Total Power MIAR03 Dip-24 plastic package Datasheet

MIAR03 SERIES
®
DC/DC CONVERTER 3W, DIP-Package
FEATURES
►DIP-24 Plastic Package
►Cost optimized Design
►Fully Regulated Outputs
►High Efficiency
►Operating Temperature up to +75°C at full Load
►Short Circuit Protection
►Pin compatible with S200R Series
►Input Filter meets EN 55022,class A and FCC, level A
►3 Years Product Warranty
PRODUCT OVERVIEW
The MIAR03 series is a range of isolated 3W DC/DC converter modules featuring fully regulated output voltages and narrow input voltage ranges.Excellent
efficiency allow an operating temperature range of -40°C to +85°C (with Derating).The product comes in a DIP-24 Plastic package with alternative pinout
which makes these converters also a perfect replacement for the popular S200R series.These DC/DC converters offer a very economical solution for many
cost critical applications.
Model Selection Guide
Model
Number
Input
Voltage
(Range)
VDC
MIAR03-05S05
MIAR03-05S12
MIAR03-05S15
MIAR03-05D12
MIAR03-05D15
MIAR03-12S05
MIAR03-12S12
MIAR03-12S15
MIAR03-12D12
MIAR03-12D15
MIAR03-24S05
MIAR03-24S12
MIAR03-24S15
MIAR03-24D12
MIAR03-24D15
5 ±10%
12 ±10%
24 ±10%
Input Specifications
Parameter
Output Current
VDC
5
12
15
±12
±15
5
12
15
±12
±15
5
12
15
±12
±15
mA
600
250
200
±125
±100
600
250
200
±125
±100
600
250
200
±125
±100
Max.
Model
5V Input Models
Input Voltage Range
12V Input Models
24V Input Models
5V Input Models
Input Surge Voltage (1 sec. max.)
12V Input Models
Short Circuit Input Power
Internal Power Dissipation
Conducted EMI
E-mail:[email protected]
2013/01/30 P5
Output
Voltage
@Max. Load
mA(typ.)
857
769
769
769
769
338
316
316
316
316
167
158
158
158
156
@No Load
mA(typ.)
90
45
22
Max. capacitive
Load
µF
470
100
100
100#
100#
470
100
100
100#
100#
470
100
100
100#
100#
# For each output
Min.
4.5
10.8
21.6
-0.7
-0.7
24V Input Models
-0.7
All Models
---
Tel:886-6-2923150
Page 1 of 4
Input Current
---
Typ.
5
12
24
---
---
---
-----
Max.
5.5
Efficiency
(typ.)
@Max. Load
%
70
78
78
78
78
74
79
79
79
79
75
79
79
79
80
Unit
13.2
26.4
7.5
VDC
15
30
2000
2500
mW
mW
Compliance to EN 55022,class A and FCC part 15,class A
MIAR03 SERIES
®
DC/DC CONVERTER 3W, DIP-Package
Output Specifications
Parameter
Output Voltage Setting Accuracy
Conditions
Min.
Typ.
Max.
Dual Output, Balanced Loads
-----
±1.0
±0.2
±3.0
±0.5
At 50% Load and Nominal Vin
Output Voltage Balance
Line Regulation
---
Vin=Min. to Max.
Load Regulation
Io=10% to 100%
Min.Load
---
Short Circuit Protection
Parameter
Conditions
I/O Isolation Voltage (rated)
60 Seconds
I/O Isolation Capacitance
100KHz, 1V
I/O Isolation Resistance
Switching Frequency
MTBF(calculated)
Safety Approvals (pending)
±0.5
---
30
60
Min.
Typ.
Max.
---
---
300
---
1500
---
500 VDC
1000
---
300
MIL-HDBK-217F@25℃, Ground Benign
700,000
---
---
5V Input Models
12V Input Models
Parameter
Operating Ambient Temperature Range (See Power Derating Curve)
Case Temperature
Cooling
---
pF
Output Power (%)
Tel:886-6-2923150
Page 2 of 4
MΩ
KHz
Hours
Max.
Unit
---
+95
℃
95
% rel. H
260
℃
-40
---
Power Derating Curve
Unit
Min.
Free-Air convection
Lead Temperature (1.5mm from case for 10Sec.)
mV P-P
350mA Slow-Blow Type
---
Humidity (non condensing)
%
VDC
---
-50
Storage Temperature Range
E-mail:[email protected]
Conditions
Natural Convection
%
%
24V Input Models
700mA Slow-Blow Type
Environmental Specifications
Unit
%Vnom.
---
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-scheme)
1500mA Slow-Blow Type
2013/01/30 P5
±0.2
Continuous
General Specifications
±4.0
No minimum Load Requirement
Ripple & Noise (20MHz)
Input Fuse
---
+85
+125
℃
℃
MIAR03 SERIES
®
DC/DC CONVERTER 3W, DIP-Package
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
3
All DC/DC converters should be externally fused at the front end for protection.
2
4
5
6
Ripple & Noise measurement bandwidth is 0-20MHz.
Other input and output voltage may be available, please contact factory.
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
Specifications are subject to change without notice.
Package Specifications
Pin Connections
Pin
Single Output
10.2
[0.40]
Mechanical Dimensions
+Vin
3
NC
Common
11
+Vout
+Vout
13
-Vin
2
4.5
[0.18]
10
0.50 [0.02]
3
10
11
12
Bottom View
24
23
15
22
14
12
13
20.3 [0.80]
2
15.22 [0.60]
1
Dual Output
1
NC
-Vout
+Vin
-Vout
Common
-Vin
-Vin
-Vin
14
+Vout
22
NC
Common
+Vin
+Vin
15
23
24
-Vout
NC
+Vout
Common
-Vout
NC: No Connection
31.8 [1.25]
2x2.54
[2x0.10]
2.0
[0.08]
2.54
[0.10]
17.78 [0.70]
2x2.54
[2x0.10]
►All dimensions in mm (inches)
►Tolerance: X.X±0.5 (X.XX±0.02)
X.XX±0.25 ( X.XXX±0.01)
► Pin diameter — 0.5 ±0.05 (0.02±0.002)
Physical Characteristics
Case Size
:
31.8x20.3x10.2 mm (1.25x0.80x0.40 inches)
:
Copper-Clad Steel Wire
Case Material
:
Weight
:
Pin Material
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
12.4g
E-mail:[email protected]
2013/01/30 P5
Tel:886-6-2923150
Page 3 of 4
MIAR03 SERIES
®
DC/DC CONVERTER 3W, DIP-Package
Test Setup
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.33µF ceramic capacitor.
Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC
Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Copper Strip
Scope
Cout
Resistive
Load
Cout
Scope
Technical Notes
Maximum Capacitive Load
The MIAR03 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0Ω at 100 KHz) capacitor of a 4.7µF for the 5V input devices and a 2.2µF for the 12V and 24V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 1.5µF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
+
Cout
Load
-Out
+Vin
DC Power
Source
-
+Out
Dual Output
DC / DC Com.
Converter
-Vin
-Out
Cout
Load
Load
Cout
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 95℃. The derating curves are determined
from measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2013/01/30 P5
Page 4 of 4
Similar pages