MPD MSR7805-15WUP Effi ciency to 95% Datasheet

MSR7805WUP Series
Low Cost, Non-isolated
UnPotted, Single Output
POL Switching Regulators
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• Efficiency to 95%
• 0.5A Output Current
• Miniature Construction
• EN 60950 Approved
• LM78xx Replacement
• Wide Input Range
• Negative Output Capability
• Short Circuit Protected
• Low Noise
• Low Low Cost
Input
Parameter
Conditions
No-Load Input Current
Min.
Positive Ouput Connection
Input Filter
Typ.
Max.
Units
0.2
1.5
mA
Capacitor Filter
Reverse Polarity Input
Not Allowed, Could Damage the Unit
Output
Parameter
Conditions
Output Voltage Accuracy
Line Regulation
Load Regulation
Typ.
Max.
Units
3.3 VDC Output
Min.
±2.0
±4.0
%
All Other Outputs
±2.0
±3.0
VIN = Min to Max
±0.2
±0.4
%
IOUT = 10% to 100%
±0.4
±0.6
%
Ripple & Noise (20 MHz)
See Note 2
20
75
mV P - P
0.03
%/°C
0.2
1.0
mS
50
250
mV
Max.
Units
850
kHz
Temperature Coefficient
Transient Recovery Time, See Note 3
Transient Response Deviation
25% Load Step Change
Output Short Circuit
Continuous (Autorecovery)
General
Parameter
Conditions
Isolation Voltage
Min.
Typ.
Not Isolated
Switching Frequency
550
EMI Characteristics
Parameter
Standard
Criteria
Level
Radiated Emissions, See Note 4
EN 55022
B
Conducted Emissions, See note 4
EN 55022
B
ESD
EN 61000-4-2
B
±6 kv Air, ±4 kV Contact
RS
EN 61000-4-3
A
10V/m
EFT, See Note 5
EN 61000-4-4
B
±1 kV
Surge, See Note 5
EN 61000-4-5
B
±1 kV
CS
EN61000-4-6
A
3V rms
Environmental
Parameter
Conditions
Operating Temperature Range
MicroPower Direct
Storage Temperature Range
292 Page Street
Suite D
Stoughton, MA 02072
USA
Lead Temperature
Ambient
Min.
Typ.
-40
+25
-55
1.5 mm From Case For 10 Sec
Cooling
Max.
Units
+85
°C
+125
°C
300
°C
95
%
Free Air Convection
Humidity
RH, Non-condensing
Physical
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Size
See Mechanical Diagram (Page 4)
Weight
0.035 Oz (1.0g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
2.0
EN 60950
www.micropowerdirect.com
Max.
Units
MHours
www.micropowerdirect.com
Model Selection Guide
Model
Number
MSR7805-033WUP
MSR7805-05WUP
MSR7805-12WUP
MSR7805-15WUP
Output
Input Voltage (VDC)
Nom.
Range
Efficiency (%, Typ)
Voltage
Current
(VDC)
(mA, Max)
Min VIN
Max VIN
Capacitive
Load
(µF, Max)
24
4.75 - 36.0
3.3
500.0
86
80
680
24
6.50 - 36.0
5.0
500.0
90
84
680
12
7.00 - 31.0
-5.0
-300.0
80
81
330
24
15.0 - 36.0
12.0
500.0
94
91
680
12
8.00 - 24.0
-12.0
-150.0
84
85
330
24
19.0 - 36.0
15.0
500.0
95
93
680
12
8.00 - 21.0
-15.0
-150.0
85
87
330
Notes:
1. For many applications, no external components are required. If the input is over 30V, a 22 µF/50V
input capacitor (C1) is required. See the typical application note below.
2. Output ripple is measured with a nominal input and is specified for a load range of 10% to 100%.
When measuring output ripple, two external capacitors (1 µF and 10 µF) must be placed from the VOUT to
the Gnd pins.
3. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
4. The unit may not meet emissions to class A without the addition of external capacitors (C1, C2 &
C3) as shown in the typical circuit 4 diagram on page 4.
5. The unit meets EFT & surge EMS specifications with the addition of external components as
shown in the typical circuit 4 diagram on page 4.
6. This regulator is not designed to be used in parallel with another unit to increase output power.
7. A reverse polarity connection on the input could damage the unit.
8. The input should not exceed the range given in the model selection chart. Exceeding this limit
could damage the unit.
Fuse
Rating
Slow Blow
(mA, Max
1,000
1,000
1,000
1,000
Derating Curve
Typical Application Circuit 1, Positive Output
For many applications, the MSR7805-xxWUP can
be used without external components. However, if
the application requires meeting EMC/EMI standards or operation at inputs over 30V, a minimum
of external components is needed.
A typical connection (for a positive output voltage)
is shown at right. Here, C1 has been added to
improve stability over the input range (and over
the operating temperature range). Capacitor C2
is added to reduce the output ripple.
Suggested values for these capacitors are given
in the “Component Values” table below. These
capacitors are ceramic and should be placed as
close to the unit as possible. Tantalum or low ESR
electrolytic capacitors may also be used.
If very low noise is required, the LC filter may be
added (LOUT & COUT). The recommended value
for LOUT is 10 µH - 47 µH. For COUT, a 22 µF. is
recommended. To meet EMI standards, see the
typical circuit 4 diagram on page 4.
Model
Number
C1
Typical Application Circuit 2, Negative Output
C2
MSR7805-033WUP 22 µF/50V 22 µF/6.3V
MSR7805-05WUP
22 µF/50V 22 µF/10V
MSR7805-12WUP 22 µF/50V 22 µF/25V
MSR7805-15WUP 22 µF/50V 22 µF/25V
To produce a negative output, connect the output to pin 2
and ground to pin 3, as shown in the diagram above.
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
Typical Application Circuit 3, Pos/Neg Output
Typical application circuit 3 shows two units configured
with a common input connection to produce positive
and negative outputs. The inductor LDM1 is added to
reduce interference between the units. The recommended
values for all the external components are given in the
table at right.
www.micropowerdirect.com
Model
Number
C1/C3
C2/C4
LDM1
MSR7805-033WUP
10 µF/50V
10 µF/6.3V
10 µH
MSR7805-05WUP
10 µF/50V
10 µF/6.3V
10 µH
MSR7805-12WUP
10 µF/50V
10 µF/6.3V
10 µH
MSR7805-15WUP
10 µF/50V
10 µF/6.3V
10 µH
Characteristic Curves, Positive Output
Characteristic Curves, Negative Output
Efficiency vs Input Voltage - (Full Load)
Efficiency vs Input Voltage - (Full Load)
Efficiency vs Output Power - (VIN = Nominal)
Efficiency vs Output Power - (VIN = Nominal)
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
Typical Application Circuit 2: External EMC Components
The diagram above illustrates a typical connection of the MSR7805WUP
series for applications that require meeting EMC standards. Some notes on
this diagram (starting with the input circuit) are:
1. It is recommended that an external fuse be used. The recommended fuse
is shown in the model chart on page 2.
2. An external MOV is recommended on the input to protect the unit in the
event of a surge. A recommended value is given in the table at right.
www.micropowerdirect.com
3. Recommended values for components are:
Component
MOV
LDM1
C3
C4
Value
S20K30
82 µH
680 µF/50V
4.7 µF/50V
Component
LDM2
C1
C2
Value
12 µH
See Note 4
See Note 4
4. The values for C1 and C2 are given in the
“Component Values” table on page 2.
5. The LC filter LOUT & COUT is only needed if very
low ripple is required. Recommended values
for these components are given on page 2.
Mechanical Dimensions
Packing Carton
Pin Connection
Positive Output
Pin
Function
1
+VIN
2
GND
3
VOUT
Negative Output
Pin
Function
1
+VIN
2
VOUT
3
GND
Notes:
1. MSR7805WUP units are shipped in a product carton (inner carton)
which is then paced into a shipping carton. The shipping carton will hold
two product cartons.
2. Products are placed into individual slots cut into foam trays. A foam cover
is then secured to the tray. Each tray will hold 140 units. Up to four trays
will fit into a product carton.
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” on the front of the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]