Artesyn AIH50F300 Total power: 250 watt Datasheet

POWER
AIH Series
250 Watts
Data Sheet
Total Power: 250 Watts
(12 V @ 20.8 A)
Input Voltage: 300 V
# of Outputs: Single
SPECIAL FEATURES
ƒƒ 250 W continuous power at 100 °C
baseplate temperature
ƒƒ High efficiency - up to 88%
ƒƒ Low output ripple and noise
ƒƒ Positive and Negative enable function
ƒƒ Excellent transient response
ƒƒ Safety isolated low voltage control and
monitoring
ƒƒ High reliability
ƒƒ Wide input voltage range
ƒƒ Paralleable with accurate current
sharing
ƒƒ Adjustable output voltage
ƒƒ Regulation to zero load
ƒƒ Temperature monitor output
ƒƒ EU Directive 2002/95/EC compliant for
RoHS
ƒƒ Two year warranty
Input
Input range
250 - 420 VDC
Input surge
450 V / 100 ms
Efficiency*
88% @ 5.0 V (typical)
Output
Load Regulation
60 W for convection; 80 W with 30 CFM forced air
Line Regulation
-5, +10% minimum
Noise / ripple
20 ms @ 60 W load, 115 VAC nominal line
Output voltage adjust range
Short circuit protection on all outputs
Case overload protected @ 110 - 145% above peak rating
5 V output; 5.7 - 6.7 VDC. Other outputs 10% to 25% above
nominal output
Compensates for 0.5 V lead drop min.
Will operate without remote sense connected
Reverse connection protected
Transient response
SAFETY
ƒƒ UL
ƒƒ cUL
ƒƒ TUV
ƒƒ CE
Electrical Specifications
60950 Recognized
60950 Recognized
EN60950 Licensed
CE Mark
Current share accuracy
Overvoltage protection
130% Vo (3.3 Vo and 5 Vo); 125% Vo (other Vo)
Current limit
120% Io maximum
Control
Voltage adjust
80 to 120% for 5 V and above; +10% / -50% for below 5 V
Enable
TTL compatible (positive & negative enable options)
Clock input (external sync)
3.3 to 5.5 Vp-p @ 800 MHz ±5%
Temperature monitor output
10 mV/°K (2.73 = 0 °C)
Current monitor output
0 to 1 mA (1 mA = 100% Io rated)
Note: Nominal values apply with sense pins disconnected and other control pin unconnected.
*For detailed technical information, please refer to the product’s Technical Reference Notes found at
www.Artesyn.com/power.
AIH Series Data Sheet
Environmental Specifications
Operating temperature
-20 °C to +100 °C (case temperature)
Startup temperature
-40 °C to +100 °C (case temperature)
Storage temperature
-40 °C to +100 °C
Overtemperature protection
120 °C max
MTBF
1M hours (Demonstrated)
Ordering Information
Pin Assignments
Input
Output
Control Pins
AIH50Y300
31. Positive
22. Positive
1. +Sense
32. Negative
23. Positive
2. Temp Mon
Input Voltage
Output Voltage
Efficiency
Model Number
300 V
1.8 V @ 50 A
80% (Typ)
300 V
3.3 V @ 50 A
82% (Typ)
AIH50F300
300 V
5.0 V @ 40 A
88% (Typ)
AIH40A300
24. Positive
3. C Mon
4. C Share
300 V
12 V @ 20.8 A
86% (Typ)
AIH20B300
27. Negative
300 V
15 V @ 16.6 A
90% (Typ)
AIH16C300
28. Negative
5. SDA
AIH10H300
29. Negative
6. SCL
300 V
24 V @ 10.4 A
90% (Typ)
7. CLK IN
1. For Negative enable add suffix “N”.
2. Fon Non-thread hole, add suffix “-NT”.
3. Fon RoHS 6, add suffix “-L”. Default is RoHS 5.
8. V Adj
9. Enable
10. -Sense
Mechanical Drawings
WORLDWIDE OFFICES
Americas
Europe (UK)
Asia (HK)
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
While every precaution has been taken to ensure accuracy and completeness in this literature, Artesyn
Embedded Technologies assumes no responsibility, and disclaims all liability for damages resulting from use of
this information or for any errors or omissions. Artesyn Embedded Technologies, Artesyn and the Artesyn
Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other
names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners.
© 2015 Artesyn Embedded Technologies, Inc.
www.artesyn.com
For more information: www.artesyn.com/power
For support: [email protected]
AIH Series-DS 24Mar2015
Similar pages