1-B1
E2A-M08KS02-M1-B2
NPN
E2A-M08KS02-M1-C1
E2A-M08KS02-M1-C2
PNP
E2A-M08LS02-M1-B1
E2A-M08LS02-M1-B2
NPN
E2A-M08LS02-M1-C1
E2A-M08LS02-M1-C2
27 (39)
PNP
E2A-S08KS02-M5-B1
E2A-S08KS02-M5-B2
NPN
E2A-S08KS02-M5-C1
E2A-S08KS02-M5-C2
49 (61)
PNP
E2A-S08LS02-M5-B1
E2A-S08LS02-M5-B2
NPN
E2A-S08LS02-M5-C1
E2A-S08LS02-M5-C2
E2A-S08KN04-WP-B2 2M
49 (65)
M8 connector (3- Stainless
pin)
steel
Non-shielded
4.0 mm
Pre-wired
M12 connector
Stainless
steel
Stainless
steel
Brass
27 (40)
PNP
E2A-S08KN04-WP-B1 2M
NPN
E2A-S08KN04-WP-C1 2M
E2A-S08KN04-WP-C2 2M
49 (62)
PNP
E2A-S08LN04-WP-B1 2M
E2A-S08LN04-WP-B2 2M
NPN
E2A-S08LN04-WP-C1 2M
E2A-S08LN04-WP-C2 2M
27 (43)
PNP
E2A-S08KN04-M1-B1
E2A-S08KN04-M1-B2
NPN
E2A-S08KN04-M1-C1
E2A-S08KN04-M1-C2
49 (65)
PNP
E2A-S08LN04-M1-B1
E2A-S08LN04-M1-B2
NPN
E2A-S08LN04-M1-C1
E2A-S08LN04-M1-C2
27 (43)
49 (65)
M8 connector (3- Stainless
pin)
steel
Operation mode NC
NPN
49 (62)
M12 connector
Operation mode NO
27 (39)
49 (61)
PNP
E2A-M08KN04-M1-B1
E2A-M08KN04-M1-B2
NPN
E2A-M08KN04-M1-C1
E2A-M08KN04-M1-C2
PNP
E2A-M08LN04-M1-B1
E2A-M08LN04-M1-B2
NPN
E2A-M08LN04-M1-C1
E2A-M08LN04-M1-C2
PNP
E2A-S08KN04-M5-B1
E2A-S08KN04-M5-B2
NPN
E2A-S08KN04-M5-C1
E2A-S08KN04-M5-C2
PNP
E2A-S08LN04-M5-B1
E2A-S08LN04-M5-B2
NPN
E2A-S08LN04-M5-C1
E2A-S08LN04-M5-C2
E2A Cylindrical Proximity Sensor
1
Size
M12
Sensing
distance
Shielded
4.0 mm
Connection
Pre-wired
Body
material
Brass
Thread length
Output
(overall length) configuration
34 (50)
Non-shielded
8.0 mm
Pre-wired
Brass
Brass
PNP
E2A-M12KS04-WP-B1 2M
E2A-M12KS04-WP-B2 2M
E2A-M12KS04-WP-C1 2M
E2A-M12KS04-WP-C2 2M
PNP
E2A-M12LS04-WP-B1 2M
E2A-M12LS04-WP-B2 2M
NPN
E2A-M12LS04-WP-C1 2M
E2A-M12LS04-WP-C2 2M
34 (48)
PNP
E2A-M12KS04-M1-B1
E2A-M12KS04-M1-B2
NPN
E2A-M12KS04-M1-C1
E2A-M12KS04-M1-C2
56 (70)
PNP
E2A-M12LS04-M1-B1
E2A-M12LS04-M1-B2
NPN
E2A-M12LS04-M1-C1
E2A-M12LS04-M1-C2
PNP
E2A-M12KN08-WP-B1 2M
E2A-M12KN08-WP-B2 2M
NPN
E2A-M12KN08-WP-C1 2M
E2A-M12KN08-WP-C2 2M
34 (50)
56 (72)
M12 connector
Brass
34 (48)
56 (70)
M18
Shielded
8.0 mm
Pre-wired
Brass
39 (59)
Non-shielded
16.0 mm
Pre-wired
Brass
Brass
Brass
Shielded
15.0 mm
Pre-wired
Brass
Non-shielded
20.0 mm
Pre-wired
Brass
Brass
30.0 mm
20.0 mm
M12 connector
Brass
30.0 mm
E2A-M12LN08-WP-C2 2M
PNP
E2A-M12KN08-M1-B1
E2A-M12KN08-M1-B2
NPN
E2A-M12KN08-M1-C1
E2A-M12KN08-M1-C2
PNP
E2A-M12LN08-M1-B1
E2A-M12LN08-M1-B2
NPN
E2A-M12LN08-M1-C1
E2A-M12LN08-M1-C2
E2A-M18KS08-WP-B1 2M
E2A-M18KS08-WP-B2 2M
E2A-M18KS08-WP-C2 2M
PNP
E2A-M18LS08-WP-B1 2M
E2A-M18LS08-WP-B2 2M
NPN
E2A-M18LS08-WP-C1 2M
E2A-M18LS08-WP-C2 2M
39 (53)
PNP
E2A-M18KS08-M1-B1
E2A-M18KS08-M1-B2
NPN
E2A-M18KS08-M1-C1
E2A-M18KS08-M1-C2
61 (75)
PNP
E2A-M18LS08-M1-B1
E2A-M18LS08-M1-B2
NPN
E2A-M18LS08-M1-C1
E2A-M18LS08-M1-C2
PNP
E2A-M18KN16-WP-B1 2M
E2A-M18KN16-WP-B2 2M
NPN
E2A-M18KN16-WP-C1 2M
E2A-M18KN16-WP-C2 2M
39 (59)
39 (53)
44 (64)
PNP
E2A-M18LN16-WP-B1 2M
E2A-M18LN16-WP-B2 2M
NPN
E2A-M18LN16-WP-C1 2M
E2A-M18LN16-WP-C2 2M
PNP
E2A-M18KN16-M1-B1
E2A-M18KN16-M1-B2
NPN
E2A-M18KN16-M1-C1
E2A-M18KN16-M1-C2
PNP
E2A-M18LN16-M1-B1
E2A-M18LN16-M1-B2
NPN
E2A-M18LN16-M1-C1
E2A-M18LN16-M1-C2
PNP
E2A-M30KS15-WP-B1 2M
E2A-M30KS15-WP-B2 2M
NPN
E2A-M30KS15-WP-C1 2M
E2A-M30KS15-WP-C2 2M
PNP
E2A-M30LS15-WP-B1 2M
E2A-M30LS15-WP-B2 2M
NPN
E2A-M30LS15-WP-C1 2M
E2A-M30LS15-WP-C2 2M
44 (58)
PNP
E2A-M30KS15-M1-B1
E2A-M30KS15-M1-B2
NPN
E2A-M30KS15-M1-C1
E2A-M30KS15-M1-C2
66 (80)
PNP
E2A-M30LS15-M1-B1
E2A-M30LS15-M1-B2
NPN
E2A-M30LS15-M1-C1
E2A-M30LS15-M1-C2
44 (64)
(See note.)
PNP
E2A-M30KN20-WP-B1 2M
E2A-M30KN20-WP-B2 2M
NPN
E2A-M30KN20-WP-C1 2M
E2A-M30KN20-WP-C2 2M
66 (86)
PNP
E2A-M30LN30-WP-B1 2M
E2A-M30LN30-WP-B2 2M
66 (86)
M12 connector
E2A-M12LN08-WP-B2 2M
E2A-M12LN08-WP-C1 2M
E2A-M18KS08-WP-C1 2M
61 (75)
M30
E2A-M12LN08-WP-B1 2M
PNP
61 (81)
M12 connector
PNP
NPN
NPN
61 (81)
M12 connector
Operation mode NC
NPN
56 (72)
M12 connector
Operation mode NO
NPN
E2A-M30LN30-WP-C1 2M
E2A-M30LN30-WP-C2 2M
44 (58)
(See note.)
PNP
E2A-M30KN20-M1-B1
E2A-M30KN20-M1-B2
NPN
E2A-M30KN20-M1-C1
E2A-M30KN20-M1-C2
66 (80)
PNP
E2A-M30LN30-M1-B1
E2A-M30LN30-M1-B2
NPN
E2A-M30LN30-M1-C1
E2A-M30LN30-M1-C2
Note: M30 non-shielded Models with double sensing distance and short barrels cannot be mounted due to the necessary separation distance from
the surrounding metal. Standard sensing models are thus available.
2
E2A Cylindrical Proximity Sensor
■ Model Number Legend
E2A@-@@@@@-@-@@-@@
1
2
3 4 5 6 7
8
9 10 11 12
Example: E2A-M12LS04-M1-B1
E2A-M08KN04-WP-B1 5M
Standard, M12, long barrel, shielded, Sn=4 mm, M12 connector, PNP-NO
Standard, M8, short barrel, non-shielded, Sn=4 mm, pre-wired PVC cable, PNP-NO, cable length=5 m
1. Basic name
E2A
2. Sensing technology
Blank:
Standard double distance
3. Housing shape and material
M:
Cylindrical, metric threaded, brass
S:
Cylindrical, metric threaded, stainless steel
4. Housing size
8. Kind of connection
WP:
Pre-wired, PVC
M1:
M12 connector (4-pole)
M3:
M8 connector (4-pole)
M5:
M8 connector (3-pole)
9. Power source and output
B:
DC, 3-wire, PNP open collector
C:
DC, 3-wire, NPN open collector
08:
8 mm
D:
DC, 2-wire
12:
12 mm
E:
DC, 3-wire, NPN voltage output
18:
18 mm
F:
DC, 3-wire, PNP voltage output
30:
30 mm
5. Barrel length
10.Operation mode
1:
Normally open (NO)
2:
Normally closed (NC)
K:
Standard length
L:
Long body
11.Specials (e.g., cable material, oscillating frequency)
S:
Shielded
12.Cable length
N:
Non-shielded
6. Shield
7. Sensing distance
Blank:
Connector type
Numeral: Cable type
Numeral: Sensing distance: e.g. 02=2 mm, 16=16 mm
E2A Cylindrical Proximity Sensor
3
Specifications
■ DC 3-wire Models
Size
M8
Type
Item
M12
Shielded
Non-shielded
Shielded
Non-shielded
E2A-M08@S02-M1-B1
E2A-M08@S02-M1-B2
E2A-M08@S02-M1-C1
E2A-M08@S02-M1-C2
E2A-S08@S02-@@-B1
E2A-S08@S02-@@-B2
E2A-S08@S02-@@-C1
E2A-S08@S02-@@-C2
E2A-M08@N04-M1-B1
E2A-M08@N04-M1-B2
E2A-M08@N04-M1-C1
E2A-M08@N04-M1-C2
E2A-S08@N04-@@-B1
E2A-S08@N04-@@-B2
E2A-S08@N04-@@-C1
E2A-S08@N04-@@-C2
E2A-M12@S04-@@-B1
E2A-M12@S04-@@-B2
E2A-M12@S04-@@-C1
E2A-M12@S04-@@-C2
E2A-M12@N08-@@-B1
E2A-M12@N08-@@-B2
E2A-M12@N08-@@-C1
E2A-M12@N08-@@-C2
Sensing distance
2 mm ± 10%
4 mm ± 10%
4 mm ± 10%
8 mm ± 10%
Setting distance
0 to 1.6 mm
0 to 3.2 mm
0 to 3.2 mm
0 to 6.4 mm
Differential travel
10% max. of sensing distance
Target
Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target (mild steel ST37)
8×8×1 mm
12×12×1 mm
12×12×1 mm
24×24×1 mm
Response frequency (See note 1.)
1,500 Hz
1,000 Hz
1,000 Hz
800 Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Current consumption (DC 3-wire)
10 mA max.
Output type
-B models: PNP open collector
-C models: NPN open collector
Control
output
Load current
(See note 2.)
200 mA max. (32 VDC max.)
Residual voltage
2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator
Operation indicator (Yellow LED)
Operation mode
(with sensing object approaching)
-B1/-C1 models: NO
-B2/-C2 models: NC
For details, refer to the timing charts.
Protection circuit
Power source circuit reverse polarity protection,
Surge suppressor, Short-circuit protection
Ambient air temperature
Temperature influence (See note 2.)
Ambient humidity
Output reverse polarity protection, Power source
circuit reverse polarity protection, Surge suppressor, Short-circuit protection
Operating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation)
±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C
±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C
Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence
±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance
50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
500 m/s2, 10 times each in X, Y and Z directions
Standard and listings (See note 3.)
IEC60529: IP67, Degree of protection
EN60947-5-2: EMC
Connection method
-WP models: Pre-wired models (Standard length: 2 m)
-M1 models: M12 4-pin connector models
-M5 models: M8 3-pin connector models
Weight
(packaged)
Material
1,000 m/s2, 10 times each in X, Y and Z directions
Pre-wired model
Approx. 65 g
Approx. 85 g
M12 connector model
M12 connector models: Approx. 20 g
M8 connector models: Approx. 15 g
Approx. 35 g
Case
Stainless steel or brass-nickel plated
Brass-nickel plated
Sensing surface
PBT
Cable
PVC
Clamping nut
Brass-nickel plated
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between −40°C and −25°C and a power voltage between 30 and 32 VDC, use a load
current of 100 mA max.,
3. For USA and CANADA : use class 2 circuit only.
4
E2A Cylindrical Proximity Sensor
■ DC 3-wire Models
Size
M18
Type
Item
M30
Shielded
Non-shielded
Shielded
Non-shielded
Non-shielded
E2A-M18@S08-@@-B1
E2A-M18@S08-@@-B2
E2A-M18@S08-@@-C1
E2A-M18@S08-@@-C2
E2A-M18@N16-@@-B1
E2A-M18@N16-@@-B2
E2A-M18@N16-@@-C1
E2A-M18@N16-@@-C2
E2A-M30@S15-@@-B1
E2A-M30@S15-@@-B2
E2A-M30@S15-@@-C1
E2A-M30@S15-@@-C2
E2A-M30KN20-@@-B1
E2A-M30KN20-@@-B2
E2A-M30KN20-@@-C1
E2A-M30KN20-@@-C2
E2A-M30LN30-@@-B1
E2A-M30LN30-@@-B2
E2A-M30LN30-@@-C1
E2A-M30LN30-@@-C2
Sensing distance
8 mm±10%
16 mm±10%
15 mm±10%
20 mm±10%
30 mm±10%
Setting distance
0 to 6.4 mm
0 to 12.8 mm
0 to 12 mm
0 to 16 mm
0 to 24 mm
Differential travel
10% max. of sensing distance
Target
Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target
(mild steel ST37)
24×24×1 mm
48×48×1 mm
45×45×1 mm
60×60×1 mm
90×90×1 mm
Response frequency
(See note 1.)
500 Hz
400 Hz
250 Hz
100 Hz
100 Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Current consumption (DC
3-wire)
10 mA max.
Output type
-B models: PNP open collector
-C models: NPN open collector
Control
output
Load current (See 200 mA max. (32 VDC max.)
note 2.)
Residual voltage
2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator
Operation indicator (Yellow LED)
Operation mode
(with sensing object approaching)
-B1/-C1 models: NO
-B2/-C2 models: NC
For details, refer to the timing charts.
Protection circuit
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit
protection
Ambient air temperature
Operating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation)
Temperature influence (See ±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C
note 2.)
±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C
Operating: 35% to 95%, Storage: 35% to 95%
Ambient humidity
Voltage influence
±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance
50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
1,000 m/s2, 10 times each in X, Y and Z directions
Standard and listings
(See note 3.)
IEC60529: IP67, Degree of protection
EN60947-5-2: EMC
Connection method
-WP models: Pre-wired models (Standard length: 2 m)
-M1 models: M12 4-pin connector models
-M5 models: M8 3-pin connector models
Weight
(packaged)
Pre-wired model
Approx. 160 g
Approx. 280 g
Approx. 280 g
Approx. 370 g
M12 connector
model
Approx. 70 g
Approx. 200 g
Approx. 200 g
Approx. 260 g
Material Case
Brass-nickel plated
Sensing surface
PBT
Cable
PVC
Clamping nut
Brass-nickel plated
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load
current of 100 mA max.
3. For USA and CANADA : use class 2 circuit only.
E2A Cylindrical Proximity Sensor
5
Engineering Data
Operating Range (Typical)
Non-shielded Models
18
Sensing distance X (mm)
Sensing distance X (mm)
Shielded Models
E2A-M30@S15
16
14
Y
12
X
E2A-M18@S08
10
8
E2A-M12@S04
E2A-S08@S02/
E2A-M08@S02
6
4
35
E2A-M30LN30
30
Y
25
X
E2A-M30KN20
20
E2A-M18@N16
15
E2A-M12@N08
10
E2A-S08@N04/
E2A-M08@N04
5
2
0
−30
−20
−10
0
10
20
0
−50 −40 −30 −20 −10
30
0
10
20
30
40
50
Distance Y (mm)
Distance Y (mm)
Influence of Sensing Object Size and Materials
2.5
@d
X
t = 1 mm
Iron
2.0
Stainless steel (SUS303)
1.5
Brass
1.0
Aluminum
E2A-M12@S04
E2A-M18@S08
Sensing distance X (mm)
Sensing distance X (mm)
E2A-S08@S02/M08@S02
Sensing distance X (mm)
Shielded Models
5.0
@d
X
t = 1 mm
Iron
4.0
Stainless steel
(SUS303)
3.0
Brass
Aluminum
2.0
Copper
Copper
8.0
Iron
7.0
6.0
5.0
Brass
4.0
Aluminum
3.0
2.0
0.5
Stainless steel (SUS303)
Copper
@d
X
1.0
t = 1 mm
1.0
0
5
10
15
20
25
Side length of sensing object d (mm)
0
5
Sensing distance X (mm)
E2A-M30@S15
20
@d
X
t = 1 mm
16
Iron
12
Stainless steel (SUS303)
8
Brass
Aluminum
Copper
4
0
10
20
30
40
50
60
70
80
Side length of sensing object d (mm)
6
10
15
20
25
30
35
Side length of sensing object d (mm)
E2A Cylindrical Proximity Sensor
0
10
20
30
40
50
60
Side length of sensing object d (mm)
Non-shielded Models
@d
X
E2A-M12@N08
t = 1 mm
Iron
4.0
Stainless steel (SUS303)
3.0
Brass
2.0
Aluminum
E2A-M18@N16
10
@d
X
t = 1 mm
Iron
8
6
Stainless steel (SUS303)
4
Brass
20
30
40
0
50
t = 1 mm
10
20
30
Iron
12
Stainless steel (SUS303)
Brass
8
40
50
0
20
40
60
80
Side length of sensing object d (mm)
E2A-M30LN30
Sensing distance X (mm)
E2A-M30KN20
Sensing distance X (mm)
X
16
4
Side length of sensing object d (mm)
Side length of sensing object d (mm)
25
@d
Aluminum
Copper
Copper
2
10
20
Aluminum
Copper
1.0
0
Sensing distance X (mm)
5.0
Sensing distance X (mm)
Sensing distance X (mm)
E2A-S08@N04/M08@N04
@d
X t = 1 mm
Iron
20
15
Stainless steel (SUS303)
10
Brass
35
@d
30
X
Iron
t = 1 mm
25
Stainless steel (SUS303)
20
Brass
15
Aluminum
Copper
Aluminum
10
Copper
5
5
0
20
40
60
80
100
Side length of sensing object d (mm)
0
20
40
60
80
100
Side length of sensing object d (mm)
E2A Cylindrical Proximity Sensor
7
Operation
■ PNP Output
Operation mode
NO
Model
E2A-@-@-B1
Timing chart
Non-sensing zone
Output circuit
Sensing zone
Brown
Proximity
Sensor
+V
Sensing
object
(%)
100
Proximity
Sensor
main
circuits
0
Black
Rated
sensing
distance
(See note 1.)
Load
ON
OFF
ON
OFF
Blue
0V
Yellow indicator
Control output
Note 1: With M8 connector models, there is no output
reverse polarity protection diode.
M12 Connector
Pin Arrangement
(See note 2.)
M8 Connector
Pin Arrangement
4
1
2
4
3
1
3
Note 2: Terminal 2 of the M12 connector is not used.
NC
E2A-@-@-B2
Non-sensing zone
Sensing zone
Brown
Proximity
Sensor
+V
Sensing
object
(%)
100
Black
(M8 connector:
Proximity
Sensor
main
circuits
0
Rated
sensing
distance
Load
ON
OFF
Blue
Yellow indicator
ON
OFF
Control output
Note 1: With M8 connector models, there is no output
reverse polarity protection diode.
M12 Connector
Pin Arrangement
(See note 2.)
M8 Connector
Pin Arrangement
4
1
2
4
1
3
3
Note 2: Terminal 4 of the M12 connector is not used.
8
E2A Cylindrical Proximity Sensor
)
(See note 1.)
0V
■ NPN Output
Operation mode
NO
Model
E2A-@-@-C1
Timing chart
Non-sensing zone
Output circuit
Sensing zone
Brown
Proximity
Sensor
Sensing
object
(%)
+V
Load
100
Proximity
Sensor
main
circuits
0
Rated
sensing
distance
ON
OFF
ON
OFF
(See note 1.) Black
Blue
0V
Yellow indicator
Control output
Note 1: With M8 connector models, there is no output
reverse polarity protection diode.
M12 Connector
Pin Arrangement
(See note 2.)
M8 Connector
Pin Arrangement
4
1
2
3
1
4
3
Note 2: Terminal 2 of the M12 connector is not used.
NC
E2A-@-@-C2
Non-sensing zone
Sensing zone
Brown
Proximity
Sensor
Sensing
object
(%)
+V
Load
100
Proximity
Sensor
main
circuits
0
Rated
sensing
distance
ON
OFF
(M8 connector:
)
Blue
0V
Yellow indicator
ON
OFF
(See note 1.) Black
Control output
Note 1: With M8 connector models, there is no output
reverse polarity protection diode.
M12 Connector
Pin Arrangement
(See note 2.)
M8 Connector
Pin Arrangement
4
1
2
4
1
3
3
Note 2: Terminal 4 of the M12 connector is not used.
E2A Cylindrical Proximity Sensor
9
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Pre-wired Models (Shielded)
E2A-S08KS02-WP-@@
Pre-wired Models (Non-shielded)
E2A-S08KN04-WP-@@
40
40
27
3
13
13
5
27
3
6
5
6 dia.
(See note 1.)
Indicator (See note 2.)
Two, clamping nuts
M8×1
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M12KS04-WP-@@
(See note 1.)
Indicator (See note 2.)
M8×1
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M12KN08-WP-@@
50.3
50.3
34
4
34
17
4
17
7
7
7
9.4 dia.
(See note 1.)
Indicator (See note 2.)
M12×1
(See note 1.)
Indicator (See note 2.)
M12×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M18KS08-WP-@@
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M18KN16-WP-@@
59.5
59.5
39
4
24
10
24
10
39
4
10
15.3 dia.
(See note 1.)
Indicator (See note 2.)
(See note 1.)
Indicator (See note 2.)
M18×1
M18×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M30KS15-WP-@@
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M30KN20-WP-@@
64.5
64.5
44
44
5
36
15
36
10
5
10
26.6 dia.
(See note 1.)
Indicator (See note 2.)
(See note 1.)
Indicator (See note 2.)
M30×1.5
M30×1.5
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
10
E2A Cylindrical Proximity Sensor
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-S08LS02-WP-@@
E2A-S08LN04-WP-@@
62
62
49
49
3
13
13
5
6
5
3
6 dia.
(See note 1.)
Indicator (See note 2.)
M8×1
(See note 1.)
Indicator (See note 2.)
M8×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M12LN08-WP-@@
E2A-M12LS04-WP-@@
72.3
72.3
17
56
17
56
4
7
7
4
7
9.4 dia.
(See note 1.)
Indicator (See note 2.)
M12×1
(See note 1.)
Indicator (See note 2.)
M12×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M18LN16-WP-@@
E2A-M18LS08-WP-@@
81.5
61
81.5
61
24
4
24
4
10
10
10
15.3 dia.
(See note 1.)
Indicator (See note 2.)
(See note 1.)
Indicator (See note 2.)
M18×1
M18×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M30LN30-WP-@@
E2A-M30LS15-WP-@@
86.5
86.5
66
66
5
36
15
36
5
10
10
26.6 dia.
(See note 1.)
Indicator (See note 2.)
(See note 1.)
Indicator (See note 2.)
M30×1.5
Two, clamping nuts
M30×1.5
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Mounting Hole Cutout Dimensions
External diameter
of Proximity Sensor Dimension F (mm)
M8
M12
F
+0.5
8.5 dia. 0
+0.5
0
12.5 dia.
+0.5
0
M18
18.5 dia.
M30
30.5 dia.
+0.5
0
E2A Cylindrical Proximity Sensor
11
M12 Connector Models (Shielded)
M12 Connector Models (Non-shielded)
E2A-S08KN04-M1-@@
E2A-M08KN04-M1-@@
E2A-S08KS02-M1-@@
E2A-M08KS02-M1-@@
43
43
27
3
27
3
13
5
13
M12×1
6
M12×1
5
6 dia.
Indicator (See note.)
Two, clamping nuts
M8×1
Indicator (See note.)
Two, clamping nuts
M8×1
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
E2A-M12KN08-M1-@@
E2A-M12KS04-M1-@@
48
48
34
17
34
7
4
M12×1
17
4
7
7
M12×1
9.4 dia.
Indicator (See note.)
Indicator (See note.)
M12×1
M12×1
Two, clamping nuts
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
E2A-M18KN16-M1-@@
E2A-M18KS08-M1-@@
53
53
39
10
4
24
39
4
10
24
10
M12×1
M12×1
15.3 dia.
Indicator (See note.)
Indicator (See note.)
M18×1
M18×1
Two, clamping nuts
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
E2A-M30KS15-M1-@@
E2A-M30KN20-M1-@@
58
58
44
44
36
5
15
36
10
5
10
M12×1
M12×1
26.6 dia.
Indicator (See note.)
Indicator (See note.)
M30×1.5
M30×1.5
Two, clamping nuts
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
12
E2A Cylindrical Proximity Sensor
Note: Operation indicator (yellow LED, 4×90°)
E2A-S08LS02-M1-@@
E2A-M08LS02-M1-@@
E2A-S08LN04-M1-@@
E2A-M08LN04-M1-@@
65
65
49
49
3
13
5
13
M12×1
M12×1
5
3
6
6 dia.
Indicator (See note.)
M8×1
Indicator (See note.)
M8×1
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
70
E2A-M12LS04-M1-@@
E2A-M12LN08-M1-@@
56
70
56
4
17
7
7
17
M12×1
4
7
M12×1
9.4 dia.
Indicator (See note.)
Two, clamping nuts
M12×1
Indicator (See note.)
M12×1
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
E2A-M18LS08-M1-@@
75
Note: Operation indicator (yellow LED, 4×90°)
75
E2A-M18LN16-M1-@@
61
61
24
4
10
24
10
10
4
M12×1
M12×1
15.3 dia.
Indicator (See note.)
Indicator (See note.)
M18×1
M18×1
Two, clamping nuts
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
80
E2A-M30LN30-M1-@@
E2A-M30LS15-M1-@@
80
66
10
5
15
36
10
5
36
66
M12×1
26.6 dia.
Indicator (See note.)
Indicator (See note.)
M30×1.5
Two, clamping nuts
M30×1.5
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
M8 Connector Models (Shielded)
E2A-S08KS02-M5-@@
M8 Connector Models (Non-shielded)
E2A-S08KN04-M5-@@
39
39
27
27
3
13
5
6
13
M8×1
3
M8×1
5
6 dia.
M8×1
M8×1
Two, clamping nuts
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
E2A-S08LS02-M5-@@
E2A-S08LN04-M5-@@
61
61
49
49
3
13
5
M8×1
6
13
3
5
M8×1
6 dia.
M8×1
Note: Operation indicator (yellow LED, 4×90°)
M8×1
Note: Operation indicator (yellow LED, 4×90°)
E2A Cylindrical Proximity Sensor
13
Precautions
■ Safety Precautions
Wiring
Power Supply
Be sure to wire the E2A and load correctly, otherwise it may be damaged.
Do not impose an excessive voltage on the E2A, otherwise it may be
damaged. Do not impose AC current (100 to 240 VAC) on any DC
model, otherwise it may be damaged.
Load Short-circuit
Do not short-circuit the load, or the E2A may be damaged.
The E2A’s short-circuit protection function will be valid if the polarity
of the supply voltage imposed is correct and within the rated voltage
range.
Connection with No Load
Be sure to insert loads when wiring. Make sure to connect a proper
load to the E2A in operation, otherwise it may damage internal elements.
Do not expose the product to flammable or explosive gases.
Do not disassemble, repair, or modify the product.
■ Correct Use
Power OFF
Designing
The Proximity Sensor may output a pulse signal when it is turned
OFF. Therefore, it is recommended that the load be turned OFF
before turning OFF the Proximity Sensor.
Power Reset Time
The Proximity Sensor is ready to operate within 100 ms after power
is supplied. If power supplies are connected to the Proximity Sensor
and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load.
Effects of Surrounding Metal
When mounting the E2A within a metal panel, ensure that the clearances given in the following table are maintained.
l
Power Supply Transformer
When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with
an auto-transformer.
Mutual Interference
When installing two or more Sensors face-to-face or side-by-side,
ensure that the minimum distances given in the following table are
maintained.
n
m
d dia.
D
l
m
(Unit: mm)
Type
Dimension
M8
M12
M18
M30
Short
barrel
Shielded
Nonshielded
l
0
0
0
(See note 2.)
4.5
12
24
45
d
---
---
27
45
D
0
0
1.5
4
n
12
18
27
45
l
12
15
22
30
40
m
8
20
48
70
90
d
24
40
70
90
120
D
12
15
22
30
40
n
24
40
70
90
120
E2A Cylindrical Proximity Sensor
Dimension
M8
M12
M18
M30
Short Long
barrel barrel
Shielded
Nonshielded
Note 1. In the case of using the supplied nuts.
If true flash mounting is necessary, apply a free zone of
1.5 mm.
2. In the case of using the supplied nuts.
If true flush mounting is necessary, apply a free zone of
4 mm.
14
Type
Long
barrel
0
(See note
1.)
m
(Unit: mm)
A
20
30
60
B
15
20
35
110
70
A
80
120
200
300
300
B
60
100
120
200
300
Wiring
Maintenance and Inspection
High-tension Lines
Periodically perform the following checks to ensure stable operation
of the Proximity Sensor over a long period of time.
Wiring through Metal Conduit:
If there is a power or high-tension line near the cable of the Proximity
Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning.
Cable Extension
Standard cable length is less than 200 m.
The tractive force is 50 N.
1. Check for mounting position, dislocation, looseness, or distortion
of the Proximity Sensor and sensing objects.
2. Check for loose wiring and connections, improper contacts, and
line breakage.
3. Check for attachment or accumulation of metal powder or dust.
4. Check for abnormal temperature conditions and other environmental conditions.
5. Check for proper lighting of indicators (for models with a set indicator.)
Mounting
Never disassemble or repair the Sensor.
The Proximity Sensor must not be subjected to excessive shock with
a hammer when it is installed, otherwise the Proximity Sensor may
be damaged or lose its water-resistivity.
Environment
Do not tighten the nut with excessive force. A washer must be used
with the nut.
Water Resistivity
Do not use the Proximity Sensor underwater, outdoors, or in the rain.
Operating Environment
Type
M8
Torque
Stainless steel type 9 N·m
Brass type
4 N·m
M12
30 N·m
M18
70 N·m
M30
180 N·m
Be sure to use the Proximity Sensor within its operating ambient
temperature range and do not use the Proximity Sensor outdoors so
that its reliability and life expectancy can be maintained. Although
the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or water-soluble machining oil is recommended so that its reliability and life expectancy can be maintained.
Do not use the Proximity Sensor in an environment with chemical
gas (e.g., strong alkaline or acid gasses including nitric, chromic,
and concentrated sulfuric acid gases).
Inrush Current
A load that has a large inrush current (e.g., a lamp or motor) will
damage the Proximity Sensor, in which case connect the load to the
Proximity Sensor through a relay.
E2A Cylindrical Proximity Sensor
15
Warranties, Limitations of Liability
■ WARRANTY
■ LIMITATIONS OF LIABILITY
OMRON’s exclusive warranty is that the products are free
from defects in materials and workmanship for a period of
one year (or other period if specified) from date of sale by
OMRON.
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL,
INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF
PROFITS OR COMMERCIAL LOSS IN ANY WAY
CONNECTED WITH THE PRODUCTS, WHETHER SUCH
CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, REGARDING NONINFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR
PARTICULAR PURPOSE OF THE PRODUCTS. ANY
BUYER OR USER ACKNOWLEDGES THAT THE BUYER
OR USER ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS
OF THEIR INTENDED USE. OMRON DISCLAIMS ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED.
In no event shall responsibility of OMRON for any act exceed
the individual price of the product on which liability is
asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR
WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING
THE PRODUCTS UNLESS OMRON’S ANALYSIS
CONFIRMS THAT THE PRODUCTS WERE PROPERLY
HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE,
OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
■ SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any
standards, codes, or regulations that apply to the
combination of products in the customer’s application or use
of the products.
Take all necessary steps to determine the suitability of the
product for the systems, machines, and equipment with
which it will be used.
Know and observe all prohibitions of use applicable to this
product.
NEVER USE THE PRODUCTS FOR AN APPLICATION
INVOLVING SERIOUS RISK TO LIFE OR PROPERTY
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE
HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND
THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Disclaimers
■ CHANGE IN SPECIFICATIONS
■ DIMENSIONS AND WEIGHTS
Product specifications and accessories may be changed at
any time based on improvements and other reasons. Consult
with your OMRON representative at any time to confirm
actual specifications of purchased product.
Dimensions and weights are nominal and are not to be used
for manufacturing purposes, even when tolerances are
shown.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. D100-E1-01B
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
Sensing Devices Division H.Q.
Industrial Sensors Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7022/Fax: (81)75-344-7107
16
Cat. No. D100-E1-01B
OMRON Corporation
2008.7
In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Rights Reserved.