MPG-60S Series
Single & Dual Output, 60W
Green, Open Frame
AC/DC Power Supplies
Electrical Specifications
Key Features:
• 60W Output Power
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
• 80W With Only 7 CFM
Input Voltage Range
• Universal 90-264 AC Input
Input Frequency
Input Filter
Input Current
• EN 60950 Approved (UL)
• Meets ErP Directive
• Compact 2 x 4 Inch Size
• Meets EN 55022 B
• Optional +5V SB Output
• >400 kHour MTBF
Conditions
Min.
Typ.
Max.
90
264
110
373
47
63
Meets EN 55022 Class B; FCC Class B
See Model Selection Guide
Cold Start, 115 VAC
30.0
Cold Start, 230 VAC
60.0
0.25
0.5
Universal
Inrush Current
Leakage Current
No Load Power Consumption
Units
VAC
VDC
Hz
A Pk
mA
W
Output
Parameter
Output Voltage/Current
Output Voltage Tolerance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection
Conditions
Min.
Typ.
See Model Selection Guide
See Note 1
±1.0
See Note 2
±1.0
See Note 3
±1.0
See Note 4
±1.0
115 VAC
16
±0.05
140
Continuous (Autorecovery)
Max.
Conditions
Input to Output
500 VDC
Max.
Units
%
%
%
%
mSec
%/°C
%
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
EMI Characteristics
Parameter
Radiated Emissions, See Note 5
Conducted Emissions , See Note 5
ESD
RS
EFT
Surge
CS
PFMF
Voltage Dips, See Note 6
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Switching Frequency
Standard
Min.
3,000
Typ.
100
2,200
Min.
Units
VAC
M⍀
pF
Typ.
Max.
Units
Class B
Class B
Criteria A; ±8 kV Air/±6 kV Contact
Criteria A; 10V/m
Criteria A; ±2 kV Line & PE
Criteria A; L-N: ±1kV, L/N-PE: ±2kV
Criteria A; 10 Vrms
Criteria A; 10 Vrms
Criteria A; Volt. Dips >95%, 0.5 Cycle
Criteria A; Volt. Dips 30%, 25 Cycles
EN 61000-4-11
Criteria A/B; Volt. Dips 60%, 5 Cycles
Criteria B; Volt. Inter, >95%, 250 Cycles
Fixed
65
kHz
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Size
Weight
Conditions
Min.
Typ.
Max.
-20
+25
+70
-40
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
4.00 x 2.00 x 1.20 Inches (101.60 x 50.08 x 30.48 mm)
5.99 Oz (0.170 kg)
Reliability Specifications
Parameter
MTBF
Safety Standards
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
400
UL 60950, EN 60950
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Model
Number
Input
Current (A)
115 VAC
230 VAC
MPG-60S-12
1.50
0.75
MPG-60S-12SB
1.50
0.75
MPG-60S-24
1.50
0.75
MPG-60S-24SB
1.50
0.75
MPG-60S-48
1.50
0.75
MPG-60S-48SB
1.50
0.75
MPG-60D-0512
1.50
0.75
No.
1
2
1
2
1
2
1
2
Voltage
(VDC)
12.0
12.0
5.0
24.0
24.0
5.0
48.0
48.0
5.0
5.0
12.0
Output
Current (A)
Max.
Rated
(W/7 CFM)
5.00
5.00
0.10
2.50
2.50
0.10
1.25
1.25
0.10
3.50
3.50
6.66
6.66
0.10
3.33
3.33
0.10
1.67
1.67
0.10
4.00
5.00
Notes:
1. Output voltage tolerance is measured at 110 VAC input and 60% load.
2. Line regulation is measured at a 115 VAC input with the rated load. The line is varied
±10%.
3. Load regulation is specified for a load change of 60% ±40% (of full load).
4. Output ripple is measured at 20 MHz bandwidth and rated load using 0.1 µF and 10
µF capacitors connected in parallel as close to the power supply terminals as possible.
5. To meet the EMI limits, the mounting holes must be connected together (by using metal
standoffs).
6. The unit meets EN 61000-4-11 criteria A for voltage dips of 60% at 100 VAC input. At
240 VAC input, it meets criteria B.
7. These units will operate at no load without damage. However, they may not meet all
specifications.
8. The optional remote on/off function is active low. Contact the factory for details.
9. Each unit includes an input fuse (250V/2A). Since this fuse is not field replaceable, it
is recommended that an external fuse of the same size be used on the input of the
power supply for protection.
Max Output Power
Min.
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
(W)
Efficiency
Convection With 7CFM
Cooled
Air Flow
60
80
(%, Typ)
87
60
80
87
60
80
89
60
80
89
60
80
90
60
80
90
17.5
42
20
60
87
Derating Curve
Mechanical Dimensions
Connections
Input Connector (CN1):
• Molex 09-65-2038 or equivalent (one pin removed)
• Mating Housing: Molex 09-50-1031 or equivalent
Pin
1
2
3
Function
AC-Neutral
Removed
AC-Line
Safety Ground:
The mounting holes marked “Use metal standoffs” should be
connected to the system earth ground via metal spacers or
a cable. The input side mounting hole marked “FG” provides
the safety earth ground for the unit. This connection should be
locked to prevent possible loosening. Connecting the output side
mounting hole improves EMI.
Output Connector (CN2):
• Molex 09-65-2048 or equivalent
• Mating Housing: Molex 09-50-1041 or equivalent
Pin
1
2
3
4
60S(-SB)
+VOUT
+VOUT
-VOUT
-VOUT
60D
+5V
Grnd
Grnd
+12V
Connector (CN3):
• Molex 22-04-1031 or equivalent
• Mating Housing: Molex 51191-0300 or equivalent
Pin
1
2
3
Function
Remote On/Off
Grnd
+5Vsb
Connector CN3 is only installed on “SB” models
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]