ON CAT5132 16 volt digital potentiometer (pot) with 128 taps and i2c interface Datasheet

CAT5132
16 Volt Digital
Potentiometer (POT)
with 128 Taps
and I2C Interface
http://onsemi.com
Description
The CAT5132 is a high voltage digital POT with non-volatile wiper
setting memory, operating like a mechanical potentiometer. The tap
points between the 127 equal resistive elements are connected to the
wiper output via CMOS switches. The switches are controlled by a
7-bit Wiper Control Register (WCR). The wiper setting can be stored
in a 7-bit non-volatile Data Register (DR). The WCR is accessed via
the I2C serial bus.
Upon power-up, the WCR is set to mid-scale (1000000). After the
power supply is stable, the contents of the DR are transferred to the
WCR and the wiper is returned to the memorized setting.
The CAT5132 has two voltage supplies: VCC, the digital supply and
V+, the analog supply. V+ can be much higher than VCC, allowing for
16 V analog operations.
The CAT5132 can be used as a potentiometer or as a two-terminal
variable resistor.
Features













Single Linear Digital Potentiometer with 128 Taps
End-to-end Resistance of 10 kW, 50 kW or 100 kW
I2C Interface
Fast Up/Down Wiper Control Mode
Non-volatile Wiper Setting Storage
Automatic Wiper Setting Recall at Power−up
Digital Supply Range (VCC): 2.7 V to 5.5 V
Analog Supply Range (V+): +8 V to +16 V
Low Standby Current: 15 mA
100 Year Wiper Setting Memory
Industrial Temperature Range: −40C to +85C
10-pin MSOP Package
These Devices are Pb-Free, Halogen Free/BFR Free and are RoHS
Compliant
MSOP−10
Z SUFFIX
CASE 846AE
MARKING DIAGRAM
ANBx
YMR
ANBU = CAT5132ZI-10-GT3
ANBK = CAT5132ZI-50-GT3
ANBP = CAT5132ZI-00-GT3
Y = Production Year (Last Digit)
M = Production Month (1-9, A, B, C)
R = Production Revision
PIN CONFIGURATION
1
SDA
SCL
V+
RL
RW
GND
VCC
A1
RH
A0
(Top View)
ORDERING INFORMATION
Device
Package
Shipping†
MSOP
(Pb−Free)
3,000 /
Tape & Reel
CAT5132ZI−10−GT3
CAT5132ZI−50−GT3
Applications
CAT5132ZI−00−GT3






†For information on tape and reel specifications, including part orientation and tape sizes, please refer
to our Tape and Reel Packaging Specifications Brochure, BRD8011/D.
1. For detailed information and a breakdown of
device nomenclature and numbering systems,
please see the ON Semiconductor Device Nomenclature document, TND310/D, available at
www.onsemi.com.
2. The standard lead finish is NiPdAu.
3. For additional package and temperature options,
please contact your nearest ON Semiconductor
Sales office.
LCD Screen Adjustment
Volume Control
Mechanical Potentiometer Replacement
Gain Adjustment
Line Impedance Matching
VCOM Setting Adjustments
 Semiconductor Components Industries, LLC, 2013
July, 2013 − Rev. 7
1
Publication Order Number:
CAT5132/D
CAT5132
VCC
V+
SDA
127
SCL
RH
A1
128 TAP POSITION
DECODE CONTROL
7−BIT
NONVOLATILE
MEMORY
REGISTER
(DR)
7−BIT WIPER
CONTROL
REGISTER
(WCR)
ELEMENTS
A0
127 RESISTIVE
CONTROL LOGIC AND
ADDRESS DECODE
0
RL
Figure 1. Block Diagram
RW
Table 1. PIN FUNCTION DESCRIPTION
Pin No.
Pin Name
1
SDA
Serial Data Input/Output − Bidirectional Serial Data pin used to transfer data into and out of the CAT5132.
This is an Open-Drain I/O and can be wire OR’d with other Open-Drain (or Open Collector) I/Os.
Description
2
GND
Ground
3
VCC
Digital Supply Voltage (2.7 V to 5.5 V)
4
A1
Address Select Input to select slave address for I2C bus.
5
A0
Address Select Input to select slave address for I2C bus.
6
RH
7
RW
Wiper Terminal for the potentiometer
8
RL
Low Reference Terminal for the potentiometer
9
V+
Analog Supply Voltage for the potentiometer (+8.0 V to 16.0 V)
10
SCL
High Reference Terminal for the potentiometer
Serial Bus Clock input for the I2C Serial Bus. This clock is used to clock all data transfers into and out of
the CAT5132
Table 2. ABSOLUTE MAXIMUM RATINGS
Value
Unit
Temperature Under Bias
Rating
−55 to +125
C
Storage Temperature
−65 to +150
C
−0.3 to VCC + 0.3
V
Voltage on any SDA, SCL, A0 & A1 pins with respect to Ground (Note 4)
Voltage on RH, RL & RW pins with respect to Ground
V+
VCC with respect to Ground
−0.3 to +6
V
V+ with respect to Ground
−0.3 to +16.5
V
6
mA
+300
C
Wiper Current (10 sec)
Lead Soldering temperature (10 sec)
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
4. Latch-up protection is provided for stresses up to 100 mA on address and data pins from −0.3 V to VCC +0.3 V.
Table 3. RECOMMENDED OPERATING CONDITIONS
Rating
Value
Unit
VCC
+2.7 to +5.5
V
V+
+8.0 to +16
V
Operating Temperature Range
−40 to +85
C
http://onsemi.com
2
CAT5132
Table 4. POTENTIOMETER CHARACTERISTICS (Over recommended operating conditions unless otherwise stated.)
Limits
Parameter
Symbol
Test Conditions
Min
Typ
Max
Units
RPOT
Potentiometer Resistance (100 kW)
100
kW
RPOT
Potentiometer Resistance (50 kW)
50
kW
RPOT
Potentiometer Resistance (10 kW)
10
RTOL
Potentiometer Resistance Tolerance
Power Rating
IW
Wiper Current
RW
Wiper Resistance
VTERM
Voltage on RW, RH or RL
kW
20
%
50
mW
3
mA
25C
IW = 1 mA @ V+ = 12 V
70
150
W
IW = 1 mA @ V+ = 8 V
110
200
W
GND = 0 V; V+ = 8 V to 16 V
GND
V+
0.78
V
RES
Resolution
ALIN
Absolute Linearity (Note 6)
VW(n)(actual) − VW(n)(expected) (Notes 9, 10)
1
LSB
(Note 8)
RLIN
Relative Linearity (Note 7)
VW(n+1) − [VW(n) + LSB] (Notes 9, 10)
0.5
LSB
(Note 8)
TCRPOT
Temperature Coefficient of RPOT
(Note 5)
TCRatio
Ratiometric Temperature Coefficient
(Note 5)
CH/CL/CW Potentiometer Capacitances
fc
Frequency Response
%
ppm/C
300
30
ppm/C
(Note 5)
10/10/25
pF
RPOT = 50 kW
0.4
MHz
5. This parameter is tested initially and after a design or process change that affects the parameter.
6. Absolute linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a
potentiometer.
7. Relative linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a potentiometer.
8. LSB = (RHM − RLM)/127; where RHM and RLM are the highest and lowest measured values on the wiper terminal.
9. n = 1, 2, ..., 127
10. V+ @ RH; 0 V @ RL; VW measured @ RW with no load.
Table 5. D.C. ELECTRICAL CHARACTERISTICS (Over recommended operating conditions unless otherwise stated.)
Symbol
Parameter
Test Conditions
Min
Max
Units
ICC1
Power Supply Current
(Volatile Write/Read)
FSCL = 400 kHz, SDA Open,
VCC = 5.5 V, Input = GND
1
mA
ICC2
Power Supply Current
(Nonvolatile WRITE)
FSCL = 400 kHz, SDA Open,
VCC = 5.5 V, Input = GND
3.0
mA
Standby Current (VCC = 5 V)
VIN = GND or VCC, SDA = VCC
5
mA
V+ Standby Current
VCC = 5 V, V+ = 16 V
10
mA
ILI
Input Leakage Current
VIN = GND to VCC
10
mA
ILO
Output Leakage Current
VOUT = GND to VCC
10
mA
VIL
Input Low Voltage
−1
VCC x 0.3
V
VIH
Input High Voltage
VCC x 0.7
VCC + 1.0
V
0.4
V
Max
Units
ISB(VCC)
ISB(V+)
VOL1
Output Low Voltage (VCC = 3.0)
IOL = 3 mA
Table 6. CAPACITANCE (TA = 25C, f = 1.0 MHz, VCC = 5.0 V)
Symbol
Parameter
Test Conditions
Min
CI/O
Input/Output Capacitance (SDA)
VI/O = 0 V (Note 11)
8
pF
CIN
Input Capacitance (A0, A1, SCL)
VIN = 0 V (Note 11)
6
pF
http://onsemi.com
3
CAT5132
Table 7. A.C. CHARACTERISTICS
VCC = 2.7 − 5.5 V
Max
Units
Clock Frequency
400
kHz
Noise Suppression Time Constant at SCL & SDA Inputs
50
ns
1
ms
Parameter (see Figure 6)
Symbol
FSCL
TI (Note 11)
tAA
Min
SLC Low to SDA Data Out and ACK Out
tBUF (Note 11) Time the bus must be free before a new transmission can start
1.2
ms
Start Condition Hold Time
0.6
ms
tLOW
Clock Low Period
1.2
ms
tHIGH
Clock High Period
0.6
ms
tSU:STA
Start Condition Setup Time (for a Repeated Start Condition)
0.6
ms
tHD:DAT
Data in Hold Time
tHD:STA
0
ns
tR (Note 11)
SDA and SCL Rise Time
0.3
ms
tF (Note 11)
SDA and SCL Fall Time
300
ns
tSU:STO
tDH
Stop Conditions Setup Time
0.6
ms
Data Out Hold Time
100
ns
11. This parameter is tested initially and after a design or process change that affects the parameter.
Table 8. POWER UP TIMING (Notes 12, 13)
Symbol
Parameter
Min
Max
Units
tPUR
Power-up to Read Operation
1
ms
tPUW
Power-up to Write Operation
1
ms
Table 9. WIPER TIMING
Symbol
tWRPO
tWRL
Min
Max
Units
Wiper Response Time After Power Supply Stable
Parameter
5
10
ms
Wiper Response Time After Instruction Issued
5
10
ms
Min
Max
Units
5
ms
Table 10. WRITE CYCLE LIMITS
Symbol
tWR
Parameter
Write Cycle Time (see Figure 7)
The write cycle is the time from a valid stop condition of a write sequence to the end of the internal program/erase cycle. During the write
cycle, the bus interface circuits are disabled, SDA is allowed to remain high and the device does not respond to its slave address.
Table 11. RELIABILITY CHARACTERISTICS
Symbol
NEND (Note 12)
TDR (Note 12)
Parameter
Reference Test Method
Min
Endurance
MIL−STD−883, Test Method 1033
100,000
Cycles
Data Retention
MIL−STD−883, Test Method 1008
100
Years
12. This parameter is tested initially and after a design or process change that affects the parameter.
13. tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated.
http://onsemi.com
4
Max
Units
CAT5132
TYPICAL PERFORMANCE CHARACTERISTICS
400
12
VCC = 2.7 V; V+ = 8 V
VCC = 5.5 V; V+ = 16 V
10
350
VCC = 5.5 V
300
ICC2 (mA)
RWL (KW)
8
6
4
250
200
VCC = 2.7 V
150
100
2
0
50
0
16
32
48
64
80
96
112
0
−50 −30
128
50
30
70
90
110 130
TEMPERATURE (C)
Figure 2. Resistance between RW and RL
Figure 3. ICC2 (NV Write) vs. Temperature
0.5
0.8
ALIN ERROR (LSB)
0.3
0.4
0.2
0
−0.2
−0.4
−0.6
16
32
48
64
80
96
112
0.2
0.1
0
−0.1
−0.2
−0.3
VCC = 2.7 V; V+ = 8 V
VCC = 5.5 V; V+ = 16 V
0
Tamb = 25C
Rtotal = 10 K
0.4
Tamb = 25C
Rtotal = 10 K
0.6
ALIN ERROR (LSB)
10
TAP POSITION
1.0
−0.8
−1.0
−10
128
−0.4
−0.5
VCC = 2.7 V; V+ = 8 V
VCC = 5.5 V; V+ = 16 V
0
16
32
48
64
80
96
TAP POSITION
TAP POSITION
Figure 4. Absolute Linearity Error per Tap
Position
Figure 5. Relative Linearity Error
http://onsemi.com
5
112 128
CAT5132
tHIGH
tF
tLOW
tR
tLOW
SCL
tSU:STA
tHD:DAT
tHD:STA
tSU:STO
tSU:DAT
SDA IN
tAA
tBUF
tDH
SDA OUT
Figure 6. Bus Timing
SCL
SDA
8TH BIT
ACK
BYTE n
tWR
STOP
CONDITION
Figure 7. Write Cycle Timing
http://onsemi.com
6
START
CONDITION
ADDRESS
CAT5132
SERIAL BUS PROTOCOL
The following defines the features of the I2C bus protocol:
1. Data transfer may be initiated only when the bus is
not busy.
2. During a data transfer, the data line must remain
stable whenever the clock line is high. Any
changes in the data line while the clock is high
will be interpreted as a START or STOP condition.
Acknowledge
After a successful data transfer, each receiving device is
required to generate an acknowledge. The acknowledging
device pulls down the SDA line during the ninth clock cycle,
signaling that it received the 8 bits of data (see Figure 9).
The CAT5132 responds with an acknowledge after
receiving a START condition and its slave address. If the
device has been selected along with a write operation, it
responds with an acknowledge after receiving each 8-bit
byte.
When the CAT5132 is in a READ mode it transmits 8 bits
of data, releases the SDA line, and monitors the line for an
acknowledge. Once it receives this acknowledge, the
CAT5132 will continue to transmit data. If no acknowledge
is sent by the Master, the device terminates data transmission
and waits for a STOP condition.
The device controlling the transfer is a master, typically a
processor or controller, and the device being controlled is the
slave. The master will always initiate data transfers and
provide the clock for both transmit and receive operations.
Therefore, the CAT5132 will be considered a slave device
in all applications.
START Condition
The START Condition precedes all commands to the
device, and is defined as a HIGH to LOW transition of SDA
when SCL is HIGH. The CAT5132 monitors the SDA and
SCL lines and will not respond until this condition is met
(see Figure 8).
Acknowledge Polling
The disabling of the inputs can be used to take advantage
of the typical write cycle time. Once the STOP condition is
issued to indicate the end of the write operation, the
CAT5132 initiates the internal write cycle. ACK polling can
be initiated immediately. This involves issuing the START
condition followed by the slave address. If the CAT5132 is
still busy with the write operation, no ACK will be returned.
If the CAT5132 has completed the write operation, an ACK
will be returned and the host can then proceed with the next
instruction operation.
STOP Condition
A LOW to HIGH transition of SDA when SCL is HIGH
determines the STOP condition. All operations must end
with a STOP condition (see Figure 8).
SCL
SDA
START
CONDITION
STOP
CONDITION
Figure 8. Start/Stop Condition
BUS RELEASE DELAY (RECEIVER)
BUS RELEASE DELAY (TRANSMITTER)
SCL FROM
MASTER
8
1
9
DATA OUTPUT
FROM TRANSMITTER
DATA OUTPUT
FROM RECEIVER
START
ACK DELAY ( tAA)
ACK SETUP ( tSU:DAT)
Figure 9. Acknowledge Condition
http://onsemi.com
7
CAT5132
DEVICE DESCRIPTION
Access Control Register
The next two bits, A1 and A0, are the internal slave
address and must match the physical device address which
is defined by the state of the A1 and A0 input pins. Only the
device with slave address matching the input byte will be
accessed by the master. This allows up to 4 devices to reside
on the same bus. The A1 and A0 inputs can be actively
driven by CMOS input signals or tied to VCC or Ground.
The last bit is the READ/WRITE bit and determines the
function to be performed. If it is a “1” a read command is
initiated and if it is a “0” a write is initiated. For the AR
register only write is allowed.
After the Master sends a START condition and the slave
address byte, the CAT5132 monitors the bus and responds
with an acknowledge when its address matches the
transmitted slave address.
The volatile register WCR and the non-volatile register
DR are accessed only by addressing the volatile Access
Register AR first, using the 3 byte I2C protocol for all read
and write operations (see Table 12). The first byte is the slave
address/instruction byte (see details below). The second
byte contains the address (02h) of the AR register. The data
in the third byte controls which register WCR (80h) or DR
(00h) is being addressed (see Figure 10).
Slave Address Instruction Byte Description
The first byte sent to the CAT5132 from the master
processor is called the Slave Address Byte. The most
significant five bits of the slave address are a device type
identifier. For the CAT5132 these bits are fixed at 01010
(refer to Table 13).
Table 12. ACCESS CONTROL REGISTER
ID2
ID1
ID0
A1
A0
Wb
ACK
ACK
STOP
ST
0
1
0
1
0
0
0
0
A
0
0
0
0
0
0
1
0
A
1
0
0
0
0
0
0
0
A
SP
ST
0
1
0
1
0
0
0
0
A
0
0
0
0
0
0
1
0
A
0
0
0
0
0
0
0
0
A
SP
ACK
ID3
3rd byte
ID4
2nd byte
START
1st byte
AR address − 02h
WCR(80h) / DR(00h) selection
Table 13. BYTE 1 SLAVE ADDRESS AND INSTRUCTION BYTE
Device Type Identifier
Slave Address
Read/Write
ID4
ID3
ID2
ID1
ID0
A1
A0
R/W
0
1
0
1
0
X
X
X
(LSB)
(MSB)
BUS ACTIVITY:
MASTER
S
T
A
R
T
SDA LINE
S
SLAVE
ADDRESS
& INSTRUCTION
AR REGISTER
ADDRESS
WCR/DR
SELECTION
S
T
O
P
FIXED
P
VARIABLE
A
C
K
A
C
K
Figure 10. Access Register Addressing Using 3 Bytes
http://onsemi.com
8
A
C
K
CAT5132
Wiper Control Register (WCR) Description
make use of the 7 LSB bits (The first data bit, or MSB, is
ignored) on write instructions and will always come back as
a “0” on read commands.
A write operation (see Table 14) requires a Start condition,
followed by a valid slave address byte, a valid address byte
00h, a data byte and a STOP condition. After each of the
three bytes the CAT5132 responds with an acknowledge. At
this time the data is written only to volatile registers, then the
device enters its standby state.
The CAT5132 contains a 7-bit Wiper Control Register
which is decoded to select one of the 128 switches along its
resistor array. The WCR is a volatile register and is written
with the contents of the nonvolatile Data Register (DR) on
power-up. The Wiper Control Register loses its contents
when the CAT5132 is powered-down. The contents of the
WCR may be read or changed directly by the host using a
READ/WRITE command after addressing the WCR (see
Table 12 to access WCR). Since the CAT5132 will only
Table 14. WCR WRITE OPERATION
Wb
ACK
0
0
0
A
ST
0
1
0
1
0
0
0
0
0
A
0
0
0
0
1
0
WCR address − 00h
ACK
slave address byte
0
0
0
0
0
0
0
A
1
0
0
0
0
A
0
0
0
0
0
x
x
x
data byte
x
x
x
x
x
STOP
A0
0
A
SP
STOP
A1
1
WCR(80h) selection
ACK
ID0
0
AR address − 02h
ACK
ID1
1
ACK
ID2
0
3rd byte
ACK
ID3
ST
START
ID4
2nd byte
START
1st byte
A
SP
data is low the wiper is decremented at each clock. Once the
stop is issued then the device enters its standby state with the
WCR data as being the last inc/dec position. Also, the wiper
position does not roll over but is limited to min and max
positions.
An increment operation (see Table 15) requires a Start
condition, followed by a valid increment address byte
(01011), a valid address byte 00h. After each of the two
bytes, the CAT5132 responds with an acknowledge. At this
time if the data is high then the wiper is incremented or if the
Table 15. WCR INCREMENT/DECREMENT OPERATION
A0
Wb
ACK
0
0
0
0
A
ST
0
1
0
1
1
0
0
0
0
A
0
0
0
0
1
0
WCR address − 00h
ACK
slave address byte
0
0
0
0
0
0
0
A
0
0
A
1
0
0
0
0
0
0
0
STOP
A1
1
WCR(80h) selection
A
SP
increment (1) / decrement (0) bits
STOP
ID0
0
AR address − 02h
ACK
ID1
1
ACK
ID2
0
3rd byte
ACK
ID3
ST
START
ID4
2nd byte
START
1st byte
1
SP
1
1
1
0
0
0
0
CAT5132 responds with an acknowledge and then the
device transmits the data byte. The master terminates the
read operation by issuing a STOP condition following the
last bit of Data byte.
A read operation (see Table 16) requires a Start condition,
followed by a valid slave address byte for write, a valid
address byte 00h, a second START and a second slave
address byte for read. After each of the three bytes, the
Table 16. WCR READ OPERATION
A1
A0
Wb
ACK
1
0
0
0
0
A
0
1
START
ST
ST
0
1
0
0
0
0
0
A
0
0
0
0
slave address byte
0
1
0
1
0
0
0
0
0
1
0
0
0
0
0
0
X
X
X
data byte
0
1
A
A
1
WCR address − 00h
ACK
slave address byte
0
0
X
X
X
X
http://onsemi.com
9
SP
0
0
0
0
0
0
0
STOP
ID0
0
WCR(80h) selection
ACK
ID1
1
AR address − 02h
STOP
ID2
0
3rd byte
ACK
ID3
ST
START
ID4
2nd byte
START
1st byte
A
SP
CAT5132
Data Register (DR)
written during a write to DR. After a DR WRITE is complete
the DR and WCR will contain the same wiper position.
To write or read to the DR, first the access to DR is
selected, see table 1 then the data is written or read using the
following sequences.
A write operation (see Table 17) requires a Start condition,
followed by a valid slave address byte, a valid address byte
00h, a data byte and a STOP condition. After each of the
three bytes the CAT5132 responds with an acknowledge. At
this time the data is written both to volatile and non-volatile
registers, then the device enters its standby state.
The Data Register (DR) is a nonvolatile register and its
contents are automatically written to the Wiper Control
Register (WCR) on power-up. It can be read at any time
without effecting the value of the WCR. The DR, like the
WCR, only stores the 7 LSB bits and will report the MSB bit
as a “0”. Writing to the DR is performed in the same fashion
as the WCR except that a time delay of up to 5 ms is
experienced while the nonvolatile store operation is being
performed. During the internal non-volatile write cycle, the
device ignores transitions at the SDA and SCL pins, and the
SDA output is at a high impedance state. The WCR is also
Table 17. DR WRITE OPERATION
Wb
ACK
0
0
0
A
ST
0
1
0
1
0
0
0
0
0
A
0
0
0
0
1
0
DR address − 00h
ACK
slave address byte
0
0
0
0
0
0
0
A
0
0
0
0
0
A
0
0
0
0
0
X
X
X
data byte
X
X
X
X
X
STOP
A0
0
A
SP
STOP
A1
1
DR(00h) selection
ACK
ID0
0
AR address − 02h
ACK
ID1
1
ACK
ID2
0
3rd byte
ACK
ID3
ST
START
ID4
2nd byte
START
1st byte
A
SP
acknowledge and then the device transmits the data byte.
The master terminates the read operation by issuing a STOP
condition following the last bit of Data byte.
A read operation (see Table 18) requires a Start condition,
followed by a valid slave address byte, a valid address byte
00h, a second Start and a second slave address byte for read.
After each of the three bytes the CAT5132 responds with an
Table 18. DR READ OPERATION
A1
A0
Wb
ACK
1
0
0
0
0
A
0
1
START
ST
ST
0
1
0
0
0
0
0
A
0
0
0
0
slave address byte
0
1
0
1
0
0
0
0
0
1
0
0
0
0
0
0
X
X
X
data byte
0
1
A
A
0
DR address − 00h
ACK
slave address byte
0
0
X
X
X
X
http://onsemi.com
10
SP
0
0
0
0
0
0
0
STOP
ID0
0
DR(00h) selection
ACK
ID1
1
AR address − 02h
STOP
ID2
0
3rd byte
ACK
ID3
ST
START
ID4
2nd byte
START
1st byte
A
SP
CAT5132
POTENTIOMETER OPERATION
Power-On
~79 W is the resistance between each wiper position.
However in addition to the ~79 W for each resistive segment
of the potentiometer, a wiper resistance offset must be
considered. Table 19 shows the effect of this value and how
it would appear on the wiper terminal.
This offset will appear in each of the CAT5132 end-to-end
resistance values in the same way as the 10 kW example.
However resistance between each wiper position for the
50 kW version will be ~395 W and for the 100 kW version
will be ~790 W.
The CAT5132 is a 128-position, digital controlled
potentiometer. When applying power to the CAT5132, VCC
must be supplied prior to or simultaneously with V+. At the
same time, the signals on RH, RW and RL terminals should
not exceed V+. If V+ is applied before VCC, the electronic
switches are powered in the absence of the switch control
signals, that could result in multiple switches being turned
on. This causes unexpected wiper settings and possible
current overload of the potentiometer. When VCC is applied
the device turns on at the mid-point wiper location (64) until
the wiper register can be loaded with the nonvolatile
memory location previously stored in the device. After the
nonvolatile memory data is loaded into the wiper register the
wiper location will change to the previously stored wiper
position.
At power-down, it is recommended to turn-off first the
signals on RH, RW and RL, followed by V+ and, after that,
VCC, in order to avoid unexpected transmissions of the
wiper and uncontrolled current overload of the
potentiometer.
The end-to-end nominal resistance of the potentiometer
has 128 contact points linearly distributed across the total
resistor. Each of these contact points is addressed by the 7 bit
wiper register which is decoded to select one of these 128
contact points.
Each contact point generates a linear resistive value
between the 0 position and the 127 position. These values
can be determined by dividing the end-to-end value of the
potentiometer by 127. In the case of the 10 kW potentiometer
Table 19. POTENTIOMETER RESISTANCE AND
WIPER RESISTANCE OFFSET EFFECTS
Position
00
70 W or
0 W + 70 W
01
149 W or
79 W + 70 W
63
5,047 W or
4,977 W + 70 W
127
10,070 W or
10,000 W + 70 W
Position
Typical RW to RH Resistance for 10 kW
Digital POT
00
10,070 W or
10,000 W + 70 W
64
5,047 W or
4,977 W + 70 W
126
149 W or
79 W + 70 W
127
70 W or
0 W + 70 W
http://onsemi.com
11
Typical RW to RL Resistance for 10 kW
Digital POT
CAT5132
PACKAGE DIMENSIONS
MSOP 10, 3x3
CASE 846AE
ISSUE O
SYMBOL
MIN
NOM
A1
0.00
0.05
0.15
A2
0.75
0.85
0.95
b
0.17
0.27
c
0.13
0.23
D
2.90
3.00
3.10
E
4.75
4.90
5.05
E1
2.90
3.00
3.10
1.10
A
E
E1
0.50 BSC
e
L
0.40
0.60
L1
0.95 REF
L2
0.25 BSC
θ
MAX
0º
0.80
8º
DETAIL A
TOP VIEW
D
A
A2
END VIEW
c
A1
e
b
SIDE VIEW
q
L2
L
Notes:
(1) All dimensions are in millimeters. Angles in degrees.
(2) Complies with JEDEC MO-187.
L1
DETAIL A
ON Semiconductor and
are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC owns the rights to a number of patents, trademarks,
copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marking.pdf. SCILLC
reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any
particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without
limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications
and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC
does not convey any license under its patent rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for
surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where
personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and
its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly,
any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture
of the part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
LITERATURE FULFILLMENT:
Literature Distribution Center for ON Semiconductor
P.O. Box 5163, Denver, Colorado 80217 USA
Phone: 303−675−2175 or 800−344−3860 Toll Free USA/Canada
Fax: 303−675−2176 or 800−344−3867 Toll Free USA/Canada
Email: [email protected]
N. American Technical Support: 800−282−9855 Toll Free
USA/Canada
Europe, Middle East and Africa Technical Support:
Phone: 421 33 790 2910
Japan Customer Focus Center
Phone: 81−3−5817−1050
http://onsemi.com
12
ON Semiconductor Website: www.onsemi.com
Order Literature: http://www.onsemi.com/orderlit
For additional information, please contact your local
Sales Representative
CAT5132/D
Similar pages